> The reason is because they use "SMR", which severely hurts random-write performance. It hurts random-write performance after a threshold, when an on-disk sta
by Majromax 7y ago
> The reason is because they use "SMR", which severely hurts random-write performance.
It hurts random-write performance after a threshold, when an on-disk staging area becomes exhausted. For short bursts, the drive behaves well -- it probably would legitimately work in a RAID array if the array were initialized from a clean slate and not rebuilt.
> But this is yet another interesting edge case that RAID software doesn't handle and reacts by just blowing away your data.
It's not obvious how a RAID controller should "handle" this. The drives have no outward indication that they suffer from random write saturation. From the controller's perspective, the degraded performance looks very much like a drive failure.
- throwaway2048 7y agoA raid array that cant rebuild is near 100% worthless (outside of raid 0)
- kstrauser 7y agoBut if the reason it can't rebuild is that the drives are unfit for purpose, you can't really blame the controller.
- Wowfunhappy 7y agoWhich is why the manufacturer shouldn't have branded them as NAS drives!
- kstrauser 7y agoYou're preaching to the choir. SMR drives are absolutely not NAS-ready, and it's insulting for WD to pretend otherwise.
- magicalhippo 7y ago> SMR drives are absolutely not NAS-ready DM-SMR at the very least. If the RAID controller (hardware or software) is SMR-capable, then host-managed or host-aware can work. For example, ZFS with the recent support for separate metadata devices[1] seems to be close to what you'd need for it to become SMR-capable. [1]: https://github.com/openzfs/zfs/pull/5182 https://github.com/openzfs/zfs/pull/5182
- kstrauser 7y agoFair distinction.
- myself248 7y ago> the degraded performance looks very much like a drive failure. Sure, but given the choice between "During a rebuild, it looks like another drive isn't doing so well, so I should give up and trash the array" and "During a rebuild, it looks like another drive isn't doing so well, so I should notify the administrator and meanwhile try to maintain as much redundancy as I can" which is the sensible choice?
- imtringued 7y agoThere is no choice to be made. Once too many disks fail the entire array has to be taken offline and that's exactly what happens.
- labawi 7y agoDisks "failing" is the problem. If you treat drive state as binary (flawless / eject), you can easily eject too many drives for errors on different 0.000001% of data, crashing the array along with the data.