It's not like they are drop-in replacements for whatever you've got, either. I was interested in these about 15 years ago when I bought a house. They want a de
by saxonww 5y ago
It's not like they are drop-in replacements for whatever you've got, either.
I was interested in these about 15 years ago when I bought a house. They want a dedicated circuit with a 240V outlet and 40 or 50 amp breaker. My house has a gas range, so I don't already have a 240V outlet there, and I've only got 100 amp service at the panel - which claims 100 amps is the max it's rated for. I decided it was not worth the hassle.
- bluGill 5y agoI've had electric stovs with 100 amp service before, not a problem even if the ac was also on. 40 amp is standard for kitchen stoves so it is very common ,but obviously if you have gas they won't install wires for electric.
- seanmcdirmid 5y agoI bought a newer home (2016) with a gas range and it doesn’t have the wiring either. We desperately want induction plus a outdoor vented range hood, so we are considering a partial remodel to do it. The idea is to bring in an electrician, replace our 150A panel with a 200A one, bring up wiring for induction into the kitchen, and wrap wiring around the house for a level 2 EV charger (another want, might as well knock it out together if we have to get an electrician in anyways). My house was built 6 years ago but is already outdated in this respect. Replacing the panel is a pain as it requires shutting of electrical service for the day and an inspection from the city when they switch it back on. At least our meter and outdoor wire to the grid are already 200A…I hope.
- danans 5y ago> replace our 150A panel with a 200A one, A 150A panel should accommodate both your induction stove and EV charger. The stove's 50A rating assumes you are running all burners are running simultaneously, which is rare. You need 200A if you going fully electric (for hot water, HVAC, oven and clothes dryer).
- namibj 5y agoAlso most stoves (at least here) seem to allow de-rating by configuring them to self-limit their current draw to accommodate breakers/circuits not sized large enough to handle their full capacity.
- seanmcdirmid 5y agoOur hot water is gas, but our HVAC (heat pump), dryer is already electric. The oven would be electric also, but it’s rarely used. Anyways, I would let an electrician make the call, but my feeling is that EV level 2 charging and induction would put us over when a 150A panel could handle.
- danans 5y agoYeah, heat pump and dryer can push you over, especially if you are in a colder climate. Miele makes a 115V/20A heat pump dryer that you might consider even if you go to 200A.