4 ms·
You did the wrong calculation. Either you used a very pessimistic estimate for drive speed and forgot to factor in the increase in linear density, or you used
by Dylan16807 6y ago
You did the wrong calculation.
Either you used a very pessimistic estimate for drive speed and forgot to factor in the increase in linear density, or you used a relatively accurate calculation and mixed up megabytes per second with megabits per second.
- effie 6y agoWith 200MB/s I'm getting one week as the lower limit for rebuild time. If the drives are used heavily while rebuilding, this can go much longer.
- Dylan16807 6y agoThe increase in platter density means you should expect numbers more like 600MB/s. > If the drives are used heavily while rebuilding, this can go much longer. True but that's a separate factor and depends on how the array is laid out.
- effie 6y agoYou are right, let's hope those 600MB/s will be the case.