15 ms·
Homemade Heat Pump Manifesto (2009)
- unixbane 4y agoHas anyone hacked furnaces yet? They have giant PCBs in them.
- bombcar 4y agoMost furnaces are incredibly amazingly simple and the large PCB is just for reliability and to support the transformers. Many even now are (blower on/off) and (flame on/off). Only the high end ones have variable blowers and flame heights. I know this because before ours was replaced I had to jumper past a bunch of the board to keep it running.
- c_o_n_v_e_x 4y ago>Many even now are (blower on/off) and (flame on/off). Only the high end ones have variable blowers and flame heights. There's a few other safety checks the board will do.. check pressure switche to ensure there is draft before attempting to open the gas valve and light off. There's also thermal limit switches to make sure things don't get to hot if your main blower goes out.
- bombcar 4y agoI’d have to check my new one but often those switches are just in series as a physical disconnect.
- c_o_n_v_e_x 4y agoOn some boards they're inputs as that's what provides the necessary info for the board to provide flash/error codes. Not unusual to see additional standalone limit switches (like what you observed) for extra protection.
- walterbell 4y agoFrom the same forum, a 50+ page thread on DIY ventilation heat exchangers, e.g. 4"x4"x24" window unit that moves heat from exhaust airflow to fresh incoming airflow, https://ecorenovator.org/forum/showthread.php?t=891&page=38#post27793 https://ecorenovator.org/forum/showthread.php?t=891&page=38#... and a home-sized DIY HRV, https://ecorenovator.org/forum/showpost.php?p=26861&postcount=291 https://ecorenovator.org/forum/showpost.php?p=26861&postcoun... > outside temperature is 10,0 degrees Celcius, inside T is 21,1 and incoming fresh breeze (top) at 19,0!!
- walterbell 4y agoMore links via above thread. 2016 pipe design with 3" metal duct inside 4" PVC pipe, https://www.loudawson.com/17884/how-to-build-air-cross-flow-heat-exchanger/ https://www.loudawson.com/17884/how-to-build-air-cross-flow-... 2012 box design with aluminum foil on wood frames, https://makezine.com/projects/heat-exchanger/ https://makezine.com/projects/heat-exchanger/ Elegant $100 commercial window HRV, discontinued (why?), https://www.amazon.com/Bionaire-BAP336M-U-EverFresh-Exchange-Purifier/dp/B001L1BPKQ https://www.amazon.com/Bionaire-BAP336M-U-EverFresh-Exchange... & https://ia904509.us.archive.org/29/items/manualzilla-id-7067964/7067964.pdf https://ia904509.us.archive.org/29/items/manualzilla-id-7067...
- dzhiurgis 4y agoI keep thinking window air cons should integrate heat pump and HRV. Such a simple solution for ton of problems.
- sgc 4y agoOne thing I noticed when reading on diy hrvs in the past, is that many porjects are not taking into account air volume in the two ducts, and the amount of nominal flow for the size ducts compared to the ideal amount of air exchange. A 5 inch duct inside a 7 inch duct is more or less the correct size for many homes: about 50 cfm each direction. I do like the fact that there is a ton of dead space in most attics, where you can just drop a long, well insulated pipe hrv and be done with it for a relatively low cost.
- alexose 4y agoNote that this thread is still active 13 years later! The most recent post is by the OP, and reads: > I want to take a moment to recognize that the Homemade Heat Pump Manifesto has gone beyond 2 million page views. I would like to thank Daox and any other people who may have worked behind the scene to make it possible. > My initial goal was to make available the knowledge and possibility that anybody with a few tools and gumption could convert discarded air conditioners, and dehumidifiers into very high efficiency heat ources, or cooling sources. Through the years, we have received reports of success from many people, living in many states, and countries. > Another goal was to make zero money from this project, to give it away and to encourage others to take it, share it, sell it. > In the beginning I thought that maybe 200 people would find this interesting. Obviously, I was wrong, gloriously wrong.
- layer8 4y agoAnd that is why traditional web forums and their discoverability are great. This wouldn’t work on Reddit or Discord.
- HenriTEL 4y agoWhat makes you think reddit is not discoverable?
- kybernetyk 4y agosometimes whole subreddits get deleted because of $reasons. sometimes I get to a link and a message greets me: this subreddit has been deleted because of no moderation.
- lifeisstillgood 4y agoI understand that in a few years every new build in the UK must have a GSHP (no gas boilers) and the goal is for every house to have something like it. I think this manifesto is a piece of genius - I think I shall be studying :-)
- Gordonjcp 4y agoI wonder if whoever thought that up has ever been to the UK?
- helsinkiandrew 4y agoIts a UK government plan so yes, why do you ask?
- Gordonjcp 4y agoWell, it doesn't sound like they know much about the geography or geology of the UK, quite frankly. How is every house builder going to afford a million quid borehole?
- deleted 4y ago[deleted]
- n4r9 4y agoI don't think the original claim is quite right. The UK govt is banning new gas boiler installations after 2025, but I believe there's a range of alternatives such as an air or ground source heat pump, or a hydrogen boiler. From what I've read through, replacing my boiler with a gshp would cost in the tens of thousands, not a million pounds.
- bombcar 4y agoHow would a hydrogen boiler work? Hydrogen trucks deliverying? Is the UK piped for hydrogen? Electrolizing water on site?
- diordiderot 4y agoI'm relatively young but this link feels like what hackernews is supposed to be. An ugly forum post of someone hacking something together
- omgwtfbyobbq 4y agoEcorenovator's great. Ecomodder has some pretty good stuff too.
- inferense 4y ago> Where did you learn to invent stuff like this? Lots of reading, being willing to try something, welcoming failure as also a learning moment.
- Roark66 4y agoIt is a very interesting thread, but reading 100+ pages of a forum thread to find the details of the project is _hard_. I would definitely like to read a detailed description of his pump unit.
- VBprogrammer 4y agoI've read it before and it's got some cracking info in there. One of my favourite bits was him using propane as a purge gas to get better quality brazed joints, though interestingly he baulks at the idea of using propane as a refrigerant gas!
- bagels 4y agoSounds dangerous.
- implements 4y agoIt's a standard refrigerant gas for some settings: https://www.agas.com/uk/products-and-services/refrigerants/r290-propane/ https://www.agas.com/uk/products-and-services/refrigerants/r...
- theelous3 4y agoNo the brazing sounds dangerous. How does it not ignite?? Brazing is done with high heat open flame. Unless it's just for back purging? But that sounds even more dangerous - intentionally building up a propane resivoir behind the braze.
- jonititan 4y agoProbably because you need sufficient oxygen for combustion. The propane would only ignite where it comes out and mixes. Once the flame travels into the purged pipe it will probably die out for lack of oxygen. Ticklish though I'm sure to do it properly and safely.
- 4y ago
- cyber_kinetist 4y agoAh, the vive of people on the Internet talking for over a decade on an old phpBB forum thread... A bit off topic, but I really think the existing forum sites aren't really that incompatible with "younger" people, and might have a renaissance later on (looking at how they are using Discord in a similar manner!) It's just that these old forum sites have lots of UI clunkiness that deter people from browsing or joining the site (older people who kind up grew up with phpBB might be accustomed to these sorts of jank, but you shouldn't expect someone who weren't in that era to be accustomed to it.)
- VBprogrammer 4y agoI still use a couple of them for niche interests. The one thing that annoys me is that they still make uploading photos a chore. Usually you have to resize the image your self to get under some pathetic size limit. It's enough that people tend towards text when a picture or a drawing would be much better.
- betwixthewires 4y agoWhen you're a guy running a long lived online community on a $100 a year VPS you avoid storing media as mush as possible. There's a reason photo bucket sites used to be so popular.
- OJFord 4y agoMaking it not 'a chore' though could mean a nice frontend to upload to some such photobucket site and embed the result. Then you also avoid the annoying 'you must create an account to view attachments'.
- bombcar 4y agoSome of the forums have features to do that on upload - you just have to configure it. Sadly most of the admins for these type of fora are just learning as they go.
- Nition 4y agoThis is a wonderful thread, thanks for sharing it here. > "The kicker is, that the smallest I have been able to find is four ton (48,000 BTU/hr). So this means that in order to proceed with the project, I'll have to build my own heat pump. In HVAC, bigger is not better... just slightly smaller than big enough is best, economically speaking." Is he saying here that a heat pump that's too large for a space is less efficient at heating, or is he just saying that a bigger one costs more to buy? If it's the former, can anyone here tell me why that is? It's hard to Google since it gets mixed up with other info like "heat pumps are less efficient at very low temperatures" etc. I would have thought they'd end up the same. The only reason I can think of is that a bigger one will maybe turn on and off more often to maintain temperature than a small one that's on all the time struggling to keep up. Edit: Thanks all for the excellent responses.
- ArchitectAnon 4y agoI think it takes a while for the juices to equalise and reach equilibrium before it’s running at max efficiency. You don’t want a duty cycle of say 15mins. You want say 1.5hrs. Something like that. (Numbers very hand wavy this is not my field directly) With an over designed system it stops and starts too quickly and this invalidates the warranty on commercial systems.
- fest 4y agoModern heat pumps drive the VFD and circulation pumps as needed (i.e. the pumps run slower when the heat demand is low). The main factor for good efficiency is low output temperature- underfloor heating works at ~35 deg C, radiators work at ~55 degC (because of smaller surface area). I sized my heat pump based on historical data of heating oil /diesel consumption- since I had the data of past two winters, I could reliably determine the maximum continuous heat requirements for my house.
- lazide 4y agoIt also makes the environment itself uncomfortable in many cases - excessively drying the air, or causing weird moisture/condensation issues (as it won’t fully cycle the air in the house before stopping). Essentially, you want your HVAC system to run for long enough it’s a gradual transition in temperatures inside and the equipment can run for awhile each time it needs to run to avoid the start/stop problems and let it ‘settle in’.
- haunter 4y agoI have zero knowledge about the topic but I wonder how NA specific is this thing? As far as I’m aware houses built with thin wood walls are more prevalent there, like in the original example. I live in a similar aged house (maybe a bit older) in Europe but we have 1 meter thick stone walls. We don’t have AC or ceiling fan but house always keeps cold in the summer and warm in the winter. I like the topic but curious how would that work with stone wall houses, especially like my example old style ones with thick walls
- bagels 4y agoOne meter! Those are quite thick walls. Is it solid?
- haunter 4y agoYes of course. There is an outside insulation layer applied some years ago but otherwise it is as built in the 19th century
- phinnaeus 4y agoIndeed, that seems absolutely insane. Like a castle that would need to survive some sort of siege. Land is expensive where I am and I cannot imagine wasting that much on such insanely thick walls. I want a picture. Walking through the front door must feel like going through a tunnel.
- bombcar 4y agoI’ve seen some that are basically build as two concrete block or brick walls, and the center are was filled with rubble stone and dirt. This is similar to an “earth house” and is very comfortable where the average (or basement) temperature is comfortable. The walls make an insane amount of thermal mass and the temperature inside changes very slowly.
- ComodoHacker 4y agoIt's not insane. I currently live in a house where some older rooms have 0.9 meter adobe brick walls. These were built in mid-XX century, when this was normal. Now we have better materials and don't need that much width.
- ianbooker 4y agoTo aid the discussion: There are multiple kinds of heat pumps used for homes, mainly air-to-water and water-to-water. Since the post is 12 years old, the availability of air-to-water solutions may be understated. At least in Europe it is now quite common to find them in front of new homes. Placed and looks like an AC unit, sounds like a laptop from 2005.
- ArchitectAnon 4y agoOne note of caution, he describes removing the lath and plaster and inserting eps insulation. It didn’t mention if he did this, he might have done, but it’s important to have a continuous taped vapour barrier on the warm side of the insulation to prevent water vapour from passing through, condensing on the timber structure and causing it to rot. Also ventilate the cold side of the insulation or a least have a gap to form a capillary break with the cold outside wall. I’ve seen a few badly done insulation jobs in timber buildings that have needed floor joists and studs cut out and replaced. It only takes about 15-20 years.
- OJFord 4y agoLath & plaster does not form a vapour barrier; deliberately not in most cases (there was perhaps some crossover when more moderm building techniques were still using lath and plaster) - old houses need to 'breathe' as they say, moisture needs to be allowed to move between inside and out. They can be warm & dry, but the way to achieve it is (paradoxically) porous materials.
- ArchitectAnon 4y agoYes of course, but I was thinking more in terms of DIYers jamming a lot of non-breathable eps into old houses. Probably better to say consult someone who knows what they’re talking about before you internally insulate your old house.
- bombcar 4y agoYeah insulation that is a vapor barrier shouldn’t replace insulation that wasn’t without considering the effects. You can use something like rock wool (in batts or panels) to get insulation that is still vapor permeable and water resistant.
- forgetfreeman 4y agoI'm glad someone addressed this as I cringed visibly when I got to this part of the post. I'm very much hoping someone with actual experience with controlling moisture stopped this person before they completed this installation. If not, that house is the residential equivalent of a dead man walking.
- fest 4y agoI am currently installing a Thermia Calibra ground source heat pump (installers are apparently too busy). When I looked at the insides of the pump, the simplicity of construction was surprising- I could readily understand whats going on, as it consisted of off-the shelf parts made by other companies- compressor, circulation pumps, VFD and heat exchangers.
- aivisol 4y agoI second to that. Just got same model installed few weeks ago and was having exact same thoughts. However, now I start to think that devil is in the details (as always). And it has ton of details, which probably have cost thousands on people hours to design, test and implement. Most are related to how to make it work with maximum efficiency while consuming as little power as possible, some are safety related, etc etc. And the build quality is outstanding, it works flawlessly so far, no complaints. Despite the steep price, one of the best investments I have made recently.
- fest 4y agoYeah, I have travelled that road too often (hmm, looks simple, I bet I can make it for half the cost- and a year later I have spent way more even disregarding the cost of my time and still only have a barely working thing) to know how that would turn out :)
- sethammons 4y agoHN loves heat pumps; I'll never have one again - utter shite. I lived in the mountains of Southern California. As part of an FHA loan in buying my childhood house from my dad, we had to "upgrade" from a swamp/evaporative cooler and wood burning stoves and went with a heat pump. The unit and ducting just couldn't keep up. It sighed out slightly warmer/cooler air and, when it kicked on, it pushed outside-temp air into the house that, in winter, would take the unit over an hour to bring the house back to its starting temp, let alone warm it. It really sucks to be cold and to have to get colder before a chance at warming up. It was similarly lame at cooling, though it would keep the house from sweltering if started before sunrise. Temp range outside: 20-40s in winter, up to 90s with a couple of days in the 100s in summer. We went back to the wood burning stove and swamp cooler.
- ricardobeat 4y agoWait, why would the unit pull fresh outside air in? Shouldn't the ratio of recirculation be adjustable?
- sethammons 4y agoThe venting was exterior to the house and was heavily influenced by outside temp
- timbit42 4y agoI'm starting to wonder if you were scammed. That's not how modern air-to-air heat pumps work.
- stephencanon 4y agoIt sounds like a lousy ERV install erroneously described as a “heat pump”.
- c_o_n_v_e_x 4y agoEither that or some kind of bad fresh-air damper / economizer system (either failed or never configured correctly).
- 0x53 4y agoI have been doing a ton of research on building my own GSHP lately and so this is a great resource! However, what I have found in the process is that for well insulated homes GSHP probably doesn’t make sense. Originally I was considering buying a kit from this site: https://www.123zeroenergy.com/pricing/geo-thermal.html https://www.123zeroenergy.com/pricing/geo-thermal.html But like it says on the page, because air source heat pumps have been getting a lot better they no longer sell the kits. There are a couple of individuals on YouTube who have used similar GSHP kits and had good success. The main challenge is that you need to dig 100ft of deep trenches per ton of cooling. Edit: should be 300ft not 100
- cycomanic 4y agoWe just build a house on the west coast of Sweden and we initially considered both a ground or air heat pump. Essentially our builder said with modern houses and heatpumps going for the ground heat pump was really not worth it. Their efficiency gain only becomes significant at outside temperatures below 10 deg C and there were just not enough days of such low temperature. Instead it is better to invest that money into a solar installation.
- cassepipe 4y agoNot to say you were wrong since in making that choice but with climate change days of extreme temperatures in both directions will become ever more common so so you may have considered it an investment into the future. Of course you may have other problems by then (a reliable source of food for example)
- arinlen 4y ago> (...) with climate change days of extreme temperatures in both directions (...) This sort of take is unwise. It makes zero sense to invest today in domestic systems with the expectation that at some point in the future there will be extreme events a hand full of times throughout the year. The benefit of shaving a fraction of a percent from the baseline outweighs multipercent gains of hypothetical extreme events that happen a few times a year.
- frankus 4y agoSlightly unrelated, but there’s a proposal to use a shared ownership/utility model for the borehole/trench component and install it in e.g. the street: https://heet.org/energy-shift/geomicrodistrict-feasibility-study/ https://heet.org/energy-shift/geomicrodistrict-feasibility-s...
- kortex 4y agoFascinating! I would have not expected that maintaining annual thermal balance would be as big of an issue as it is.
- post_break 4y agoMy new dryer is a heat pump. Uses less than half the energy my previous one did. It does take longer to dry clothes, but it's much gentler on the clothes so it's a perfect trade off for me. I'd love to do a heat pump like this for the house but there is so much oil pipeline around me and there's no way a truck with a pile driver can reach my back yard.
- dzhiurgis 4y agoHot water cylinders can have heatpumps too! Wish we found a solid way yo harvest heat from waste water. So much energy is wasted on showers - similar to EV driving at highway speeds.
- throwaway4220 4y agohttps://en.m.wikipedia.org/wiki/Countercurrent_exchange https://en.m.wikipedia.org/wiki/Countercurrent_exchange A lot of mammals do this including humans. Don’t know if there’s a drop in plumbing shower solution.
- bombcar 4y agoWe do it. It’s not yet economically worth it but I’ve seen installs. I can’t find it but I saw one that was designed to let a massive shower run continuously with very little heat loss - the water coming out the end of the drain was as cold as the inlet water from the main. https://en.m.wikipedia.org/wiki/Water_heat_recycling https://en.m.wikipedia.org/wiki/Water_heat_recycling
- theluketaylor 4y agodrain water heat recovery is already a thing. It's code for new builds in British Columbia, Canada. It's only expensive due to the amount of copper. The actual install has no moving parts and is completely passive. https://www.nrcan.gc.ca/energy/products/categories/water-heaters/14568 https://www.nrcan.gc.ca/energy/products/categories/water-hea...
- dzhiurgis 4y ago
- voisin 4y agoIs there any way to combine a ground source heat pump with a well?
- bombcar 4y agoSome of them are basically multiple bidirectional wells (when installed vertically in a colder climate) so drilling one more for a wellhead is probably possible.
- voisin 4y agoI've got wells on my property. Rather than drill more wells, I am wondering if there's something that could be put in the well to utilize the stable water temperature down below to heat exchange? Seems like there would be a big market - lots of people on wells are heating with oil or propane or electricity at massive costs.
- bombcar 4y agoIt would depend on the well and the “heat availability” (not a technical term) and how deep it was. I suspect it could work but it’d be marginal enough as not to be worth it compared to straight air heat pump or an actual field (similarity could a heat field and a septic field be installed at the same time ,,,)
- voisin 4y agoI understood, perhaps incorrectly, that the ground below the frost line is stable year round and if air source heat pumps work more efficiently down to -10C, we know the water isn’t that cold (otherwise it would be ice), so wondering if the efficiency threshold is the same for ground source heat pumps?
- bombcar 4y agoThat's why the ground ones are dug vertically sometimes, they can get to stable temperatures. However, a well may be "just poking" into that territory so you get the right temperature, but not enough surface area to do much heating/cooling.
- jhallenworld 4y agoThe US Senate just approved an HFC ban. So which refrigerant should be used in the heat pumps? Can we get HFC-free heat pumps today? See https://www.danby.com/blog/danbys-commitment-to-remain-100-hfc-free/ https://www.danby.com/blog/danbys-commitment-to-remain-100-h... http://hvacrfundamentals.blogspot.com/2019/06/appliances-with-flammable-refrigerant.html?m=1 http://hvacrfundamentals.blogspot.com/2019/06/appliances-wit... Looks like r600a, iso-butane is already in use.
- wongarsu 4y agoI would assume any refrigerant in use in air conditioning works just fine, based on heat pumps being air conditioners ruining in reverse
- AvocadoPanic 4y agor744
- usrusr 4y agoReminds me of a surprising armchair heat macguyvering idea I've had: if for some reason you are stuck with resistive heating, you could use an old fridge as your resistive converter, with the cold end inside (cold end outside would be an actual heat pump, but probably not a good one and very limited in placement, likely losing more to the insulation downgrade from the placement): open the door just enough to get the inside walls below condensation of your current humidity level, collect the condensed water in a way that it doesn't just evaporate again but can be carried to the sink. Why? Slightly less air replacement required to fend off mold, slightly more heat created, because the condensation is the inverse of evaporative cooling. Haven't done the math but I think it's safe to assume that the benefits would be tiny, but if, for some reason, you were limited to resistive heating, doing it this way would be slight ly less bad.
- Gare 4y agoMy humidifier uses about 3 liters of water per day for 40m2 apartment during winter, to keep the humidity at acceptable 40%. Otherwise it's extremely dry inside.
- fsh 4y agoThat's just a very ineffective dehumidifier.
- sgc 4y agoExcept you usually have a very dry environment when heating due to the lack of moisture in the colder environmental air, and need to add moisture to avoid falling out of healthy humidity levels for human beings.
- usrusr 4y agoDry air is less unhealthy than moldy air.
- sgc 4y agoWe are talking about large amounts of moisture that need to be added to the air when heating. There is 0 risk of mold in that situation. Ideal humidity: General recommended range: 40-60%; ideal/goldilocks humidity, 50%; mold conducive conditions: 60%+; air when heating: often ~30%.
- namuol 4y agoI’ve heard that air source heat pumps can be very effective too, and far simpler to install. I wonder if there’s any discussion about converting ordinary AC units into reversible units, which supposedly is basically all an air source heat pump is.
- ajross 4y agoExterior heat pumps used in humid or below-freezing environments need some kind of defrost mechanism, just like a refrigerator. Otherwise your coils end up clogged with ice and the system stops working. The compression cycle is indeed symmetric, but the second order design constraints are quite different.
- theluketaylor 4y agoModern setups are really good about managing frost buildup and can be more efficient than resistive heat down to -20C. Waste heat from the compressor is often used for the defrost.
- VLM 4y agoDoes anyone have any financials on this? I get that if your heart is set on having a heat pump you need a heat pump, and that's the end of all financial consideration. But how does, say, $10K of heat pump compare to $10K of insulation and better windows/doors/roof, or $10K of solar panels and cheap ultra-low-tech repairable all-electric HVAC, or $10K of some other form of physical investment I'm not aware of?
- ajross 4y agoA heat pump is 3x more efficient at heating than a resistive electric heater, making it just about a wash with a gas furnace in most markets in terms of sustained cost. The hardware is more expensive, but not THAT much more expensive. When you include installation costs and amortize over a 20 year system life, the overhead is non-zero but quite low (10% or so). If you guess that gas is going to be more expensive in the coming decades where electricity is futureproof, it seems like a good bet to me. Ask me in 20 years.
- xani_ 4y agoI wonder how's the failure rate compared to oldchool types of heating. The longest warranty I can find on the market is 10 years
- ajross 4y agoThe moving parts are identical to an air conditioner. Those go for decades reliably.
- xani_ 4y agoWe had 2 in our office closet datacenter and they definitely needed more maintenance than what I remember our coal burning furnace did
- LurkerAtTheGate 4y agoLived & owned homes for 20 years in an area where ASHP are standard installs as the climate range meant 100% of normal (outside of freak polar vortex) heating and cooling was covered by the heat pump. Inexpensive part failure is common annually - usually capacitors and fan motors. Usually expensive part or system failures occur around 10-15 years.
- astrostl 4y agoI know two major things about heat pumps: 1) their owners insist they are the greatest thing ever and 2) nobody in the midwest seems to sell them (at any price) I don't quite know how to reconcile those two things.
- timbit42 4y agoThey are great if you are looking to use electricity to heat because they are 3 to 4 times more efficient than resistive heaters. It depends on the price of electricity and other heat sources in your area. If you live in the north where temperatures go below -15 Celsius, air-to-air units aren't as great because they lose efficiency as it gets colder outside. My heat pump has a COP of 3, meaning it can generate as much heat as a resistive heater using 1/3 the electricity, but it shuts off at -15 Celsius because below that point it is less efficient than resistive heat. If your heat pump has a COP of 4, you might get to -25 Celsius before it is less efficient than a resistive heater. Better, but more costly, heat pumps use in-ground water, either from a pair of wells, or from a deep pond that won't freeze to the bottom, or from many meters of water pipe buried deep enough beneath your lawn to not freeze in the winter. Because of the depth, they always have access to the earth's heat so they don't lose efficiency in the winter. The Technology Connections YT channel has a couple of good videos about how them: 1. https://www.youtube.com/watch?v=7J52mDjZzto https://www.youtube.com/watch?v=7J52mDjZzto 2. https://www.youtube.com/watch?v=7zrx-b2sLUs https://www.youtube.com/watch?v=7zrx-b2sLUs
- __turbobrew__ 4y agoI don’t think the underwriter on my house insurance would be happy with me hacking together a bunch of parts to create a bootleg HVAC system. The project is cool, but if the project caused a water leak or fire you are probably screwed and wont get anything from the house insurance.
- JoelMcCracken 4y agoThis is exactly why I keep coming back to this website
- nqzero 4y agotangent: for a small air-to-air heat pump, what's the best commercially available coefficient of performance (COP) for a zero-delta-T ? all the common ratings that i've found online refer to COP at a non-zero delta-t over a ranges of conditions. to illustrate my question, if you needed to pump heat from 70°F indoor air to 70°F outdoor air with a 1-ton unit, what would be the best COP you could achieve in 2022 ?
- paulkrush 4y ago"my stove has 35,000 burners" Holy Sh*t! I wounder how many BTU's each burner has? That's a big stove!