And we’re still doing storage wrong. My A/C could have a reservoir of refrigerant that is compressed overnight. Same for my fridge/freezer. Or my fridge could m
by Scoundreller 6y ago
And we’re still doing storage wrong. My A/C could have a reservoir of refrigerant that is compressed overnight. Same for my fridge/freezer. Or my fridge could make ice that’s held until peak hours. My deep-freezer could have an ultra-chill zone that runs at night. My dryer could run in slow-mode if I turn it on at a dumb time. My water heater (even a gas one has a 250w powered vent) could ultra-heat during off-peak. My dishwasher could auto-delay until 3am......
We don’t even need “smart” 2-way comm appliances. Just a weather forecast should work well enough to predict.
- bigbubba 6y agoFridge/freezer combos are already a compromise design that sacrifice efficiency for floor space. Chest freezers that open from the top are far more efficient (the cold air doesn't all pour out when the door is opened.)
- Scoundreller 6y ago...and don’t get me started on freezer-below units. Who wants a system where relatively warm fridge air sits right above the cold freezer?
- aidenn0 6y agoFWIW, my gas water heater has a chimney, not a powered vent.
- Scoundreller 6y agoProbably bigger exhaust pipe (ie: not 3?” PVC) and straight up so it always acts like a solar chimney or Venturi pump. I’m unsure which is more efficient in the end.
- MertsA 6y ago>My A/C could have a reservoir of refrigerant that is compressed overnight. Not unless you want to just vent all of the refrigerant during operation. You need to keep the suction side under low pressure otherwise it'd just stop boiling the refrigerant. >My deep-freezer could have an ultra-chill zone that runs at night. That'd be making it much less efficient so even if you can get away with some load shifting here you'd be increasing the load substantially in order to do so. Also this would cause large repeated temperature swings for everything inside, might not be too big of an issue once it's already frozen but still, undesireable. >My dryer could run in slow-mode if I turn it on at a dumb time. Your dryer could be replaced by a much more efficient design such as a heat pump dryer or a mechanical steam compression dryer. >My water heater (even a gas one has a 250w powered vent) could ultra-heat during off-peak. Safety devices make this a complete non-starter. A mixing device to lower the output water temperature can fail and probably eventually would fail stuck all the way hot making this a substantial burn hazard. Even ignoring this, all water heaters have a temperature and pressure relief valve and increasing the water temperature to e.g. 200 degrees instead of 140 substantially reduces the safety margin you have between normal operating conditions and catastrophic failure of the tank (a sizeable explosion). Also you're not really gaining a lot here, you could just use a standard water heater timer to turn it off during peak hours and rely on storage capacity. Increasing the setpoint from 140 to 210 assuming ambient cold water temperature of 70 degrees only doubles your hot water equivalent capacity. I suspect it would be cheaper to increase the tank size and not have to deal with the more challenging operating conditions. Also, again, a much better solution is just widespread adoption of heat pump water heaters. For most homes you don't need the higher output of a resistive water heater and even if you did every heat pump water heater I've seen still comes with resistive heating as well if it can't keep up with demand. The decrease in energy bills pays for itself over the lifespan of the appliance. Personally I've always wanted to see a practical combined heating and refrigeration system for a home that could tie in a fridge, HVAC, hot water heater, etc via CO2 refrigerant.
- throwaway201103 6y ago> I've always wanted to see a practical combined heating and refrigeration system for a home that could tie in a fridge, HVAC, hot water heater, etc via CO2 refrigerant. This has been done commercially for decades, but my guess is that the potential savings at home residential scale are not enough to offset the cost and additional complexity.
- BlueTemplar 6y agoMy water heater, dishwasher, washer and dryer are already timed to work during off-peak - what are you waiting for ? (I'll have to check about fridge ice, good idea!)
- Scoundreller 6y agoMaybe the new ones have it, but most of the ones I’ve used (manufactured over last 5-15 years) don’t have it, or have a single delay setting and that’s it. This is in sorta-cheap electricity Canada.
- BlueTemplar 6y agoWell, I guess I'm cheating - only my water heater gets an automatic "off peak" signal, coming via the electric power grid. For all the others, since I don't run them every day, I just have my watch reminding me when it's "off-peak time" and/or delay them to night off-peak...