In addition to a heat pump, I wish my HVAC had a filtered vent from the outside and would be intelligent enough to sometimes just pump in cooler or warmer air f
by Waterluvian 4y ago
In addition to a heat pump, I wish my HVAC had a filtered vent from the outside and would be intelligent enough to sometimes just pump in cooler or warmer air from the outside when viable.
I don’t like having to shut off my furnace and manually manage windows. But I also don’t want automatic windows. I just want it to be like, “you’re asking for 21C and we can get there by pumping in outside air rather than using an AC to transfer heat from the inside air to the outside air.”
- bombcar 4y agoThere are machines that do just that. They’re descended from commercial units, and you have to match humidity, but they can be done. It’s just not been worth the cost, usually.
- bofh23 4y agoThis “Smart Window Fan” is a window-mounted economizer. If it’s cooler and dryer outside, like at night, it opens its louvers and pulls in cool air and exhausts warm air. It also has a HEPA filter. I assume it has humidity sensors too to avoid running when it’s humid outside. I am wary of a product sold by only one vendor. Economizers tend to be added to large central ducted commercial HVAC systems and this is the only window unit I’m aware of. EcoBreeze 2.2 - Nature's Cooling Solutions® https://naturescoolingsolutions.com/ecobreeeze-2/ https://naturescoolingsolutions.com/ecobreeeze-2/
- Dig1t 4y agoYou must have a well insulated house.. as soon as I turn off my AC or heater my house very quickly becomes the same temperature as outside..
- ghaff 4y agoReally? I live in a mostly not very well-insulated 200 year old wood construction farm house and I find that there can easily be a 10 degree F delta between indoors and outdoors. I have heat for the winter given northern climate but otherwise mostly just do regulation by opening or closing windows.
- deleted 4y ago[deleted]
- shusaku 4y agoYour house was built before the days of A/C so the builders probably deserve more credit!
- Waterluvian 4y agoMy house is also in a forest so the sun doesn’t bake it. That might be part of it.
- dijonman2 4y agoIt’s called an economizer and is controlled by enthalpy sensors. Look into honeywell jade system, if you are handy then you can DIY it. Controllers are super cheap on ebay. Just be mindful of air balance.
- elil17 4y agoThat’s called an air side economizer, they’re very common in commercial buildings but residential units are also available.
- mherdeg 4y agoYeah it makes me really upset when the outside dew point is lower than inside (often in the fall) and I've got to dig out my lasko box fan and run it in the windows. There are several kinds of HVAC systems for fresh air ventilation and free cooling (HRV/ERV) and it was a huge bummer to hear an ac expert say "your tiny house's tiny closet has no space for any new toys at all"
- Jill_the_Pill 4y agoNot to be really dumb about this (I don't have a heat pump, don't know exactly how they work, but have some interest in getting one) -- is it not possible to shut them off entirely for the fall? Are they hard to restart or something? Is it like the obnoxious car systems that always want to be giving you either heat or cool and just refuse to do nothing when it's nice out?
- sokoloff 4y agoThey can easily turn themself off and restart easily. GP was wanting to take advantage of the more favorable outside air (lower sensible and latent heat) and just do filtered air exchange directly with the outside rather than running the compressor.
- masklinn 4y ago> In addition to a heat pump, I wish my HVAC had a filtered vent from the outside and would be intelligent enough to sometimes just pump in cooler or warmer air from the outside when viable. Hell a modern AC can probably do with only filtered venting, with a heat exchanger which gets disabled when using external air to get to the target temperature.
- bilsbie 4y agoYou should look into a whole house fan.
- tolmasky 4y agoWe installed something like this, but for the purpose of getting fresh air into the house (instead of circling stale air over and over and increasing the CO2 levels). Our setup is: Fresh air / circulated air -> Perfect 16[1] -> HVAC I highly recommend it. You can also get an ERV or HRV to utilize heat/humidity when bringing in outside air. 1. https://www.iqair.com/us/whole-house-air-purifiers https://www.iqair.com/us/whole-house-air-purifiers
- piceas 4y agoI think systems like this make sense. I'm not yet convinced that they are worth 3k more than a pico and a fan, at least as a retrofit.
- pkulak 4y agoThe beauty of a real ventilation system is the heat exchanger. I’m still waiting for someone to make one that I can run by feeding a tube out my window, but until then, you need to spend a bit of cash on a permanent installation.
- WithinReason 4y agoI was looking for such a minified heat pump as well, no luck.
- Scoundreller 4y agoOr just, a windowshaker A/C unit that has a heat mode. (That’s uglier, but surprisingly difficult to find).
- WithinReason 4y agoExactly, but no luck. Maybe there is a technical reason.
- 4y ago
- smileysteve 4y agoThe cheap DIY is to add WiFi switches to your bathroom fans, turn them on when humidity is lower outside or when the outside is cooler than the inside.
- fennecfoxen 4y agoWiFi? Eh. As an ever-so-modest upgrade to the cheap DIY, a Zwave or Zigbee system might be a better choice to integrate with a variety of other things (like thermostats and temperature/humidity sensors.)
- Nextgrid 4y agoWi-Fi is easier to interface with using any computer, where as those other protocols require a dongle on the computer side.
- pkulak 4y agoSure, but once you have 20 or 30 of those things in your walls, congesting up your network, you’ll wish you went with something that runs at 900 mhz.
- benj111 4y ago>20 or 30. In my house. 9 X main lights. Kitchen work lights. Extractor fan. Oven Hob (gas) Dishwasher Washing machine Dryer. Fridge. Freezer. Food processor Kettle Toaster. TV. Digi box PlayStation (2 but anyway) Extractor fan Boiler Laptop Printer 5 X lamps. So I managed to get to 30 things. I'm not entirely sure I'd want to hook up all those things to a network though...
- bmicraft 4y agoZigbee also runs on 2.4GHz, but I wouldn't even count WiFi out just yet since those devices are on 2.4GHz where latency and throughput are almost irrelevant (to me) for that application. Plus it's usually cheaper.
- JohnJamesRambo 4y agoI think the main problem would be humidity issues. The outside air swings so wildly in humidity. I was growing weed outside in my state and surprised to watch the humidity on the meter regularly go from 21% to nearly 100% on day night cycles.
- amluto 4y agoLook at dew point or some absolute humidity measure instead. As air gets colder, the amount of water vapor it can hold (the denominator in relative humidity) decreases dramatically. Introducing cold, saturated air to your warm house will not, in general, make it feel nasty and humid.
- JohnJamesRambo 4y agoSome googling of experts shows it can be quite a concern. https://www.eng-tips.com/viewthread.cfm?qid=188008 https://www.eng-tips.com/viewthread.cfm?qid=188008
- Scoundreller 4y agoI can only barely understand what’s going on in that link, but I think it really depends on target indoor environment. While I don’t want the walls sweating, I could imagine there are industrial or commercial environments where moisture level matters a lot. Electronics plant: dry is always bad! Want some moisture to dissipate static. A library wants low, but not zero moisture. A manufacturing plant wants it to be very consistent. A fruit market wants its humidity high. In a residential environment, it’s a toss up: some stuff wants to be dryer while other stuff doesn’t.
- amluto 4y agoI don’t think you’re likely to make the walls sweat by running an economizer or, for that matter, opening a window while it’s cooler outside than inside. You may end up with more humidity inside than you like, though, depending on the weather. That link seems to be discussing a situation where there is too much humidity coming in relative to the amount of heat the A/C needs to remove, and that hits my pet peeve about air conditioning design. Air conditioners generally run at a roughly constant coil temperature, which means that there is no independent control over dehumidification versus cooling. If you happen to be at the design conditions, great. Otherwise you don’t end up with the humidity you want. I know of one system (“dynamic humidity control” by Chiltrix) that adjusts the coil temperature to control humidity. As far as I know, any hydronic system can do this with minimal modification, but I don’t think it’s popular.
- deleted 4y ago[deleted]
- dagmx 4y agoIsn’t that effectively a heat recovery ventilation system? https://en.wikipedia.org/wiki/Heat_recovery_ventilation?wprov=sfti1 https://en.wikipedia.org/wiki/Heat_recovery_ventilation?wpro...
- caf 4y agoYes - these are necessary in houses designed to minimise air leakage, because without them they can end up so well sealed that they do not allow enough air changes per hour.
- tempestn 4y agoThat's kind of the flipside of what OP is describing. OP is saying if it's colder outside than inside, and you want it to be colder inside, the unit would intelligently just pull in unprocessed (except filtering) outside air. An HRV or ERV is designed to pull in fresh air without losing heat from inside (or while keeping the heat outside in the summer), by transferring heat between the air being drawn in and that being exhausted.
- stephen_g 4y agoYou can get this in a lot of places, with units that use the inside air to pre-condition the outside air being brought in so you're not destroying the efficiency of your HVAC system. It's called Heat Recovery Ventilation (HRV) or Energy Recovery Ventilation (ERV). Units exist for small residential buildings all the way up to massive commercial units. HRV is used in temperate climates where the humidity outside is generally not a problem, and ERV is used when the outside air needs to be dehumidified also. It's not usually a feature of residential units, but commercial ones also have a bypass for when the building management system detects (using sensors like wet-bulb thermometers) that the outside conditions are fine to bring inside, which is called the "economy cycle". It switches off the baffles to the HRV or ERV and just brings the outside air in directly. If somebody was really interested, that could be implemented at home with some extra ducting, some controllable dampers, sensors, a Raspberry Pi, etc.
- tempestn 4y agoOne thing to remember is that when the air outside is already warmer than the air you want to heat or cooler than the air you want to cool, this will significantly increase the efficiency of the heat pump in achieving that temperature. I would guess to the point where it's not worth complicating the system in this way. (Especially since it will be a relatively rare compared to the reverse situation.)
- hedora 4y agoHi! We're idiots, and just built a house without paying extra for the automatic window openers. In fairness, said openers wouldn't be able to talk to our proprietary thermostat. The heat pump we bought is great, though.
- porknubbins 4y agoThats an interesting idea. Where I live I think you would have to have significantly colder air outside to compensate for the humidity of just bringing in outside air, unless if could be dehumidified. I think there would be a limited window of usefulness.