6 ms·
> “additional efforts are needed to address common technical and market barriers to wider adoption by consumers – which include performance at temperatures of 5
by sokoloff 4y ago
> “additional efforts are needed to address common technical and market barriers to wider adoption by consumers – which include performance at temperatures of 5F and below, installation challenges, and electricity grid impacts during peak demand periods.”
There are definite market barriers at play. In my house in New England, I tried to replace my aged boiler with an air-to-water heat pump (after carefully verifying, via experiments during a cold week in February, that my heat distribution would indeed work fine at a supply of 130°F). Only one company was even willing to come out and provide a quote and their quote was around 2.5x the costs of "put another boiler in", such that the payback period would be "literally never".
If, after doing the research to find out about them and specifically seeking one out, I couldn't manage to make an air-to-water heat pump make sense, I doubt that very many of them are being sold. I suspect it's one of those items that, if more were sold, more firms would sell/install them, bringing the costs into the realm of economically reasonable (and lowering the risk of having a difficult-to-support heating plant in the decades to come).
- CoastalCoder 4y agoMy house uses a heat pump + oil-burning furnace. It gives a pretty good combination of efficiency, and ability to handle really cold weather.
- toomuchtodo 4y agoI think this is most of the way to what the future looks like: a high efficiency heat pump with cogeneration, so you can still burn propane or natural gas for heat and limited power to drive the heating system in an emergency (and if you don't have gas service to the premises, you have either a propane tank [1] or an exterior outlet to hook up outside). You must have a solution for when utility power is down for substantial periods of time. During the winter storm that just passed, a friend in the Midwest called that their house had no power and was rapidly cooling. The utility could provide no ETA to resolution. I walked them through (over the phone) safely enough backfeeding enough power from a gasoline generator (outside, with the extension cord run through a basement escape window) into their furnace circuit to bootstrap the furnace (and run the blower fan) to keep the house warm so that the pipes didn't freeze and burst. If the HVAC system had had a small battery and some way to generate power from the heat it was burning, the gasoline generator would've been unnecessary. Perhaps an integrated thermoelectric generator [2]? A standby generator isn't financially practical for most folks ($6k + install). (EDIT: to the safety folks out there possibly concerned, the furnace breaker and main breaker were tripped, and the meter was pulled to prevent any chance of harm to electrical linemen from inadvertently energizing the utility line; take no chances with safety, do not attempt this at home) [1] https://www.amerigas.com/about-propane/propane-tank-sizes https://www.amerigas.com/about-propane/propane-tank-sizes [2] https://patents.google.com/patent/US5427086A/en https://patents.google.com/patent/US5427086A/en
- Scoundreller 4y agoProblem is high efficiency furnaces/boilers require a powered vent, so they need quite a bit of power to operate. And then you’d need to circulate “cold” air/water against the heat exchangers. This usually adds up to several hundred watts.
- sokoloff 4y agoFor others interested in preparing for a situation like this, here's a video laying out in reasonable detail what to do.* https://www.youtube.com/watch?v=1JNuovFpCpQ https://www.youtube.com/watch?v=1JNuovFpCpQ * I don't like that they skipped putting a bushing or an NM clamp on the back of the box into the furnace, but otherwise the video looked sound when I watched it a couple weeks ago.
- jchw 4y agoI've been waiting to do this in the event of a power outage; that said, I'm really curious what the current draw of my furnace blower will wind up being. There is a label that suggests it has a peak draw of 8.5A, but that seems like a lot. Still, it seems like a nice backup plan in the event of an outage, even if I only have a couple kWh worth of battery storage.
- a9h74j 4y agoMany furnaces use third-party controller boards with well-known suppliers. You might find in the furnace manual that there are different wire-to-board permutations to allow different fan (interior recirculating blower) speeds. From home testing a few years ago, I recall RMS currents 50%-80% of peak rated draw, but could be mistaken.
- mikeyouse 4y agoWhat's the model number of your furnace / blower? I've been doing a ton of research in this area as I'm remodeling my place and have several furnaces and duct loops to deal with. From what I've seen so far, unless your unit is super old, the 8.5A is almost certainly just a 'peak' startup current that's overstated as well. Your blower should say something like "1/3 HP" and from there it's straightforward conversion of 1HP = ~750W so a 1/3HP would be 250W. On a 120v service, that's 2 Amp. With maybe 15% efficiency loss, at peak speed, the blower motor wouldn't be drawing more than 2.5A. It could/will draw more than that to start, but literally just for a second or two.
- wmeredith 4y agoMine is the same with a gas furnace/heat pump combo. It's great.
- jcadam 4y agoMy house uses a NatGas boiler and in-floor radiant heat. It also has wood stoves for those -20F (or worse) nights when I need a little supplemental heat (or the power is out and the main heating system is offline). A heat pump would be a waste up here in Alaska esp given I don't need A/C. Just opening the windows and running some fans in the summer tends to do the trick for cooling.
- throw0101c 4y ago> Just opening the windows and running some fans in the summer tends to do the trick for cooling. The problem with 'natural' ventilation is you also get things humidity, pollen, dust, etc coming in as well. One of the major advantages of mechanical ventilation (like HRV/ERVs, which cycle the air) is that things are tempered and filtered beforehand. Sometimes you also want to deal with individual variables: the temperature is fine, but the humidity is off.
- jcadam 4y agoThere's the expense of maintaining a central A/C, ductwork, etc., that I'd rather not deal with (not to mention electricity is expensive here). Yes, if the air outside is dirty (forest fires, volcanic eruption, etc.) you've got a point. HEPA filters can help some with this, I suppose. Humidity isn't usually a big issue here most days. If anything, it can be a bit dry (but not as dry as running an A/C would make it). Though, I do have a portable dehumidifier I use when I need to :)
- a9h74j 4y agoIs filtering incoming air (for a mix) necessarily the norm, though? Even in the rare high-performance homes built on spec[ulation], my sense is that filtering incoming air might be omitted, in favor of a single filter acting on recirculation.
- jcadam 4y agoAnd forced air can be quite dirty (dust/pollen/etc.) if you don't clean your ducts regularly.
- euroderf 4y agoMy use case is similar. The oil furnace feeds hot water into a network of radiators. My design goal is to maximize the electricity outage that we can make it thru without frozen pipes, and it has to be on a budget (so no generator or giant UPS). The house is mostly unoccupied (a second home). Operation in an outage has to be fully automatic - it needs an automatic transfer switch I guess. The typical indoor temperature is just 5.5C (42F) - this does not leave much margin for the house to cool down during an outage when outside is like -5C (or -10 or -20). But it turn out that an oil pump and a water circulation pump do not draw THAT much power, so if I can run them off backup power (say, a new car battery plus an inverter), it should last for some time before ice has any chance to form.
- pridkett 4y agoI’ve got the same thing. I did a bunch of tests last year to figure out relative performance and costs of heating my house at various outside temperatures. This included doing fine grained electricity monitoring with an iotawatt and rough fuel oil usage using an ultrasonic sensor. Of course, now I’ve got a ton of data that I haven’t finished building my automation with. And, unfortunately, I’ve got an annoyingly bad Lennox iComfort for my heat pump thermostat and may have troubles building the automation anyway.
- linuxftw 4y agoI recently spoke to a well driller that also does geothermal well drilling. He was telling me that the systems are more or less obsolete at this point, as the air-to-air units have such a high SEER rating that the ground loops really will never pay off.
- benmanns 4y agoIs geothermal any quieter? I was assuming the ground loop pump would be quieter than the air-to-air fan.
- sokoloff 4y agoThere's no outside noise in a ground-source system (for all practical values of noise: it's just flow in insulated pipes). The pumps are nearly inaudible inside the mechanical room as well. Inverter-based air-source outdoor units are nearly inaudible during any time when your neighbors are likely to have their windows open. When the weather is uncomfortable enough to have the units need to run at high-speeds, they are no longer inaudible, but the neighbors are likely to have their windows closed.
- zacharycohn 4y agoI'm looking at a system now that is 45 decibels - 10db quieter than my robovacuum which is one of the quietest in the market.
- implements 4y agoWhat attracted me to geothermal was the year round availability of 50F water - easier to extract winter heat at that temperature, and you could create a simple fan / radiator ducted air cooling system for the summer. The latter would actually store summer heat in the ground, and could be powered purely by solar.
- Bedon292 4y agoI have been doing a bunch of research into geothermal recently and this doesn't seem to match with what I have seen. But it probably also varies a lot by location and such. They appear to still be about twice as efficient as an air to air one, and have less parts and maintenance (no outside unit to deal with). Yes the initial install is a lot higher because of the drilling but that should last for decades. In the US there is also 30% rebate at tax time which helps cut the costs down a bunch too.
- lizknope 4y agoI watch the PBS show This Old House which takes place in the Boston area. The plumber / HVAC guy Richard Trethewey is a fan both ground ("geothermal") and air source heat pumps including the air source heat pumps that work at 0F and heat water for radiant floor heating. I'm surprised that more companies aren't doing it there.
- maxerickson 4y agoThe majority of their projects are pretty high end (and they tend to want to demonstrate new technology, because it's more interesting).
- throw0101c 4y agoFor the 'project homes', perhaps, but if you're going to go through the effort of building new or re-doing an entire structure, you might as well use the latest and greatest stuff/practices/code. They also have many segments of smaller DIY jobs for simpler fixes/maintenance, e.g.: * https://www.thisoldhouse.com/plumbing https://www.thisoldhouse.com/plumbing
- lazide 4y agoThey most likely get funding (in the form of steep discounts or free equipment) from the equipment manufacturers to do those installs. They’re called demo homes in the trades. It’s a good way to buy a bunch of headaches if you do it on your own without manufacturer support.
- panzagl 4y agoThe 'cast' of 'This Old House' is mostly MIT MechE grads who figured out they could make more money doing renovations for Route 128 techies than burning themselves out working at their companies.
- throw0101c 4y agoOh yeah, Richard Trethewey and Tom Silva are definitely MIT guys: * https://www.thisoldhouse.com/21071273/richard-trethewey https://www.thisoldhouse.com/21071273/richard-trethewey * https://www.thisoldhouse.com/21071309/tom-silva https://www.thisoldhouse.com/21071309/tom-silva * https://www.thisoldhouse.com/cast https://www.thisoldhouse.com/cast
- ableal 4y ago> their quote was around 2.5x the costs of "put another boiler in", such that the payback period would be "literally never". Doesn't that depend on the costs of both energy sources? Last year I made a similar choice, albeit at smaller scale, just for one water heater. Picked an electric heater with heat pump, also cost 2.5x more than plain electric, but 1/3 the energy cost. It will take a few years to pay back ...
- sokoloff 4y ago> Doesn't that depend on the costs of both energy sources? Yes, it depends on the costs and efficiencies of the competing energy sources, the difference in capex, the annual building heat load, the projected lifespan of each source, annual maintenance costs, and the interest rate.
- dashundchen 4y agoWas it a company that also did gas boilers? If it's not a company that solely does heat pumps, I have heard a lot of contractors will give outrageous estimates because gas is simpler for them and they don't want to do it without the huge markup. I had ground source heat pump installed with vertical wells in a city by a dedicated geo installer. The cost with tax credits came out not much more than a high end gas furnace and water heater. Going airsource would have been even more cost competitive, especially with the federal tax credits in place starting in 2023.
- sokoloff 4y agoThey did. To (only partially) guard against that, I made it clear that I wouldn’t be hiring them to hang a gas boiler. (That still allows them to prefer someone else’s gas boiler job over my air-source job, but at least prevents me bidding against myself.) And there definitely would be more labor, more piping, and more electrical work to switch to an ASHP; that’s part of the market forces problem that is hard to overcome with anything other than large price increases for gas or larger direct subsidies for switching.
- chris222 4y agoWas it the company mentioned in the second half of this show: https://youtu.be/TlX5z32T1J4 https://youtu.be/TlX5z32T1J4 Air to water is pretty new technology for the U.S. As you mentioned most oil boiler hydronic systems are spec’d for a much higher temp (like 160 to 180F). I’ve been curious myself if you can salvage any of the existing baseboards with a 130F supply. I have a 5 head mitsubishi cold weather mini split installed last year but I am still keeping my oil boiler for now for domestic hot water and supplemental heat. If I could switch that to an air to water heat pump for a reasonable cost that would be nice.