I added a non-wi-fi Mitsubishi AC to Home Assistant
- akifbayram 2mo agoI’ve been working on a similar setup using the M5Stack NanoC6 and AtomS3 Lite, and put together a parts list and wiring guide on my site: https://serin-labs.com/parts.html https://serin-labs.com/parts.html. I also built a web flasher with firmware configured for those boards, so you can install directly from your browser without any fiddling or configuring. The ESPHome option uses the same echavet/MitsubishiCN105ESPHome project mentioned in the article. I also included a YAML generator for that project so you can more simply customize the config. There are also separate firmware options for HomeKit and Matter. https://serin-labs.com/flash.html https://serin-labs.com/flash.html https://serin-labs.com/esphome/generate-yaml.html https://serin-labs.com/esphome/generate-yaml.html I run Serin Labs and sell assembled kits and the cable separately. For anyone with City Multi, P series, or M series systems with a branch box, you may also be interested in a multi zone controller I’m developing: https://serin-labs.com/multi-zone-controller.html https://serin-labs.com/multi-zone-controller.html. It connects to the system’s communication bus, allowing one device to control all zones without needing a CN105 adapter at each indoor unit. It also exposes operating data such as refrigerant pressures, temperatures, power, compressor frequency, and fault codes, with everything running locally. Software is still in development.
- cgrin 2mo agoThe Nano is fine to connect directly because it has diodes on the data pins but the S3 Lite needs a level shifter or it'll eventually stop communicating with the air handler.
- micromacrofoot 2mo agoyeah came here to say this, I have my mini splits set up on the S3 light with level shifters, not worth skipping because they'll end up failing on you - requires a little soldering but nothing complicated wiring: 1. Mini split black (GND) → ATOM G 2. ATOM spare G → shifter GND (either row) 3. Mini split red (5V) → ATOM 5V 4. ATOM spare 5V → shifter HV ref 5. ATOM 3V3 → shifter LV ref 6. Mini split yellow → shifter HV1 7. Shifter LV1 → ATOM (G2 / GPIO2) 8. Mini split white → shifter HV2 9. Shifter LV2 → ATOM (G1 / GPIO1) if the gpio ends up being reversed you can handle it in software
- hanrelan 2mo agoHN is awesome sometimes, I actually just installed 3 of your devices in my ACs to get them all wifi enabled. Worked perfectly, thank you! Is it possible to flash them from Google home firmware to esphome without USB? I might move away from Google home soon but I'd hate to have to reopen up my ACs again.
- akifbayram 2mo agoAwesome. I'm glad to hear that. It's not possible to cross-flash a different firmware track over the air but since you're already using the Matter-compatible firmware, you can pair it directly with Home Assistant, fully local. It won't be as configurable as the ESPHome firmware, but it'll get you the controls you need.
- doug_life 2mo agoThanks. I’ve been looking for a clean ots solution and somehow managed to not come across your company yet. Just purchased pre-assembled module!
- wangxin199 2mo ago[flagged]
- DANmode 2mo ago> I also built a web flasher with firmware configured for those boards, so you can install directly from your browser without any fiddling or configuring Awesome
- hatsix 2mo agoI've got four units already hooked up with esphome, but the branch box diagnostics is what I need... the unpredictable nature of multi zone units is infuriating. Why is one room 10 degrees above it's set point and still pumping out heat? I've got my own devices and can make my own cables, if you're looking for someone to test things out
- akifbayram 2mo agoFrom what I've read and experienced over the years, the indoor units of a Mitsubishi multi zone system never fully close their valves, so refrigerant flows through them even when they aren't actively heating or cooling. This becomes a problem when the indoor unit also runs the fan non-stop to get an accurate reading of the room temperature, since a thermostat with a remote temperature reading typically isn't available. I got around this by disabling the fan from blowing when the indoor unit isn't actively calling for refrigerant. The refrigerant still flows through the indoor unit but since the fan isn't running, it isn't dumping conditioned air into the room. Every unit has a different way to disable the fan when it's not heating or cooling. My mini splits needed a jumper cut on the indoor control board but my air handler was configurable via a thermostat. This raises the issue of getting a proper temperature reading of the room. Without the air flowing over the thermistor in the indoor unit, the reported indoor temperature becomes wildly inaccurate. To get around this, a thermostat with a temperature sensor is needed. Mitsubishi has a few off the shelf options. I went with the popular route of adding a Bluetooth sensor to my ESPHome builds and I sell a bundle including the controller and remote temperature sensor. More information here: https://serin-labs.com/controller/room-sensors.html https://serin-labs.com/controller/room-sensors.html
- OxfordCommand 2mo agoi've installed 4 of your devices last week. they work flawlessly.
- robbiep 2mo agoThat’s incredible. I have an airtouch which I love but my parents have a Mitsubishi system that I’m fairly sure would be compatible, and a large floor space to manage. Apologies for the question, but for multi zone, you mention that the controller can pick up temperature. My understanding was that temperature is only captured at the intake, not in zones? (I’m familiar with airtouch where I have ?BTLE temperature sensors in the rooms/zones that are paired to my system). But how does this work with a Mitsubishi zoned system? Or am k over-reading the capabilities. (Or is it a similar deal, I just haven’t seen where to acquire these zone temp sensors from)
- akifbayram 2mo agoThanks! I just took a look at AirTouch. It seems they have a nice ecosystem. Their Mitsubishi Electric offerings [1] use the CN105 port (like the OP's device). I use the word zones on the Serin Multi Zone product page but it's interchangeable with indoor units. One indoor unit equals one zone. You can override the room (intake) temperature per indoor unit/zone using a controller plugged into the CN105 port (like the OP wrote about). Depending on the controller, it can pair with a Bluetooth sensor or listen to any other type of sensor from Home Assistant. By going the ESP32 path, you can use simple, off the shelf $10 BLE sensors. The Serin multi zone controller uses the centralized communication bus which isn't capable of overriding the indoor unit's room (intake) temperature. But if that is a must (which it is for ducted units), you can have both the multi-zone controller and a controller at every indoor unit without issue. So if you have an MHK2 thermostat on the wall and don't want to use their Kumo app anymore, the Serin multi zone controller will give you local control and you'll be able to retain the remote temperature sensor from the MHK2 thermostat. [1] https://theairstore.com.au/product/airtouch-gateway-mitsubishi-electric-kit/ https://theairstore.com.au/product/airtouch-gateway-mitsubis...
- robbiep 2mo agoI appreciate you taking the time to reply - that helps a lot. So essentially I get this and plug it into the CN105 port, and then everything will be in home assistant and I can get room/zone temperature control via BLE as well.
- globular-toast 2mo agoI'm hoping to get a mini-split system installed soon and thought I might as well look for something with HA integration. It's not easy. Some manufacturers like Samsung actually want to charge you monthly for cloud integration! Completely out of the question obviously. I came across this, and Mitsubishi is supposed to be good anyway. I would prefer something that's actually supported but I can't seem to find any other options. I could also very easily wire my units in so no need for WiFi. Maybe I can find a wired ethernet module.
- Gigachad 2mo agoMy ideal system would be something that does matter over thread with zero external internet access. Matter over thread devices are all standardized so no proprietary app required, and the newer iphones have a thread radio built in so you can control them without even a hub.
- XorNot 2mo agoWifi with a firewalled network is a lot easier to debug, which is how I do it in my house. There's no Internet from the IoT SSID.
- dobremeno 2mo agoI have my AC connected using Matter (over WiFi, not Thread) using esphome-matter, a relatively new extension to ESPHome + a small open PR [1] Since it's running ESPHome you can easily verify everything it's doing. Thread would be even better but this is good enough for me. 100x better than the original cloud app it came with. Still no proprietary app required, works on every platform. [1] https://github.com/DavidvtWout/esphome-matter/pull/53 https://github.com/DavidvtWout/esphome-matter/pull/53
- nemosaltat 2mo agoI used this guys thing https://clima.protoart.net/ https://clima.protoart.net/ after someone mentioned it in an HN comment last summer, then used claude to extend it this summer. A year in, I’m very pleased. Matter or thread would be nice, but these are super straightforward out of the box and totally local. The manufacturer documentation [0] for everything is great and it was perfect for my goal of getting them to show up in Savant as native thermostats [1] (likely beyond typical scope for split units). [0] https://protoart.net/knowledgebase/me_cn105_ata_wifi_http_api_mqtt_topics/ https://protoart.net/knowledgebase/me_cn105_ata_wifi_http_ap... [1] https://github.com/samstevenm/minisplit-local-public https://github.com/samstevenm/minisplit-local-public
- sippingabonedry 2mo agoFor anyone wondering why he would ever do this, it seems to be a type of hidden mini-split system used in euro-style shoebox flats, with a super-proprietary thermostat. Wi-Fi capability is an option at additional cost, but was not purchased. In the USA, wired thermostats tend to use standardized 24V wiring schemes, or 208V/240V for mains voltage heaters (electric heat, common on the west coast, especially in shitty apartments, central hot water/steam heating with 24V controls is more common on the east coast).
- Gigachad 2mo agoI had this same control panel in Australia. The actual AC unit was part of the strata common property and I think somehow shared between multiple units on the floor.
- HeavenFox 2mo agoFYI this kind of thermostat is actually better. American style thermostat put your HVAC system in either on or off state (basically PWM), whereas this kind of communicating thermostat can tell the system what the temperature is, so they adjust power accordingly. I do wish they have standardized protocol though.
- sippingabonedry 2mo agoDepends on your definition of better. It's a tradeoff I'm willing to make for simple, open I/O. It's not PWM but rather a "call" for heat, cooling, or fan. If I'm refinishing the wall I can (and have) put in a $3 thermostat in its place so I don't destroy the $300 one with paint and dust. It's also very easy to debug and repair, as I experienced on a day when the temperatures exceeded 100F and was able to execute an emergency repair myself. If companies like Nest and Ecobee were not allowed to exist, we would all be stuck with the overwhelmingly universally overpriced, proprietary garbage the OEMs put out.
- bob1029 2mo agoSingle stage hvac systems tend to have better performance in the max capacity cooling cases (Texas) and last significantly longer than units that rely on non-linear electronic devices. The difference can be as extreme as 10+ years of service life. There are residential systems that were installed in the 80s and 90s that are still running fine today. The hermetically sealed scroll compressor is an engineering marvel. The electronics will generally fail before any meaningful mechanical wear is incurred.
- llsf 2mo agoDoes anyone know if this could be used to "cap" the AC settings ? It could be useful in an airbnb place, where I want to limit the lowest (e.g. 18 degres Celsius) or hottest (e.g. 22 degres Celsius) the guest can set the AC.
- sippingabonedry 2mo agoIf you controlled the AC temperature remotely it's a great red flag to never rent that Airbnb. Some people like it cold when they sleep.
- llsf 2mo agoI understand, and I could make it clear in the description that AC is capped at 18 degres C minimum (65F), so people who like it very cold could skip my airbnb. Some AC can go ridiculously low (http://news.bbc.co.uk/2/hi/uk_news/england/3144803.stm http://news.bbc.co.uk/2/hi/uk_news/england/3144803.stm). I do not want to change the temperature remotely, I just want to not have the AC used to extremely cold temperature. I am fine to advertise it to weed of people who like it very cold.
- sippingabonedry 2mo agoI should have bothered to do the conversion... when I read your post I was immediately reminded of the recent laws in Italy that capped AC in public spaces to a minimum of 25C... 18C is awfully cold for a residence! Most programmable thermostats in the US do have built-in limits for device protection. I've never met anyone who sets AC in a home to lower than 68F and that is an absolute extreme. Most central AC systems are designed for ~20 degree temperature differential so on really hot days you'd have trouble getting it that low anyway unless the system is oversized.
- nottorp 2mo ago> 18C is awfully cold for a residence Yeah, why set the upper limit to 22 and not like 24-25? It will save you even more power for those that don't sit in your airbnb in a 3 piece business suit...
- nemosaltat 2mo agoI did a similar thing, heavily aided by Claude, after seeing the protart modules posted here on HN last year. https://github.com/samstevenm/minisplit-local-public https://github.com/samstevenm/minisplit-local-public Apologies for the Claudish, especially if anyone wades through the blog posts. I cringe when I reread them, but having some documentation on a working system is better than the ~none I was publishing before.
- userbinator 2mo agoMy idea of HVAC is that it should be "set and forget", so "smart" is the polar opposite of what I want. The round Honeywell on the wall has been doing its job for the past few decades, and will likely last many more with only an occasional cleaning.
- porknubbins 2mo agoIsn’t this is only true with central air though? Most other types of ac are not full climate solutions to leave running all the time and need some manual control. At least that’s how I use the mini split in my garage. I have to remember to give it 15-20 minutes headstart before I use the garage or will be really hot.
- sippingabonedry 2mo agoCheck out Uncle Pennybags over here with AC in his garage... All "smart" t-stats can be used in "dumb" mode but the remote control and monitoring is really the killer feature. Scheduling and presence is meh, if you're obsessed with energy savings I guess. I'd rather know if the system has failed when I'm 500 miles away before the pipes freeze.
- skolos 2mo agoIf you have same schedule every week, don't go on vacation, your kids don't have breaks, don't have seasons, then 'set and forget' dumb thermostat will work for you without any problems. For the rest of us we need some 'smartness' in our thermostats.
- userbinator 2mo agoYou shouldn't need to change the temperature regardless of those things. My house remains at 68-72F basically all the time. Thermal cycling accelerates aging of materials.
- spicypixel 2mo agoSounds expensive at the equivalent rate of 38 cents a kilowatt hour that I pay during the day.
- spicypixel 2mo agoAnyone tried this on the Bosch units? Their WiFi module comes as an addon too.
- pampas 2mo agoResearch it with an LLM. I've ordered all the stuff for Panasonic and Daikin after a deep planning session. It told me what connectors I need that Panasonic needs a level shifter. Both brands have open source libraries for the internal protocols and wiring. I wanted Zigbee so the ESP32 C6 was the way to go. The Panasonic units I have already have Wifi but most companies suck at this kind of thing. I couldn't get the Panasonic Wifi to pair with my router. Daikin also sell Wifi modules and people don't to like them.
- xx__yy 2mo agoCheck out: https://github.com/DomiStyle/esphome-panasonic-ac/blob/master/README.CZTACG1.md https://github.com/DomiStyle/esphome-panasonic-ac/blob/maste...
- madaxe_again 2mo agoI did similar with our coffee machine a year ago - I was bored of getting home from the school run to a cold pot of coffee because the machine automatically turns off the hot plate after 30 minutes, and it seems there is no such thing as a WiFi connected drip coffee machine. Kettles, yes, coffee machines, no. Dead simple. Cracked it open, chucked an ESP32 in there connected to the soft power button, and to the “machine is on” indicator on the display, which was conveniently on its own pin. No need for any thermal protection cleverness as the machine does that itself. Now I just turn it back on when I’m heading home, and no longer have to wait for the pot to warm up again. I then decided to stop using the “make coffee at time” functionality baked into the machine, as the kid gets up when the kid gets up, and the machine would either start early and wake her, or she’d get up before it and I’d have to go start it. Now, she opens her bedroom door, I get “kid is awake” alert on my phone, and the machine brews the coffee.
- dwedge 2mo ago> Now, she opens her bedroom door, I get “kid is awake” alert on my phone, and the machine brews the coffee. Out of all of the smart home threads and articles I've read over the years this is the only sentence that made me wish I had it. It's genius
- bluGill 2mo agoUntil the kid uses the bathroom in the middle of the night and goes back to bed. Though the GP seems to not mind stale coffee so perhaps he won't care. Exceptions like the above make automations hard.
- nicman23 2mo agomy solution is to capture the irs with flipper and replay them with tasmota
- looofooo0 2mo agohttps://github.com/heishamon/HeishaMon https://github.com/heishamon/HeishaMon
- gblargg 2mo agohttps://archive.is/KF0iH https://archive.is/KF0iH (no annoying popups)
- Minimaator 2mo ago[flagged]
- usagisushi 2mo agoMitsubishi AC units that support M-NET have a CN105 port. IIRC, my specific model uses a JST PA 5-pin connector rather than a JST PH 5-pin. As a small hack, I used the Python scripting interface in Home Assistant to replicate this [1] feature from Panasonic HVAC that gradually raises the cooling set point towards the morning. It is quite comfortable during the summer. [1]: http://getnavi.jp/appliances/681340/ http://getnavi.jp/appliances/681340/ (ja)
- a012 2mo agoThis is kinda unrelated but I learned while researching for my new AC that there are two Mitsubishi brands/companies, one is Mitsubishi Electric and the other is Mitsubishi Heavy Industrial. And their ACs are not the same, so just saying Mitsubishi AC probably could lead to problem. The one OP has is Mitsubishi Electric by the first photo.
- mrexroad 2mo agoTechnically, they’re both part of the Mitsubishi Group, the former zaibatsu; there are number of other Mitsubishi companies in this conglomerate as well. However, the Mitsubishi Pencil company is entirely unrelated to the Mitsubishi Group. Ironically, they share a very similar three diamond logo, which they registered and used years before Mitsubishi Group.
- TacticalCoder 2mo agoWhile reading this thread I noticed many have Mitsubishi HVAC while I'm the oddball with an Hitachi HVAC (which now belongs to Bosch [1]). [1] https://en.wikipedia.org/wiki/Johnson_Controls_Hitachi https://en.wikipedia.org/wiki/Johnson_Controls_Hitachi
- a012 2mo agoHa, I’m having the Hitachi as well
- launchkitcodes 2mo ago[dead]
- acyou 2mo agoThese mini split inverter units seem to be good for +/- 1 C, but the 2 C swing can feel quite substantial. PID control seems to be lacking overall, the control laws seem to be more basic. In particular, my unit waits until temperature deviation from setpoint exceeds 1C before cycling on. If I want finer control, there are a few options I can think of: 1. Spoof the temperature, add a TEC , heater, cooler or something to the sensor on the remote 2. Manipulate the controller buttons, change the setpoint down or up by 0.5 degrees so the unit kicks on after a 0.5 degree change instead of a 1 degree change 3. Spoof the temperature sensor itself, hack into the wiring with some transistor based circuit 4. Hack into the actual unit, fully take over the compressor and fan control 5. Buy a better unit or off the shelf controller 6. Spoof the remote control, reverse engineer the IR communication temperature signal This last option seems the least intrusive and cleanest, I see other people have done it, it's definitely a lot of work even with AI.
- xmddmx 2mo agoWould running the unit in Fahrenheit improve the sensitivity?
- acyou 2mo agoI don't think so? But I would have to do some testing to tell. The unit thermometer precision appears to be 0.2 C. I think the remote thermostat precision is worse than the thermostat on the unit itself.
- briHass 2mo agoIs your unit one of the ubiquitous Midea rebadges? Or at least one where the remote does 'follow me' type periodic, remote temp reporting? If so, you're right, the easiest way is to build/buy an IR blaster module for a microcontroller (ESP32 if you want wifi) and connect a temperature sensor. HA/EspHome is overkill for this, but can be useful for the large catalog of pre built integrations. Most of them are built using/on IR libraries for 'Arduino' anyway, so you can easily roll your own with a half dozen lines of C++. Mapping out your own PID correction algorithm (esp says the room is 72 F when it's really 70 F to get it to cool sooner), but usually just having the remote room temp sensor near where you'd be sitting instead of near the ceiling or in the return air stream gets you close enough.
- hattmall 2mo agoIf anyone is looking for something similar it's worth looking into A somewhat less complex solution that preserves all functionality. Use the IR receiver plus a broadlink IR Hub. You can meet all the goals here, run it all locally the only downside is no 2 way communication. So if you do change the thermostat via the wall it won't be reflected in your app.
- BrandoElFollito 2mo agoYou can add a camera pointing to the display and analyze the image. You would have a perfect galvanic separation for reasons.
- seniorsassycat 2mo agoThis project isn't very complicated, doesn't require extra power source, and doesn't beep every time you change the settings.
- monitron 2mo ago[dead]
- webinar 2mo agoI've been using mitsubishi2MQTT with Home Assistant. It's been working great for several years. https://github.com/gysmo38/mitsubishi2MQTT https://github.com/gysmo38/mitsubishi2MQTT
- scosman 2mo agoI've done this exact mode on my Mitsubishi ACs. Despite being old units that came with the house, they are instantly responsive and report back current temperature flawlessly. ESPHome device are consistently faster and more reliable than any smart home tech I buy at 10x the price (not hard with $3 boards).
- xx__yy 2mo agoFor those of us with Panasonic systems, see: https://github.com/DomiStyle/esphome-panasonic-ac/blob/master/README.CZTACG1.md https://github.com/DomiStyle/esphome-panasonic-ac/blob/maste... https://github.com/DomiStyle/esphome-panasonic-ac/issues/63 https://github.com/DomiStyle/esphome-panasonic-ac/issues/63
- noja 2mo agoThis seems to be better featured than ir blasters like Tado Smart AC Control (which is not bidirectional)