5 ms·
I got a Zigbee power breaker and hooked it up so all my flat's power goes through it, and then made an e-ink display to show my power consumption: https://www.
by stavros 3y ago
I got a Zigbee power breaker and hooked it up so all my flat's power goes through it, and then made an e-ink display to show my power consumption:
https://www.stavros.io/posts/making-the-timeframe/ https://www.stavros.io/posts/making-the-timeframe/
- shrx 3y agoI'm curious, which power breaker do you have?
- stavros 3y agoThis one: https://www.aliexpress.com/item/1005005657383634.html?spm=a2g0n.order_detail.order_detail_item.3.29d9f19cVGy4lV https://www.aliexpress.com/item/1005005657383634.html?spm=a2...
- wannacboatmovie 3y agoYou're running all your flat's power through that $14 Chinese rubbish and never assumed that shortcuts were taken or quality would be an issue? How do you know it will continue to function as a circuit breaker and isn't just a piece of wire inside? For the uninitiated, CE marking is meaningless (it allows for self-certification). I'd like to see Big Clive do a teardown of one of those.
- theshrike79 3y agoYou can get less shit ones that aren't made of Chinesium from Shelly
- wannacboatmovie 3y agoGreat suggestion. Some of their modules appear to be UL certified.
- baq 3y agoYeah you need to shop for these specifically. They come at a premium.
- theshrike79 3y agoSome of them (most of the latest models) are scriptable on-device. There are some ready-made scripts for the Nordics that check the current electricity prices and use those with some basic rulesets to see if the electric heating in a house should be on or off for example. I just use mine to turn off the ice machine at 22:00 so it doesn't run through the night :D
- stavros 3y ago> How do you know it will continue to function as a circuit breaker and isn't just a piece of wire inside? I don't care. I connected my previous breaker after it.
- wannacboatmovie 3y agoWhy not just use a current transformer? (Clamp over wire type) It's much safer.
- stavros 3y agoDo you know of a Zigbee one? That's also a good option.
- wannacboatmovie 3y agoSome options at the $10 price point on AliExpress, though I cannot recommend one, maybe another reader can. CTs are the generally accepted way to do this and don't have to modify mains wiring. Could also build your own; CTs are inexpensive.
- stevenhuang 3y ago> Why not just Please learn to never use this type of phrasing when offering suggestions. Your entire exchange was needlessly patronizing and off-putting.
- wannacboatmovie 3y agoThanks Dad.
- hurflmurfl 3y agoA bit funny, but I personally found "please learn to never..." to be MUCH more off-putting and patronizing than the "why not just...". Maybe just something about the latter being interpreted as a question, and the former being interpreted as an order.
- dist-epoch 3y ago> $14 Chinese rubbish Where do you think the "quality" devices are made?
- londons_explore 3y agoThere are 2 ways to design these. They could use a regular relay, or they could use a solid state relay. Solid state relays have widespread fraud. Like 60% of the ones on amazon will catch fire or fail before they hit the rated current. Trade suppliers generally don't sell them at >30 amps. Regular relays up to 10 amps are cheap and reliable. Beyond that, they get expensive surprisingly fast, and the reliability is hit or miss. They fail in numerous ways, but the most concerning one is the plastic case melting and catching fire. The chance of failure depends on the nature of the load (capacitive or inductive loads will dramatically shorten a relays lifespan). In my professional career, I have witnessed ~20 of the above devices failing, with melted bits or burn marks, but of that sample none has burned down a building, yet. But I'd say that was more down to luck than good design. In general, I would trust a china-device for monitoring power, but not for switching anything more than ~10 amps (1 outlet).
- baq 3y agoIs it the switching that kills the relay or is it enough to start/stop the load? E.g. if I have a 10A smart plug monitoring power on a small waist-tall freezer in the garage will it eventually damage the switching function?
- londons_explore 3y agoIts generally the switching, although I wouldn't professionally sign off an undersized relay on the basis of 'it never switches, so its fine'. The switching under load causes the contacts to get worn, then the large load causes the now-worn contacts to get hot, and the plastic supports melt and catch fire.
- squarefoot 3y agoA mains connected circuit designed to minimum costs could have all sorts of corner cuts: bad capacitors, no overvoltage protection, no back EMF from load protection, bad isolation to the driving circuit, etc, so that it could work flawlessly for decades, but also stop working after a while because of a spark that welded the contacts together, or mains voltage to enter the driving circuit because of moisture and insufficient creepage between high and low voltage tracks, etc. I use a lot of cheap Chinese products in non critical contexts, but I'd avoid them with mains voltage or in any safety critical use.
- whatble 3y agoThis is NOT a valid 63 Amps rated breaker, or 63 Amp anything for that matter. The screw terminal will melt. Based on the screw terminal, without looking inside, I would rate it not higher than 10 Amps. Don't pass your whole apartment through it.
- RedShift1 3y agoI have seen 63 A (and higher rated) equipment, this is not it. This is a fire hazard.
- deleted 3y ago[deleted]
- 3abiton 3y agoThat was a great write up! I wish I had the time to follow-up this guide. Thanks for sharing it!
- stavros 3y agoThank you! It's not very hard to use, you basically just flash my firmware and use my script to display images on the Timeframe. That's about it.
- hackernewds 3y agoRelated to your comment so much, I got hurt
- gog 3y agoCan you link the power breaker?
- stavros 3y agoThis one: https://www.aliexpress.com/item/1005005657383634.html?spm=a2g0n.order_detail.order_detail_item.3.29d9f19cVGy4lV https://www.aliexpress.com/item/1005005657383634.html?spm=a2...
- homero 3y agoIt's crazy to run any power through that. Only safe option are current transformers
- sifttio 3y agoDo you have any you would recommend? I'll love you for a link, and like you for a brand name. Not being a dick here, I'm genuinely looking for one that I don't have to lose sleep over installing.
- homero 3y agoWould this work? https://github.com/magico13/ha-emporia-vue https://github.com/magico13/ha-emporia-vue You can do mains only or every circuit https://shop.emporiaenergy.com/collections/in-panel-energy-monitors https://shop.emporiaenergy.com/collections/in-panel-energy-m...
- aksss 3y agoI think the aliexpress link for the display is busted (as they do). A natural integration would be with Home Assistant. I’m not sure if the Earu breaker has an OOTB integration with HA yet, beyond doing something like Zigbee2MQTT and configuring entities for readings. It’s a good pattern though - integrate meter with your automation hub, let the automation hub push the images to displays, for meter and everything else.
- microtonal 3y agoFor people in The Netherlands: all Smart Meters that the net maintainers installed (are required to) support the P1 standard, which provides a standardized interface for customers to read out current current draw, cumulative power use, etc. Usually gas is hooked as well. You can hook up a cheap dongle to expose the stats in an app. For instance, we use: https://www.homewizard.com/nl/shop/wi-fi-p1-meter/ https://www.homewizard.com/nl/shop/wi-fi-p1-meter/ This meter also exposes an API on the local network. I have written a small driver for the SmartThings Hub, so that you can get the stats/graphs in the SmartThings app as well (we use a SmartThings hub for Zigbee/Z-Wave devices): https://github.com/danieldk/homewizard-energy https://github.com/danieldk/homewizard-energy
- Maakuth 3y agoThis applies to Finland and Sweden too, perhaps others to follow.
- benhurmarcel 3y agoSame in France, the official meters have an interface on which you can plug a Raspberry Pi for example to read the data live.
- swiftcoder 3y agoDo you know of an equivalent for the optical ports that speak DLMS/COSEM? The P1 standard doesn't seem to have caught on here in Spain just yet.
- yard2010 3y ago
- sifttio 3y agoThis guy is funny, I like him. I just bought a $12 annual sub to his project IMGZ. I'm not affiliated at all, if you're thinking this is an elaborate ad. https://imgz.org/ https://imgz.org/ Hey dude, fix your "open in wallet" button when paying with BTC. The link is janked up. Otherwise, it works great. See https://imgz.org/iAB4tgaJ/ https://imgz.org/iAB4tgaJ/