4 ms·
Duct Size vs. Airflow (2012)
- beastie29a 4y agoEver since buying a house I've been engrossed in this topic along with indoor air-quality and mechanical HVAC systems. There's so much to know about these topics and I feel it helps when dealing with HVAC companies to make sure I'm getting what I want and not be price-gouged. One expert I follow on these topics is Allison Bailes, he has a blog entry on a similar topic of duct design[0]. I find his way of breaking down certain topics simple to follow and enjoy seeing how he's implemented his teachings in his own home. [0] https://www.energyvanguard.com/blog/basic-principles-duct-design/ https://www.energyvanguard.com/blog/basic-principles-duct-de...
- turtlebits 4y agoWhy not get some indoor sensors and DIY? I’m planning to install an ERV and a whole home dehumidifier to see if I can get that ideal indoor air quality.
- alliao 4y agoI can't help but think HVAC is the perfect industry for the limited AI we have right now... it just need to hit a sweet spot of relative humidity and temperature, with constraints given by the assets you have and its' performance envelope given input from mixture of indoor/outdoor air.. but right now HVAC industry is treating relative humidity like some ultimate luxury tier item..
- walterbell 4y agoTerra Bloom has 4/6/8" EC duct fans that can be controlled by wired/wireless remotes and DIY MCU/RPi via PWM, including a tachometer readout of actual fan speed, https://terra-bloom.com/blogs/news/how-to-choose-a-fan-speed-controller-for-your-growroom https://terra-bloom.com/blogs/news/how-to-choose-a-fan-speed... & https://github.com/albahmed23/terrabloom_ec_fans https://github.com/albahmed23/terrabloom_ec_fans.
- 2rsf 4y agoMaybe because relative humidity is more expensive to control? in an ideal case it's just moving and mixing different levels of air temperature and humidity, but in reality you need to de-humidify or add humidity
- thedougd 4y agoPID and other basics of control theory have been around for ages, they're just not used in residential HVAC. Perhaps the limiting factor has been the traditional split system with only on and off states. As we move towards variable speed compressors and fans, we may see more intelligent controls. Maybe an AI can help tune the control constants?
- MichaelZuo 4y agoI found it inordinately difficult to get humidity to a stable point in Canadian winters, because practically no homes are designed with relative humidity in mind.
- turtlebits 4y agoHouses are designed to control/shed moisture, not control humidity. It's fairly inexpensive get a standalone dehumidifier and just set a humidity target.
- MichaelZuo 4y agoA house usually has several rooms. And in Canada humidification demands are much higher in wintertime then dehumidification in summertime. So your looking at literally dozens of humidifiers and dehumidifiers to maintain the optimal 40% to 60% range at all times in the average sized house.
- MengerSponge 4y agoInstrument things and DIY to tune, but start from Passivhaus standards. There's a ton of great developments on ERVs and insulation that could use more attention in the US.
- bombcar 4y agoA lot of it is managing the air barriers (not vapor barriers!) and sealing the house to prevent air leaks. But if you're concerned about air quality there are some major things you can attack first - water heater being electric or forced-vent, furnace being forced vent, etc. The less "burning" inside the house the better off you'll be to start.
- TEP_Kim_Il_Sung 4y agoThe important part of good air shaft design is making them large enough to fit a squad of marines, and yet small enough not to fit biomechanoid xenomorphic invaders.
- arethuza 4y agoIsn't there also an important material selection choice to be made - your ducts (getting a bit Brazil about it) have got to be impervious to angry biomechanoid xenomorphs who can smash through thick steel doors but also easy enough to cut and weld with small handheld tools?
- dekhn 4y agoThis is known as the "Die Hard Aliens Problem"
- 2ICofafireteam 4y agoBonus topic near and dear to my heart: Ducting design is a biggie, but a neglected issue, and the biggest sin I see in residential HVAC, is ignoring a design's peak heating or cooling energy demands and installing oversized heat pumps. The bigger is better mentality in that area results in (sometimes dramatically) shorter run cycles with an unnecessarily large compressor. It's not good for your electric bill or the equipment, and you get a monster motor dimming your lights every 10 minutes. If I had a dollar for every time an HVAC contractor offered me a quote including an upgrade option for a heat pump three times larger than is needed...
- bob1029 4y ago> I feel it helps when dealing with HVAC companies to make sure I'm getting what I want and not be price-gouged. Indeed. I've got a crew replacing my coils & dehumidifier as I type this. If I didn't know what I know about HVAC, the sales rep I worked with yesterday would have absolutely taken me for a ride. Many of the initial questions they ask you when they get to your home are intended to gauge your ability to call out their bullshit.
- owenfi 4y agoAnother good resource: https://homediagnosis.tv https://homediagnosis.tv Their youtube channel/resources focus a lot on testing/verification. If anyone near San Jose / Santa Cruz wants to borrow a blower door and some testing tools for a few days or a week I'll make you a good deal =) -- If you want a non-professional evaluation I'd probably have a day or two of availability in the next few months as well. (I don't have duct testing tools yet, but with notice would probably get them.)
- wodenokoto 4y agoI gotta admit, my first thought was "Duct Size" is a weird name for a distributed work-flow tool[1]. [1] https://airflow.apache.org/ https://airflow.apache.org/
- arvindamirtaa 4y agoGlad I'm not alone
- vb8448 4y ago+1 :D
- _aaed 4y ago2012 is 3 years before Apache Airflow was released
- londons_explore 4y agoAll this assumes airflow to every room all the time. But in real systems, you only want airflow to rooms with people in. And in a residential setting, you can be fairly sure that won't be all rooms at once. Which means ducts can be sized differently, as long as you have sensor vents on the end of each.
- 2rsf 4y agoYou shouldn't stop flow to unused rooms, maybe limit or reduce but not stop. You don't want too high/low humidity or temperatures in one room.
- londons_explore 4y agoWell that's what the sensors are for... I like to have CO2+humidity+temperature sensors in each room, and then when any go out of an allowable range you open the vent. I sometimes also install PM2.5 sensors hooked up to the vent because unattended cooking or toasters can make a lot of PM2.5 and not much of anything else. Also obviously you want the vent to open proportionally to how in-range the measurements are, otherwise you end up with a vent opening and closing every 5 minutes all day long which is very annoying.
- 2rsf 4y agoI saw a Swedish "dream house" TV series where someone installed something like that, it cost a small fortune and I don't see the big benefit in it compared to "normal" mechanical ventilation, maybe with heat recovery.
- londons_explore 4y agoThe big benefit is that heat recovery units only recover ~80% of the heat. And if you want really good air quality in a room, you want 10 air changes per hour or so. So, that means you are losing 20% of the heat in the air every 6 minutes. If you're doing this in the UK with gas heating and outdoor air of 0C, indoor air of 20C, a 2500 square foot average house and 9 foot ceilings, then it costs a whopping £14/day to heat just the heat lost in the heat recovery unit. Considering that you can buy a CO2+temp+humidity sensor for £15, and then only use as much air as is actually needed for the occupants of the house, you can normally reduce this by 90% typically - saving £4000 per year - well worth it for £100 of sensors. Math: https://www.google.com/search?q=700+J+%2F+kg+%2F+Kelvin+*1.2+kg%2Fm%5E3+*+20+Kelvin+*+2500+square+feet+*+9+feet+*+0.2+*+10+per+hour+*+24+hours+*+0.10+GBP%2Fkwh https://www.google.com/search?q=700+J+%2F+kg+%2F+Kelvin+*1.2...
- slowhand09 4y agoWhat a rabbit hole. Lots of house geek info here. Love it. https://russellking.me/2017/09/06/how-to-quickly-evaluate-a-residential-hvac-duct-layout/ https://russellking.me/2017/09/06/how-to-quickly-evaluate-a-...
- HybridCurve 4y agoI am in Houston and AC is a necessity. Most residential AC guys here are awful- they can make a killing in the hot seasons for simple calls to replace a $30 run capacitors on compressors (very common failure, often encouraged by power blips). Most of them do not fully understand duct design and many will pass on jobs to re-do ducts if they can since it is more profitable to focus on break-fix type calls. Because of this, I had to learn about AC systems and duct design myself. Here are some things I have learned which are not often mentioned: - Intake filter flow rates are important, 1" filters have varying pressure drops across them and can account for a significant loss of available static pressure in your system. Most companies do not list this figure on their product, or even provide it. - Return air is far too often neglected in duct design. I have a section of my house which requires %25 of the available air flow to cool but it has no return air path. So if the interior door to that area is closed, the air is instead forced outdoors and the loss is reclaimed on the other side of the interior door from (you guessed it) outdoors. So if a door to an area is barely open and then closes when your system kicks on, you probably don't have adequate return air. - Most newer homes use flexible duct. It is much cheaper and lighter than metal duct work but how it is installed makes a massive difference in how efficient your system is. Flexible ducts lengths which have slight compression (15%) or sag might double the loss for that section. Overall the duct work design and installation is one of the most important aspects of your HVAC system which is the LEAST profitable (earnings/time) to your residential AC guy and therefore, is often neglected. If you want to go deeper I recommend the ASHRAE Fundamentals handbook which covers heat load calculations, fenestration, systems, and duct design. You can pickup a older used copy for cheap. Avoid ACCA guides, they obscure all the underlying math and engineering behind a more simplistic design method based on total 'effective' length calculations which makes duct design difficult to understand intuitively.
- deleted 4y ago[deleted]