Now at level 3: Situation Critical: "has declared an EEA 3. Energy conservation is critical. Rotating outages are underway to reduce demand on the electric sys
by Scoundreller 6y ago
Now at level 3: Situation Critical:
"has declared an EEA 3. Energy conservation is critical. Rotating outages are underway to reduce demand on the electric system. We urge Texans to put safety first during this time. Traffic lights and other infrastructure may be temporarily without power. 01:25:40 150221"
https://twitter.com/ERCOT_ISO https://twitter.com/ERCOT_ISO
"Rotating outages primarily affect residential neighborhoods and small businesses and are typically limited to 10 to 45 minutes before being rotated to another location."
http://www.ercot.com/eea_info/show/26464 http://www.ercot.com/eea_info/show/26464
- Rapzid 6y agoI'm curious how they coordinate between the transmissions providers as to what gets cut off when and by whom.
- Scoundreller 6y agoThe second link says: "each utility is required to lower the demand on its system based on its percentage of the historic ERCOT peak demand. "each utility is responsible for determining how to implement the required demand reduction, most utilities use rotating outages for this purpose." There's about 25 different utilities, so who knows what each does. I'm surprised voltage reduction isn't used. It's very effective at reducing resistive loads (ie: heaters and incandescent lights).
- JimNasby 6y agoThe grid has basically zero capability to change the voltage; frequency is all that matters. Frequency is so low that in the past hour any power line time base has fallen over 5.5 seconds behind. That’s a massive drop in frequency.
- Scoundreller 6y agoIt's a tool where I am. The grid operator does tests for 3% and 5% reductions: https://www.ieso.ca/Corporate-IESO/Media/News-Releases/2019/07/IESO-to-Conduct-Routine-Voltage-Reduction-Test https://www.ieso.ca/Corporate-IESO/Media/News-Releases/2019/... Would be very effective with the space-heater (or oven?) driven demand right now in Texas. Not effective for A/C-driven demand (motors will draw more current).
- Animats 6y agoNo, voltage can be dropped a bit. "Brownouts" are a thing. But they're less effective than they used to be, because everything with a switching power supply will draw more current if the input voltage drops. That's now a big fraction of the load.
- LeoPanthera 6y agoSurely it’s not a big fraction of the load tonight. This whole problem is being caused by heaters.
- puetzk 6y agoBut heaters on thermostats will just run more if they are putting out less wattage. So across your whole population of houses, you won't move that part of demand much (maybe a few were already running at 100% duty cycle).
- DavidPeiffer 6y ago>Frequency is so low that in the past hour any power line time base has fallen over 5.5 seconds behind. That’s a massive drop in frequency. Out of curiosity, where did you find this?
- atian 6y agoI’m in North Texas (Oncor) and my place just got hit by the rolling blackout 3 minutes ago (1:44am). See http://www.ercot.com/content/cdr/main/currentDayForecastSystemLoad.png?uniquenessFactor=1613377458767 http://www.ercot.com/content/cdr/main/currentDayForecastSyst... for dramatic shedding of load. Edit 1:54am - First blackout lasted exactly 10 minutes. They got this down to a tee. Edit 2:37am CT - Second blackout started. Edit 3:00am - Second blackout ended. Edit 3:17am - Third blackout started.
- enraged_camel 6y agoI lost power at 2 am. It’s 2:48 am and still no power...
- atian 6y agoI’m charging my portable batteries with the power left on my Macbook.
- godtoldmetodoit 6y agoSame here, been an hour and a half with no power in Austin.
- enraged_camel 6y agoAustin here also. 8.5 hours and counting. They need to find a solution soon...
- nottorp 6y ago> "Rotating outages primarily affect residential neighborhoods and small businesses and are typically limited to 10 to 45 minutes before being rotated to another location." I don't understand. Here they shut down a couple large factories (that have agreed beforehand to emergency shutdowns) when there are capacity problems. Those eat so much power that it usually solves the problem. They don't shut down power to residential just for capacity, if you're without power at home it means something blew up on the path that delivers to you. Also, how can a gas pipeline freeze? Almost everyone is heating with natural gas here, we have a cold wave, and the only question is if they can deliver enough volume. Which is again fixed by shutting down some large industrial consumers, not by freezing homes.
- bombcar 6y agoThey've already done that - that is EEA 1 and 2 (1 being voluntary shutdown, 2 being involuntary shutdown). They've asked everyone who CAN go to backup generators (think: hospitals, datacenters) to do so. If short-term shedding of residential load doesn't work, the next step is to blackout commercial players - think Walmart, etc. Those usually occur for longer periods of time and have security risks involved. Natural gas pipelines have some water in them, they can freeze if they're not buried deep enough.
- nottorp 6y ago> the next step is to blackout commercial players Yeah, my point is they have the order wrong. They're shutting down residential first with the associated health risks instead of shutting down commercial which will just send people home for a day or three.
- bombcar 6y agoI was wrong - there is no EEA 4. It's up to the local utilities to determine how to shed load; I suspect many office parks are already without power (but at 4 AM they're also probably not using much power).
- 6y ago
- bombcar 6y agoLook at the projected capacity graph on the main page - they expect to be 10 GIGAWATTS short by 9 AM!