8 ms·
Sort of on the subject, i've seen a brochure for a specialty product marketed to law enforcement. It's meant for use with the seizure of live, powered on deskto
by walrus01 6y ago
Sort of on the subject, i've seen a brochure for a specialty product marketed to law enforcement. It's meant for use with the seizure of live, powered on desktop PCs and similar that have a high likelihood of full disk encryption.
Essentially it's a medium sized double conversion ups, with a really high quality sine wave inverter, and some electronics that can match phase with a live 120vac 60Hz circuit. And a tool kit which consists of the insulated electrical hand tools needed to do a midspan removal of the cable jacket and splice into the wires in an ordinary PC power cable. The person using it is of course supposed to be trained in advance, and competent at the process of attaching the UPS to the live circuit.
- throwaway744678 6y agoWouldn't it be safer to open the case and connect some kind of battery + adapter after the power supply?
- walrus01 6y agoSplicing into the many wires that is an atx+12v power connector, between the output of the power supply and the motherboard is way more fiddly than just dealing with the hot and neutral on an ordinary $5 PC power cord. You could also never be certain what weird ziptie and cable management system (or lack thereof) might exist in a home built x86 PC case, or if there's any room for hands to work at all... I think the thing I saw is also meant to deal equally well with a commodity x86 PC built from parts, or an Intel NUC size thing, or a corporate desktop machine with proprietary internal wiring like a slimline Dell, Lenovo, HP, etc.
- ajross 6y agoSafer for the operator? Sure. But certainly not for the device, if you're trying to keep it operating. An ATX power supply has 24 pins at 5 different voltage levels (plus any auxilliary power connectors for the GPU and drives, etc...), and motherboards are a lot less tolerant of spikes and transients than the PS on the other side. Dealing with AC power isn't really that dangerous if you're careful.
- TheSpiceIsLife 6y agoEven high voltage and high amperage AC isn’t dangerous. So long as you’re not earthed https://imgur.com/gallery/B2c5FfD https://imgur.com/gallery/B2c5FfD
- dhosek 6y agoWe had an electrician of questionable licensing do some minor work for us (replacing some switches and outlets). I asked him to tell me when I should go down to the circuit breaker to turn off the electricity and he told me not to bother. He did all the work with hot current running through the wires. I stayed close enough to be able to tell if I needed to call 911 but no closer while he worked.
- mschuster91 6y agoIn Germany this is called "Arbeiten unter Spannung" and perfectly legal if qualified (https://de.wikipedia.org/wiki/Arbeiten_unter_Spannung https://de.wikipedia.org/wiki/Arbeiten_unter_Spannung).
- dhosek 6y agoThe electrician was Croatian and, I presume, learned his trade there. It still terrified me.
- 0xffff2 6y agoI've done a ton of electrical work for my own benefit over the years and I'm perfectly comfortable doing things like swapping switches with live wires. I've never once had a problem. The one and only time I've fucked up was when I cut a run of romex cable that I thought had been turned off. Lesson learned: electrical wiring is like a gun. Always treat it like it's on, and if you have to do something would be unsafe if the wiring is energized, make damn sure it's de-energized before proceeding. When you're working in that mindset already anyway, flipping the breaker for something as simple as swapping a switch/outlet hardly has any benefit.
- regularfry 6y agoCases can have "case open" switches that tell the machine to switch off. You can't necessarily tell beforehand.
- jrootabega 6y agoCase intrusion alarms (built in or Homebrew)
- mercora 6y agolinked below is an old advertisement/demo video of a similar device or maybe even the one you mentioned :) https://www.youtube.com/watch?v=-G8sEYCOv-o https://www.youtube.com/watch?v=-G8sEYCOv-o
- walrus01 6y agoVery similar, yes
- huhtenberg 6y agoIn a similar vein, there are USB gadgets that emulate a mouse that keeps on jiggling, to prevent the machine from locking out on user inactivity. However, there are anti-jigglers too that lock the machine when any new human input device is plugged in. http://codefromthe70s.org/antijiggler.aspx http://codefromthe70s.org/antijiggler.aspx
- kawsper 6y agoThat's interesting. You could have a list of known USB device IDs you trust, and if a newly plugged in USB device wasn't on that list you could lock or power down.
- ThePadawan 6y agoThat is a policy I heard to be used in already not-extremely-secure environments like software development at a bank (completely isolated from production environment). They didn't go so far as to cause alarms on unknown device ids, but devices would just not be mounted if they were not whitelisted.
- walrus01 6y agoAbout 13-14 years ago some parts of the US DoD resorted to hot glue gun filling all the usb ports on desktop PCs, except for the two ports required for the keyboard and mouse. This was during the windows XP era when it seemed there were an endless number of security problems related to usb devices, no matter how good the group policy and registry settings pushed via active directory membership were.
- swalsh 6y agoWhat does that solve though? I don't NEED a mouse to copy data.
- jrott 6y agoIt doesn’t solve for an outsider or malicious employee getting access to a machine. What it does solve for is an employee plugging in a compromised usb device on accident since they probably won’t unplug there keyboard or mouse for it.
- jlgaddis 6y agoSearch for "HotPlug" on YouTube.
- dghughes 6y agoI thought about HotPlug too. And the obligatory Seinfeld Frogger scene (become much less familiar to younger folks). HotPlug must only work in countries with terribly designed plug outlets like the US and Canada. Our NEMA 5-15 plugs are live when the plug's hot (electrons be here) and neutral (return to sender) blades are still visible. I don't think this device could work in the UK I'm not from there but I think their plugs can't be live with exposed plug blades. https://www.cru-inc.com/products/wiebetech/hotplug_field_kit_product/ https://www.cru-inc.com/products/wiebetech/hotplug_field_kit...
- Scoundreller 6y agoJust need to carefully expose the wiring in the cable itself then. Or yank out the socket and connect to the wires there before snipping and shipping. Unplugging just enough to expose the prongs is risky because the point where contact is lost will vary from receptacle to receptacle. Chances are things are plugged into a multi-plug hub anyway. European homes are especially lacking in sockets in my experience.
- bob1029 6y agoHow do they deal with the loss of network connectivity? I could pretty easily write a script that forces my machine to reboot and do all manner of other things if some sort of network change is detected.
- walrus01 6y agoI don't believe that specific product addresses it at all. Undoubtedly the persons operating the kits have put some thought into it, but given the myriad of possible LAN configurations and types of software deadmans switches, it must be a difficult problem to solve.
- numpad0 6y agoOr motion, inactivity, vibrations in the room, etc. But that’s for another product/specialist I guess?
- reaperducer 6y agoThere used to be an OS X program that would lock the computer if it detected motion. As long as a trusted Bluetooth device was paired, the computer was fine. But if the device left range and someone touched the computer, it locked. There was also one that would use the motion detector to try to detect if the device was falling, and park the hard drive heads before impact.
- CydeWeys 6y agoYou could, but what % of running servers actually have such safeguards in place? I'd say almost none of them.
- discordance 6y agoThe next Dread Pirates Roberts would be interested in this safeguard
- jimmaswell 6y agoI'd have thought plugging something into the outlet and unscrewing the outlet to take with you would be more convenient than carefully splicing wires just enough not to disconnect them. All the easier if it's on a power strip.
- Scoundreller 6y agoSometimes they are on different circuits.
- jaclaz 6y agoTechnically you don't need to touch the naked wire, you only need to remove (carefully) the outer insulation and have the two (still insulated) wires separated for a few centimeters. Then there are splitter clamps. The most common ones are used (low voltage) on cars and motorcycles, they look like these: https://www.mesconnettori.it/index.cfm/it/ricerca/?flbr=rubacorrente https://www.mesconnettori.it/index.cfm/it/ricerca/?flbr=ruba... But there are professional ones, suitable to 110 or 240 V example: https://www.techno.it/en/products/all/thb-370-a2a/ https://www.techno.it/en/products/all/thb-370-a2a/
- miles 6y agoHotPlug Field Kit https://www.cru-inc.com/products/wiebetech/hotplug_field_kit_product/ https://www.cru-inc.com/products/wiebetech/hotplug_field_kit... "With the CRU WiebeTech HotPlug you can transport a computer without shutting it down. "The HotPlug allows hot seizure and removal of computers from the field to anywhere else. The HotPlug's patented technology keeps power flowing to the computer while transferring the computer's power input from one A/C source (such as a wall outlet or power strip) to another (a portable UPS) and back again. "We created this product for our Government/Forensic customers, but it has IT uses as well. Need to move a server without powering it down? The HotPlug can do it. "It's great for digital forensic investigators and techs who can't risk losing access to data on a running computer. With many computers now employing full-disk encryption, shutting them down poses the risk of having to crack a password after moving the computer to a lab for analysis, which can greatly increase the time and expense of an investigation. When combined with a WiebeTech Mouse Jiggler, you also won't have to worry about the computer entering password-protected screensaver or sleep modes."
- Scoundreller 6y agoTime to geo-fence the servers with an external GPS antenna (often useful for time-sync). Or maybe FM signal strength locks?
- askvictor 6y agoWouldn't an accelerometer be a bit easier? Guess it can't hurt to have multiple defenses.
- Asooka 6y agoIf the police are seizing your PC (presumably following an investigation and a warrant) and you have put an accelerometer to shut it down (or unmount an encrypted volume) when moved in order to deny them access to the encrypted data, would this not count as tampering with evidence? If I were to do this, I would try and find a secondhand server that already has similar protection built in, so if anyone asks I could say "I did not even know it came with this feature".