4 ms·
Original paper: doi: 10.1002/anie.201302577 From their paper it is mentioned they have a 40 nanolitre/min flow rate (25% desalination rate, 99% is considered s
by haldujai 13y ago
Original paper: doi: 10.1002/anie.201302577
From their paper it is mentioned they have a 40 nanolitre/min flow rate (25% desalination rate, 99% is considered safe to drink water).
They use an electric pole to generate an ion depletion zone, their problem right now lies in the severely limited flow rate and desalination rate. From my understanding the 25% desalination rate does not compound linearly and decreases in efficiency as the concentration of salt ions decreases.
Additionally their flow rate is 0.4 microlitres per minute, this would equate to needing 625 000 channels for one pass only to get 250mL / min. Scaling for microfluidics isn't simply using a larger pipe size, microfluidic devices largely operate with minimal forces and a Reynolds number of 1, that doesn't hold as you get larger.
The other big problem here is that this requires pressure driven flow, to do that they made two reservoirs of uneven height on opposite ends to drive flow. Again this is very electrically cheap (picowatts) when dealing with such small and perfect flow conditions.
The biggest problems they need to address are the low filtration rate and the low flow rate, it does not seem like there is a simple answer to the first, they do state that they are conducting a larger scale experiment that they will publish later.
I largely suspect that the larger scale experiment will fail in efficiency as another group (doi:10.1038/nnano.2010.34) who also uses a ion depletion zone (albeit by a different mechanism) found after publishing that they were orders of magnitude (10^3) too low in their predictions.
If anything this will perhaps be better than small, portable RO setups but not replace large factories which are actually pretty efficient.
- rflrob 13y ago>Additionally their flow rate is 0.4 microlitres per minute, this would equate to needing 625 000 channels for one pass only to get 250mL / min. Scaling for microfluidics isn't simply using a larger pipe size, microfluidic devices largely operate with minimal forces and a Reynolds number of 1, that doesn't hold as you get larger. What about parallelization? Are there any obvious downsides to simply having lots of the active units, aside from the (what seems to me largely manageable) increase in micro fluidic chip complexity?
- sbierwagen 13y agoUsing 625 000 channels is parallelization. Those channels are in parallel.
- haldujai 13y agoYes, parallelization is actually the currently accepted means of increasing throughput, you'll see diagnostic devices with thousands of channels. The reason it isn't appropriate here is because of the complexity, the design is easy, you make a radial pattern of inlets with the splits towards the middle so you can combine outlets of the same type. Construction is relatively easy as well. The problem comes from the number of inlets. You can: a) a common inlet to all of your channels, or b) independent inlet for each channel, or for several channels a) might seem intuitive, the problem is limitations on channel width, the inlet would have to feed a single channel which would then split (they would split to the inlet channel from the paper), structural limitations of PDMS and manufacturing have maximum widths and heights in millimetres at best. Which would not be enough to achieve the throughput required. The original 'master' inlet would probably have to be at least in the 10-20 cm range to achieve flow rates that could make this a household filter. Even with another, stronger material, and perhaps manufacturing techniques I'm not aware of you still have limitations of pressure, their channels are very small in the paper (for a reason), pressure becomes a limiting factor to prevent their failure. The problem with b is sheer complexity, you're talking about 10 000 tubes and connectors and holes punched into a chip if you even do a 1 - 60 split. The chip with just the channels would be about the size of a tissue box, this wouldn't be able to accomodate the channels so now you're talking about something tens of metres x tens of metres. This is hugely cost prohibitive and the channels from connectors would have to be really long, really long channels need more pressure to drive the liquid requiring more energy which reduces the efficiency significantly. The reason parallelizaton works in pharmaceutical / DNA testing applications is you're going from microlitres of DNA/samples to nano, or picolitres in the channels, a single inlet can sufficiently provide that throughput (you're talking 10 uL / hour perfusion rates) Edit: TL;DR version: Construction constraints would make this have worse efficiency than reverse osmosis and cost a lot more to manufacture as well.
- Retric 13y ago