OK, Paul Wheaton simply doesn't know what he's talking about: "I think that this does produce some savings, but not as much as you might think. If you set your
by dredmorbius 12y ago
OK, Paul Wheaton simply doesn't know what he's talking about:
"I think that this does produce some savings, but not as much as you might think. If you set your thermostat to a constant 70, the heater works a little at a time throughout the day. If you drop it to 50 at night or in the middle of the day, the heater stops working, but then when the time comes to warm the house again, the heater has to work at full power for a long time to get the temp back up - thus losing a lot of your savings."
WRONG WRONG WRONG WRONG WRONG WRONG WRONG WRONG WRONG
Heat losses are driven by two factors:
1. The temperature differential between the hot and cold sides.
2. The thermal conductivity (or exchange) between the hot and cold sides.
That's straight out of Newton's Law of Cooling / Fourier's Law:
http://en.wikipedia.org/wiki/Convective_heat_transfer#Newton.27s_law_of_cooling http://en.wikipedia.org/wiki/Convective_heat_transfer#Newton...
If you're running heat constantly, you're maintaining a constant flow of heat from your interior to the exterior. That is, you're maintaining a high heat exchange rate to the exterior, and you're constantly wasting a large portion of heat.
If you're heating only while you need a warm interior, then as the interior temperature falls, the energy flux to the exterior decreases. You're no longer pumping heat into the external environment.
Yes, you'll run your furnace/heating system continuously for a while in raising the interior temperature, but that is largely adding heat to the interior space, not to the exterior.
The net is expending less energy.
Your most efficient strategy is to turn interior heat down to the minimum essential level (ultimately: enough to keep pipes from freezing), or the minimum level the thermostat allows (often ~50F in the US). My own practice is generally to turn any heating system off entirely at night.
From a moisture management perspective, you also win as cold air has a lower absolute humidity, that is, the quantity of water it can hold is lower. Heating cold humid air reduces the relative humidity, allowing walls and surfaces to dry out.
The overnight heat loss is also a very clear sign that Paul Wheaton is dealing with an exceptionally poorly insulated structure. And a very poor grasp of thermodynamics.
The same principle holds for AC as well, though here you want to increase the temperature setting at which the AC comes on, or disable AC entirely while you're out of the home.
A better way of thinking of this is to minimize the energy input (heating or cooling) when it's not needed.
See:
http://www.uswitch.com/energy-saving/guides/heating-on-all-the-time/ http://www.uswitch.com/energy-saving/guides/heating-on-all-t...
http://www.straightdope.com/columns/read/2970/does-turning-down-the-thermostat-at-night-save-energy http://www.straightdope.com/columns/read/2970/does-turning-d...
http://energy.gov/energysaver/articles/thermostats http://energy.gov/energysaver/articles/thermostats
- Swizec 12y agoFunny how these things have been well solved in places with real winters (or summers) for hundreds of years isn't it? Central European buildings used to have walls so thick as to achieve a cave effect, which gave them nearly constant temperature through most of the year. With some minimal-ish heating during winter as a side-effect of cooking with wood to combat the effect of bad windows.
- fizgig 12y agoNot sure if your comment was a general statement or aimed at the author of the article (Paul), but for the record Montana has "real" winters. I lived a much similar life in rural Utah for many years, doing many of the same lifestyle optimizations that Paul is engaged in. I don't know what Paul's house is built of, but mine was solid brick, which probably matched the structure and function of the dense brick/cob building of Europe. The thermal mass was a blessing, as my only form of central heating was wood/coal-burning cylinder stone in the center of the home. In the dead of winter (lows often in the -5 to -15F range at night), a short, intense burn first thing in the morning would charge the house, with minimal burning during daylight hours to maintain a comfortable temp around the core living areas (55-to-65F). Just before bed, load and tweak the stove for a long slow burn. By morning, even on the coldest of nights, the temp never dropped below 45F. As for his heat-the-person-not-the-room method, that's an obvious, old technique which I applaud Paul for using. For me, a thick down comforter on the bed pre-charged with heat via old-fashioned hot water bottle an hour before (they have nice, newfangled silicone models these days) was all it took. The water was, of course, heated on the wood stove. During the day, wise clothing (layers, wool, hats) and space heating made the place livable. As did the occasional bout of labor to build up head (an old saying is that chopping wood heats you twice). Yes, there is also some acclimation that takes place. Several years after abandoning the lifestyle, I still cannot tolerate indoor temps much warmer than 70. Frankly, given that Paul has a rocket mass heater (much, much more efficient than my stove ever was), I am surprised he needs much in the way of spot-heating. Unless his home is of stick/frame construction.
- lotsofcows 12y agoIn Austria and parts of Germany, rural houses have huge eaves. Wood is collected and stacked under the eaves providing extra thick walls/insulation during the winter.