People seem to have forgotten the boom of prefab/modular houses in the 1960s/1970s. It turns out after the cost of delivery and final assembly on location you l
by vel0city 3y ago
People seem to have forgotten the boom of prefab/modular houses in the 1960s/1970s. It turns out after the cost of delivery and final assembly on location you lose out a good chunk of the efficiency of the factory line production.
The biggest innovations to construction are probably to be had in better/faster/easier plumbing and electrical connections, making it faster and more reliable to install all the fixtures. Being able to plumb and install a whole bathroom in a couple of hours instead of most of a day while reducing the odds of needing rework would be a decent boost. We've seen some improvement in this already though with things like PEX and Wago, I imagine even more modular designs can improve this even more. The challenge with this is actually getting adoption and approval for some of this stuff.
- jacquesm 3y agoWago is a mixed blessing.
- jjoonathan 3y agoWago is better than sliced bread, the only people upset with them are just butthurt that their knowledge of how to use a wire nut is no longer a competitive moat.
- jacquesm 3y agoWhat a silly response. No, Wago has in some cases higher contact resistance than other means of splicing hard copper wire. And in those cases it can lead to an increase in temperature, arcing and possibly fire. It is much more convenient and I highly doubt anybody that can splice a couple of wires sees that ability as a means to keep the competition out. But there are drawbacks and you should be aware of them. When doing high current and tri-phase connections I will use a wire nut, otherwise I use a Wago.
- aidenn0 3y agoJust because you seem to have a lot of experience, any thoughts on the old-style grey Wago vs the new-style clear ones?
- jacquesm 3y agoNew ones for sure. Those stab-ins come loose much easier and are harder to get right. There are some stab-ins that are transparent, those at least allow you to inspect that the wire is seated properly. But be careful when you manipulate them to close a junction box because any twisting of the wire can cause them to slip loose.
- aidenn0 3y agoOh, I meant the gray 222s vs the clear 221s. The whole "I can see it right" thing is nice with the 221s, but I've had people tell me that the 221s don't hold as well as the 222s.
- jacquesm 3y agoI couldn't tell you without bench testing them and that - done right, not just for youtube views and clicks - is a whole pile of work.
- btbuilder 3y agoCould you elaborate? All connectors regardless of type have current rating and specify what wire gauges they are compatible with. It seems like it would be a big deal if a properly installed Wago could catch fire. I know that wire nuts can sometimes have a better failure rate when tested at much higher currents than either connector is rated for but this is equivalent of ingredients causing disease when you consume 1000 times more than is typical.
- mindslight 3y agoCode and device approval are basically minimum standards. For example it's common wisdom to avoid "backstab" connections on receptacles, yet (at least one) NRTL keeps their approval, and they keep selling them. Go image search for "receptacle backstab" and see all the melted ones. Or look at how romex/NM (doesn't) hold up to mild rodent activity. I'm not saying that Wagos are in the same category as receptacle backstabs. The point is there are definitely quality/safety reasons to choose one approved method over another.
- organsnyder 3y ago> Or look at how romex/NM (doesn't) hold up to mild rodent activity. We had a mouse chew the romex going to the receptacle for our dishwasher (as well as the drain line). He must’ve gotten quite the shock, since the breaker tripped. The wire was charred and had exposed copper.
- jacquesm 3y agoWago use a spring loaded contact to touch the wire and there are at least two of these in series for every connection. This works quite well for currents up to about 20 A, and if the Wago is applied properly: straight wire, right thickness and proper length stripped. Obviously if you mess any of those up all bets are off. But assuming proper installation that 20A is still a potential issue: lots of gear has a multiple of that for a short time when starting up. That's when contact resistance starts to become important, and as connections age mechanical resilience comes into play and what was borderline before may become a problem. Contact resistance is ideally constant but as connections age they are pretty much a factor of how much copper is in contact with each other and this is where wire nuts do a better job. So a brand new Wago splice and a wire nut splice will probably have approximately the same contact resistance, but several years down the line it may well be quite different. Motors and other large inductive loads are especially nasty in this respect, which is why there are several 'curves' in use for ground fault interruptors. The most common, the B curve will do a max or 3 to 5x for a short period of time before it kicks in, but a C or D curve can go much, much higher. And then that contact resistance (which wasn't such a huge problem so far) suddenly is a problem. Now you're generating serious Wattage in a small space that has no good way to get rid of the heat. Imagine an elevator motor or a shop lift or or something like that. This sort of application is where I would never use a Wago. But for regular low power stuff in my house I use them all the time, lights, bedroom outlets and so on. But my 17 KW Solar inverter is using crimped on joints and I checked the torque on the screws in the plug to make sure it's all up to spec. Those are not things to mess around with and hope it will hold. If you want to have some fun take a FLIR across an older exposed installation, it will definitely help to visualize what contact resistance will do.
- gjsman-1000 3y ago> And in those cases it can lead to an increase in temperature, arcing and possibly fire. Prove that. There is no evidence for that if they are used within spec - and if there was, UL and CSA would immediately pull their listings. There is however, plenty of FUD on the internet about Wagos being dangerous, even though plenty of tests have shown this is not true. For example, this test which showed a five-connector Wago running at maximum of rated limit releases about 1W of heat. A little warm, nothing dangerous. https://www.youtube.com/watch?v=zgjo36-jaFY https://www.youtube.com/watch?v=zgjo36-jaFY https://www.youtube.com/watch?v=OhFwcEcNF2I https://www.youtube.com/watch?v=OhFwcEcNF2I Also, you should look into how common electrical fires are in Germany if you really want to prove your case. Wago popularity over there is insane. Wire nuts are viewed as archaic and most homeowners don't even know they exist.
- jacquesm 3y agoWago's fail all the time, as do wire nuts. Both need to be applied properly. Applying a Wago properly is easier than applying a wire nut properly. But Wago's really do have higher contact resistance (especially when they age), can have higher temps and I've personally seen more than one case of a molten Wago, including one where the whole metal part had molten its way out of the container, as well as one where the tabs had gone missing and were all locked in the 'open' position (no idea how that came to be). I do a lot of house renovations, have installed a whole pile of solar gear (including some pretty heavy duty inverters), and have installed a complete machine shop. You're more than welcome to question all of that but I'm not in your pay and I don't need to prove anything, my personal experience is good enough for a forum comment. I use both, for where I think they are most appropriate and that's how I treat all tech: apply it for its strengths and be aware of the weaknesses.
- jjoonathan 3y agoWire nuts are easy to fuck up. Wagos are hard to fuck up. That's why wire nuts cause fires and wagos don't. If I had a dollar for every wire nut I've ever fished out of the bottom of an electrical box, I'd be able to buy a nice dinner for the whole family, whereas I'd leave the dollar store empty handed if someone had forced those numptys to use wagos.
- jacquesm 3y ago> Wire nuts are easy to fuck up. > Wagos are hard to fuck up. This we readily agree on, but I've seen both being fucked up enough to go over the electrical system with a FLIR for any new property purchase. The stuff you find like that you won't believe, including dead rodents, completely burned out junction boxes, arcing so strong that you could smell the ozone meters away from the junction box (essentially a matter of time), wire stripped bare over ridiculously long distances and so on. Other code violations such as using only black 1.5 mm^2 for a whole installation and non in-ground approved cable buried a couple of inches under a driveway. My advice is to use both, each for their strengths. If you're wiring up an electric motor of any sizeable power I'd definitely do that using the best connection possible, so a crimped on screw terminal if that's a possibility, a wire nut if it isn't and a Wago if there isn't anything else. But I'd check the drop across the Wago before calling it a day, just in case. Start-up currents are pretty nasty. Also: anything behind a type C or D breaker.
- bbradley406 3y ago> Wire nuts are easy to fuck up Can't agree on this at all. You twist the wires together in the direction the nut threads on, then screw it on. After it's done give each leg a light pull to make sure it's secure. Where and how are people fucking this up? I could see using the wrong size, leaving stripped wire outside the nut or stuffing way too many wires into one nut, but other than that I'm baffled.
- jacquesm 3y agoHere are some of the ways in which I've seen people mess this up: - too small a diameter wire to properly engage the thread - uneven insulation so only the tops get joined - not enough twist so only the first couple of threads engage - stranded wire cut through completely by the threads - wrong kind of wire (aluminum! which really needs its particular kind of connectors and is fortunately phased out but you may come across it in older installations). - too many wires for the size nut (usually 5 is the max, depending on thickness) - re-using oxidized wire ends because there isn't enough wire length - wires not twisted at all before applying the nut - leaving out the wire nut spring (!) (presumably to make room for more wires...) - spring upside down - untwisting the nut and the spring, then untwisting the wires to add another splice - bending the copper too often (metal fatigue) - not inspected after twisting it on - too much insulation stripped - wire end damaged during insulation stripping - wires twisted in the wrong direction And so on... In comparison some of these will apply to Wagos but in general they have fewer ways of doing things wrong and adding another splice is much easier with a Wago. DIY electrical is great, it saves a ton of money. But the kind of stuff you come across can make your hair stand on end. The house I live in came with an electrical installation that was downright dangerous, I live here for 5 years now and I think I've fixed most of it but every now and then a new surprise pops up. Recently: a wall socket stucco'd over but before they stucco'd it over a piece of flex wire (twin strand) was connected through a groove cut into the wall to a brand new in-wall grounded socket of which the ground was left unconnected. Whoever made that (I suspect the previous occupant) is a complete idiot when it comes to electricity.
- irrational 3y agoIn what way? I recently switched to using Wago and they are so much better than wire nuts that I can’t see any downsides (other than cost).
- rootusrootus 3y agoI could believe that wire nuts for regular size wires (say, 12 awg) have a pretty good reliability record -- only after they've been twisted together by an experienced electrician and then capped, there is great wire contact and physical strength. I've occasionally had a wire slip from a Wago when I do a test pull. But I'm with you, I'm happy with Wago. When I'm doing the work myself, that's what I use. Though I do use wire nuts for my big wire connections (6 awg). They probably don't even have lever nuts for that size, but I didn't look.
- jacquesm 3y agoAt least you do a test pull. You're ahead of 99% right there! Good for you.
- aidenn0 3y agoUnless you're using stranded wire. It's definitely possible to use a wire-nut correctly with stranded wire, but it's much, much harder. Also (in the US at least) stranded is almost always lighting so the slightly increased contact-resistance is a non-issue.
- jacquesm 3y agoThat's true, for stranded wire wire nuts are less than ideal because the thread tends to severe the strands if you're not super careful. If you do use them always twine the threads and if you can use a crimp on sleeve of the right diameter.
- mavhc 3y agoI want at a minimum the wires in my walls/floors to be easy to edit, inside trunking in the wall/trapdoors in the floorboards. Why would you have to cut holes in your wall, edit the cables inside, and then plaster over them again to cause the same problem next time? Madness
- rcme 3y agoWhy would you want to look at access panels every day for a once-in-a-decade issue? Patching a hole in a wall is really easy, all things considered.
- dgacmu 3y agoI'd be curious to see examples of very tastefully concealed / unobtrusive / or well integrated access panels. (Asking for myself, because I agree with both of you - I hate having to open my lathe and plaster walls, but I also don't relish the idea of blatant access panels). Maybe 8"x8" panels with electrical receptacles and data ports integrated so they're also functional...
- rcme 3y agoYou could leave lathe off of the tops and bottoms of your walls and cover those sections with baseboards and crown molding. Then you pop off the baseboards / crown molding to get access behind the wall.
- photonerd 3y agoI’ve done a smaller version of this with painted electrical junction box covers. Basically have a cable run behind there and one of these every so often (especially at junctions). Usually for networking or audio/video but I’ve run power cables like that too.
- mikeyouse 3y agoSome of the new Aria / Aria-like ones are pretty nice looking; https://ariavent.com/products/flush-access-panel-luxe https://ariavent.com/products/flush-access-panel-luxe Quick video showing it in 'action': https://www.youtube.com/shorts/nVo2pxSHCR0 https://www.youtube.com/shorts/nVo2pxSHCR0
- paiute 3y agoHaving just finished a build, this is very true. New construction methods are amazing. My home had rough in plumbing in a day. Scheduling, inspections, and credentials eat up the most time. Why a plumber can't hook up power to a water heater is beyond me. That alone ate a week.
- deleted 3y ago[deleted]
- wredue 3y agoWhat? This is odd given that in a lot of places, a home owner can run their whole electrical, and the inspection is just a dude plugging shit in to the receptacles. Also, are most modern water heaters not just a standard plug in? Even my dishwasher, which was a curiously long hold out, doesn’t have direct power any more. Around here, home owners are not allowed to plumb, not even with inspection. Plumbing permits are only given to plumbers.
- kjs3 3y agoMy brand new (last year, anyway) high efficiency water heater is direct wired. The plumbers connected it. I can't say I've ever seen a plug-in water heater (bigger than a few gallons).
- SoftTalker 3y agoI think you certainly could set up a water heater with something like a clothes dryer lead and plug, but I've never seen it done. I'm not sure why kitchen ranges and clothes dryers tend to be plug-in and water heaters tend to be hard-wired; in my experience they all get replaced about every 10 years or so.
- ruduhudi 3y agoIsn‘t that mostly a question of the wattage the appliance needs? Here in Germany we have a Max of 3000W on the regular plugs which is why, for example, stoves need special plugs. Not sure about water heaters though
- acuozzo 3y ago> People seem to have forgotten the boom of prefab/modular houses in the 1960s/1970s Don't forget the even earlier: https://en.wikipedia.org/wiki/Lustron_house https://en.wikipedia.org/wiki/Lustron_house
- utopcell 3y agoAnd Sears homes: https://en.m.wikipedia.org/wiki/Sears_Modern_Homes https://en.m.wikipedia.org/wiki/Sears_Modern_Homes
- nemo44x 3y agoThere was still a lot of work needed to be done with those. A foundation had to be built to spec and a chimney built. Plumbing and electrical work was needed after the rough-in and then of course all the finishing work. What you were buying was a design and the materials. Saying that, in the early 20th century there wasn't too much to the electrical and the house probably had basic plumbing for a single bathroom and a kitchen sink plus radiators and a boiler that was probably onsite oil fed. A modern home has far more to consider including insulation, far more electrical and plumbing, HVAC, etc.
- madaxe_again 3y agoEven with modern plumbing, wiring, tiling substrates, etc., bathrooms are an utter pain in the arse. You’ve got utilities going all over the place, multiple drainage points, tiling, underfloor heating, studs to position so things like shelves, heated towel rails and all the rest end up where you want them, ventilation, and on it goes - and all of it has to happen sequentially, often a bit of this, then a bit of that, and then back to the first thing again. Having done several bathrooms, top to tail, I would gladly just buy one off the shelf if it were good. I think there’s a massive opportunity in modular bathrooms. I’ve seen them done amazingly badly (think: the plastic cube badly perched in a corner of your Victorian seaside hotel, in which you have to crouch under the shower, while it hoses down the toilet paper), I’ve seen them done so well you wouldn’t have a clue you were in a room delivered in a box. The latter, I’ve only seen in Latvia, by a Latvian company - but I think the concept has legs.
- rtpg 3y agoJapan has modular bathrooms, it’s pretty nice (though it does mean that almost every bathroom looks like one of 3 kinds of bathrooms). Even the basic ones are more functional than what I see in 90% of US bathrooms, but it is just huge chunks of plastic and cleaning is a whole thing.
- irrational 3y agoHow do they replace it when it is inevitably damaged or worn out?
- artsytrashcan 3y agoTear the entire thing out and replace it. You have to understand that housing (separate from land) isn't so speculative in Japan, however; a "worn out" bathroom is likely in a house that's going to be torn down completely and replaced.
- rtpg 3y agoThe “houses getting torn down all the time” practice is getting less and less true. It’s becoming fairly common to just do a bunch of renovations since the old houses now are also from the modern mass production era (whereas in the past your old house was likely to be a much bigger pain in butt to improve). Though I do not believe that we have entered a full speculative era from this.
- blamazon 3y ago> PEX and Wago I'd also add Viega to the list, it is well accepted in many places and makes copper soldering unnecessary to join copper pipes in many applications by instead using a crimped fitting that only takes a few seconds to crimp with a power tool, it's a game changer for plumbers working with copper and even carbon steel pipes up to 4 inches in diameter. https://www.viega.us/en/homepage.html https://www.viega.us/en/homepage.html
- xnx 3y agoSharkBite connectors don't even require a tool.
- hahamrfunnyguy 3y agoI do a lot of my own plumbing but I had a larger job I didn't want to do. I had assumed the plumber was going to use copper and sweat connections. He basically told me that copper was way up and the labor costs of the sweat connections would make it more expensive. I had him go with PEX and sharkbite connectors. In retrospect, doing the job myself that way wouldn't have been too bad. The sharkbite connectors seem pretty reliable. I used some when I first bought this place and they've been installed for about 20 years now. I still prefer the traditional sweat joints, but maybe it's just not worth the investment of time?
- kokanee 3y agoI had a similar situation, but I had him go with PEX and sweat connections. I suppose I would have considered it for a connection in my garage, but this was deep in my crawl space in an area where you only visit if you absolutely have to. Not a place to mess around with products that have half the life expectancy of the tried-and-true methods. I wonder if any builders are using this approach - solder in the crawl space and behind drywall, but shark bite in accessible areas.
- voisin 3y ago> The biggest innovations to construction are probably to be had in better/faster/easier plumbing and electrical connections, making it faster and more reliable to install all the fixtures I think maybe 90% of the benefit could be had by simply having good, efficient design in the first place with the same traditional connections. It is unbelievable how much quicker it is to build when all the plumbing is stacked within a small footprint, rather than running all over the place.
- ilyt 3y agoIf you try to save on workforce cost by.... making materials more expensive, that only works if materials are not the big part of the cost. But they are for housing, usually by far the biggest cost. If it is just "mold plastic differently so it can be put together quickly" and doesn't add much cost, it is worth it, but if you prefab walls cost more than raw materials + labour to build something similar... and on top of that are less elastic (just certain width and height etc.).