>edit: Gah! you don't even have to do that just flip the flipping wires) Isn't that essentially what all ethernet cables do? it's not like this something never
by dylan604 3y ago
>edit: Gah! you don't even have to do that just flip the flipping wires)
Isn't that essentially what all ethernet cables do? it's not like this something never done before.
- JoblessWonder 3y agoWhen was Auto MDI-X introduced? A quick google failed to get me an answer but I remember USB being available while I still needed a crossover cable to hook up 2 switches.
- Scoundreller 3y agooh god, I was made to be an idiot when I once told someone they would need a crossover cable to do what they wanted to do a few years ago...
- JoblessWonder 3y agoIf it makes you feel any better... for some reason there are some currently in production business jets that still require crossover cables for maintenance... so they ARE still required sometimes.
- Scoundreller 3y agoI've also dug further into my parts bin thinking "oh, that yellow cable would've been perfect, but I need a non-crossover cable"... could've used the yellow one instead of digging further. Ah well.
- DANmode 3y agoSecurity through obscurity?
- mmac_ 3y agoYou encounter this in older industrial equipment. Some of the old ethernet chipsets don't support automatically switching the pairs around. It's not really a problem since at least in our local area they need to be installed by licensed cablers who are used to dealing with legacy devices. Many devices won't get updated until chipsets go EOL or there's some other compelling reason to do so. Having said that, modern chipsets seem to all support it.
- rasz 3y agoTogether with 1Gbit ratification, so ~2000
- londons_explore 3y agoEthernet hardware now has auto-crossover. However, that hasn't always been the case. There was a good decade in the 90's where you needed a special cable wiring if you wanted to connect two computers vs a computer to a switch.
- hedora 3y agoHah! I recently had to put ends on a Cat 6 cable for weird reasons, and spent a few minutes deciding if it needed to be crossover or not.
- distract8901 3y agoThe worst is trying to repair one end of an existing cable and having to think really hard about whether to use A or B wiring.
- dylan604 3y agosometimes, it's easier to replace both ends. or replace the same end, twice
- WesleyJohnson 3y agoRandom anecdote: I worked at a company with an on-prem server room and the building got struck by lightning. It fried some servers and quite a few nic cards on employee computers. Our CTO decided since we'd be in the building doing hardware replacements anyway, now was the time to redo our wiring closest as well. That was my introduction to wiring up CAT-5 cables and rj45 connectors and, with so many to make, I needed a way to remember the wiring diagram without having to read it over and over or use a visual reference. The mnemonic rhythm I used to remember the pattern was "orange/white, orange... green/white, blue... blue/white, green... brown/white, brown". Of course, said out loud, you couldn't tell if it was "orange/white, orange" or "orange, white/orange" and I kept confusing the rest of the team when I'd say it, but it worked for me. This was circa 2005/2006 and I still say it like that. It just stuck.