3 ms·
My 2 cents: Find your local "design heating temperature" and then determine your tolerance for the house falling a few degrees below the setpoint during the 1%
by sokoloff 4y ago
My 2 cents: Find your local "design heating temperature" and then determine your tolerance for the house falling a few degrees below the setpoint during the 1% of hours that the outside temperature will be below that. Most people would be fine if their house fell to 67°F or 68°F for a few hours, especially since some of those hours are bound to be at night (where other people are setting their stats back to those levels anyway and you might well be asleep and never notice).
If you have no other gas appliances and generally reliable electric supply, I'd be inclined towards going with electric backup. That avoids the $10-15/month gas meter charge, which pays for a fair amount of the more costly electric heat. If you have other gas appliances and cheap [at least for now] natural gas supply, going with a natural gas backup allows you to use the cheaper source of heat for both backup and/or in case electricity rates go up substantially versus gas.
CO risk is minimal and you should have a line-powered CO meter in the mechanical room and some CO meter on each level of the house anyway.
- Scoundreller 4y ago> have a line-powered CO meter Thank you for stating this. If your furnace requires electricity to run, you don’t need a battery-powered or battery backup CO meter. Unless you have a wood stove or light fires indoors when it gets chilly. Otherwise you’re just wasting batteries.