I've hired enough licensed, bonded, certified, well-recommended, well-reviewed professionals who completely botched the jobs* to agree wholeheartedly with your
by sowbug 3y ago
I've hired enough licensed, bonded, certified, well-recommended, well-reviewed professionals who completely botched the jobs* to agree wholeheartedly with your sentiment. You can't hire someone without thoroughly understanding what they're doing, and once you reach that level of understanding, you absolutely can make an intelligent decision whether to buy or build. At the point where my house burns down, I really don't care about the credentials of the person who made the mistake. Rather, I personally make sure my house doesn't burn down.
* Solar panels installed facing North in the Northern Hemisphere; rapid-shutdown switch installed inside a home; supply side of 240v connection to backyard office has male prongs; fence built with non-pressure-treated wood contacting the soil. The list goes on, and these are only the errors I've discovered in 20+ years of being a homeowner.
- jacquesm 3y agoIf only it was just the tradespeople. I've had an electrical inspector argue that I should route the ground from my windmilltower into the house and bond it to the distribution panel rather than to ground the windmilltower at the base of the tower. So in case of lightning strike (which is pretty much a given) that would invite that lightning into your home right at the distribution panel. People may be following 'the code' but that doesn't mean they actually understand what they are doing. He wouldn't take responsibility for it, I asked him to put it in writing as an instruction and sign off on it so I could pass it to my insurance company. That never happened...
- amluto 3y agoI don’t know the whole setup, but the inspector is likely right. When you have a feeder to an outbuilding (or external structure or piece of equipment or subpanel or basically anything else), you supply it with the intentionally current-carrying wires and the ground. (Ground may be called “equipment grounding conductor” or “protective earth” or perhaps something else in your jurisdiction. It’s a wire or the metallic conduit you used.) And this is important for lots of reasons. If there is a fault from a hot wire to a grounded object, this (if done correctly) allows the upstream overcurrent protection to trip. And it minimizes the voltage rise of the object that gets energized. And it keeps the line-to-ground voltage within spec. And using a separate ground means that the voltage of “ground” doesn’t get pulled up by resistance in the neutral wire and that current doesn’t normally flow through “ground”. You should, of course, also connect the ground wire to Earth, well, at the base of the structure. And possibly also install something to help conduct lightning currents from the non-ground conductors to ground in the event of a lightning strike.
- jacquesm 3y ago> I don’t know the whole setup, but the inspector is likely right. That's an interesting start to your comment. So you don't know the whole setup but you do know the inspector is likely right. Well: if he was likely right he would have not shied away from putting it in writing. What happened was that halfway into the conversation he realized he was wrong, hightailed it out of there and simply didn't want to admit that he was wrong. I do know the whole setup. And I have spent enough time installing high stuff made out of metal (mostly: antenna masts) to know that the last thing you want is to give lightning a short path into your dwelling. His whole experience seemed to be based on simple domestic installations, and instead of just admitting that he didn't know exactly what to do and to go look it up or ask someone more experienced to look it over he dug in. Human nature, I get it, but this is safety we're talking about and the amount of flak the OP is getting in this thread from people that likely have more experience with keyboards than with real world engineering is telling. Just like you: they don't know the whole setup but they'll argue that it is unsafe, will void your insurance, will get you investigated for arson(!) and might kill your kids. You last paragraph is exactly the problem: he outright forbade me to ground at the base of the tower because that was in his opinion unsafe. But it wasn't his life and property that was at stake. I've seen up close what lightning will do to various pieces of gear, it isn't pretty, to put it mildly and you make sure you keep it as far away from your house as you can. And have spark gaps to ground at the point of entry for your power cable, just in case. Finally: the proof of the pudding is in the eating. When after a year we pulled the tower down again there was evidence of multiple strikes on the nacelle body at the top of the tower, all of which were dealt with gracefully, to the point that we didn't even realize the machine had been hit. What helped is that for the whole installation we had a massive amount of help from an experienced wind turbine vendor who took an interest in our project.
- marcosdumay 3y ago> you supply it with the intentionally current-carrying wires and the ground Whether you connect both grounds to both themselves and Earth, or just connect both grounds to Earth, or connect them to Earth once and connect them both depends on so many details, it's not funny. What is certain is that you don't want something that doubles as a lightning rod protected on the same internal circuit as your house. So your rationale doesn't apply to the GP. But anyway, every time somebody talks about electrical installations on the internet, somebody says some version of "If there is a fault from a hot wire to a grounded object, this (if done correctly) allows the upstream overcurrent protection to trip." Is it still a recommended practice on the US to rely on overcurrent protection to protect against current leakage? It's an horrible practice, as it requires several amperes of leakage before triggering.