by cogman10 4y ago
Combining heat + electrical energy makes the stats really muddy.
Does 10% of the burned energy end up as electricity? Or is it more like 30%? Hard to tell.
The real question is, what do you do with that heat when you don't want it? What's the efficiency then?
I will say, it would be pretty neat if one day we could get a mutli-device heat pump system going. Wouldn't it be cool if the heat pulled from your home was dumped into the water heater before being extracted vented? Or if instead of your fridge having a heat pump, it simply tied into a home heat pump system?
This sort of thing would call for a centralized compressed lines. And, perhaps the reason that's not happened is because we don't want to worry about what happens when toxic gasses discharge into the home.
Still, would be pretty neat if we could have a centralized cold and hot compressed gas system for buildings.
- aftbit 4y agoCommercial and larger residential buildings often have water at various temperatures as a utility. There will be a machine room that has large water-to-water heat pumps, then a chiller tower on the roof that takes hot water, evaporates some and cools the rest, then returns it to the hot-side heat exchanger. The cold side will circulate water around the building, where it will be used in water-to-air heat exchangers on the room or unit level to cool the building. In most climates, larger buildings need more cooling than heat, but doing the same thing with a hot water system is quite common as well.
- Dylan16807 4y ago> Combining heat + electrical energy makes the stats really muddy. > Does 10% of the burned energy end up as electricity? Or is it more like 30%? Hard to tell. > The real question is, what do you do with that heat when you don't want it? What's the efficiency then? And also, because electricity can pump heat so effectively, 10% efficiency in electricity is more valuable than 30% efficiency in heat.
- Schroedingersat 4y ago> This sort of thing would call for a centralized compressed lines The exchanger doesn't need to be the working fluid. You could have Freezer | Fridge | Ground | 30 degree water | 70 degree water With each | indicating water or another coolant in an insulated pipe. Insulate each reservoir and place it inside/outside depending on climate. Insulation on longer runs of piping might need to be exotic and expensive (aerogel or double walled vacuum sections), but there wouldn't be much of it. We already do something similarish for some AC systems