6 ms·
> "Exposure to CO2 and VOCs at levels found in conventional office buildings was associated with lower cognitive scores than those associated with levels of the
by WalterBright 7y ago
> "Exposure to CO2 and VOCs at levels found in conventional office buildings was associated with lower cognitive scores than those associated with levels of these compounds found in a Green building." – Allen et al 2016. The effect seems to kick in at around 1,000 ppm of CO2.
The last time this came up I bought a CO2 meter for my office. I was quite surprised how often it went over 1,000. Outside air runs around 450.
I increased the duty cycle of the house fan, and open a window when it reaches 800. Right now I'm at 505.
Buying the meter was a really good investment.
- popotamonga 7y agoWhere please? What model.
- en-us 7y agoI'm not the OP, but I use this one with similar results: https://www.amazon.com/gp/aw/d/B01FYWU2IS https://www.amazon.com/gp/aw/d/B01FYWU2IS One of these days I'm going to have to rig up something to start the house fan when the CO2 goes above 800 ppm and I think you'd need a different sensor with a realtime output port for something like that.
- bumby 7y agoIf you want a reference on setting this up to meet industry standards on demand controlled ventilation practices see ASHRAE 62.1 and 62.2 standards
- ip26 7y agoDirect feedback is cool, but a simple schedule is really easy & reliable. Even occupancy detection isn't all that critical- nobody wants to come home to a stuffy house, and most people's schedules are very predictable. These days IoT is so widespread that something like a $25 WeMo smart outlet is hard to beat. Hard wired is "best" but a million times more hassle and more expensive.
- WalterBright 7y agoCO2Meter AZ-0004 https://www.amazon.com/gp/product/B001PDGFR8/ https://www.amazon.com/gp/product/B001PDGFR8/
- jeffnappi 7y agoI own this one as well, it's supposed to be one of the more accurate models available for the price
- elitan 7y agoWhere did you get the information about this model being more accurate than other models in the same price range?
- jeffnappi 7y agoThis was the article that gave me that impression iirc - https://medium.com/@dhh/air-quality-matters-but-dont-trust-foobot-on-it-e2df4234a776 https://medium.com/@dhh/air-quality-matters-but-dont-trust-f...
- sxates 7y agoI did the same thing at my office and brought it into a conference room with 7 other people. We watched the CO2 climb to about 900 and then it started going down. Seems the climate control system is also tracking CO2 and it started pushing fresh air in when the level got too high. A nice surprise that we have systems managing this - I don't know how common that is in offices though.
- romwell 7y agoCould be a correlation with heat: seven people in a tiny room can generate enough heat so that the thermostat kicks in.
- fossuser 7y agoI think this is a common (maybe required?) thing in HVAC systems where they detect CO2 and turn on when it climbs too high.
- zebraflask 7y agoAnecdotal, but I used to work in an IT department where some areas had good, or at least tolerable, ventilation and some very clearly did not. The difference in moods and productivity between teams in each was distinct enough to notice, but, at the time, I don't think anyone would have thought of CO2 levels as a confounding issue.
- Psychlist 7y agoI have a slightly more capable one but the results are similarly motivating. Right now I'm more concerned with the particulate counts... if 27 is bad, does 120 worse and going outside into 700+ me dumberer? inside: https://www.uradmonitor.com/tools/dashboard-04/?open=82000090 https://www.uradmonitor.com/tools/dashboard-04/?open=8200009... outside: https://www.uradmonitor.com/tools/dashboard-04/?open=82000117 https://www.uradmonitor.com/tools/dashboard-04/?open=8200011... In the office at work is better: https://www.uradmonitor.com/tools/dashboard-04/?open=82000116 https://www.uradmonitor.com/tools/dashboard-04/?open=8200011... When I was living in Lakemba this prompted me to rig a HEPA filter outside and run my bedroom at positive pressure. That helped a lot. But I've had to move for work so now I'm renting a cardboard box (ok, technically it's "fibro" on piles with a leaky wooden floor. Outside ~= inside)
- davidwihl 7y agoWhat device did you use to capture all the data including radiation?
- Psychlist 7y agoClick the "home" link on those pages to go to the uradmonitor home page.
- kardos 7y agoFrom your indoor page, CO2 min is 375 ppm. How did you get that below the atmospheric value of ~410 ppm?
- Psychlist 7y agoI have no real idea, especially because the outside unit is about 10m away and shows ~700ppm. I will try swapping them to see whether it's a calibration issue, but right now the outside unit is at work with me so I can open it up and take photos.,
- amelius 7y agoCurious, did you notice the cognitive effect yourself?
- WalterBright 7y agoNo. But I do notice I think better when jogging - whether that is due to fresh air outside or increased blood flow, who knows. Probably both.
- amelius 7y agoPerhaps you could use one of those blood oxygen saturation meters to find out what is going on.
- amelius 7y agoPerhaps when we commit code, we should have a script that adds "this code was written at x ppm CO2" to the commit message :)
- WalterBright 7y agoI learned long ago to not even try to write code when I'm above a certain threshold of tiredness. I just have to tear it all out again after a night's sleep.
- blaser-waffle 7y ago"Written at BAC .04 / couple of pints, no smokes"
- pastor_elm 7y agoI see low CO2 spaces becoming the next big thing for the privileged classes as CO2 levels rise. Weworks of the future will be advertising this as a definite selling point. Mansions with scrubbers getting it down to 200ppm
- WalterBright 7y agoOpening a window works fine. I recall reading once that the health of poorer people was better one or two hundred years ago because poorer people ate cheap food - i.e. vegetables - rather than a meat-heavy diet.
- kaikai 7y agoOpening a window only works up until ambient CO2, which will continue to rise. A scrubbed interior atmosphere is already a selling point during fire season in the Bay Area.
- alexis_fr 7y agoSeriously, I’ve always thought people in Sydney compared to France were taller and healthier because they have more oxygen... Not only they are outdoors often, but they also have less stuffy buildings. Classrooms in France are the epitome of “stuffy”, and it’s frequent for me to leave a theater because there is 400 people and the vents are off. The usual reaction is to imply I’m sensitive ;)
- moultano 7y agoI put one in my son's bedroom and was blown away. He's 3, and calls me in to sleep with him sometimes. It's a small room, and we keep the doors closed so his sister doesn't wake him up and I was blown away by how high the CO2 got with both of us in there: https://www.reddit.com/r/dataisbeautiful/comments/cek4dm/co%E2%82%82_in_my_sons_bedroom_at_night/ https://www.reddit.com/r/dataisbeautiful/comments/cek4dm/co%...
- 9HZZRfNlpR 7y agoWhat did you use to measure? Unfortunately all the ones I've seen linked here are too expensive for someone like me who doesn't live in America. I wonder if there are cheap ones out there that maybe not so precise but at least measure something.
- jobigoud 7y agoReminded me of the videos by Kurtis Baute: "I sealed myself in a Jar". https://www.youtube.com/watch?v=PoKvPkwP4mM https://www.youtube.com/watch?v=PoKvPkwP4mM
- jonstewart 7y agoOne of the big trends in green/sustainable building is creating relatively air tight buildings in order to cut down on heating and cooling costs (see: Passiv Haus, Passive House, Pretty Good House). In order to do that, though, mechanical ventilation is needed. As a result, Heat-Recovery Ventilation & Enthalpy-Recovery Ventilation residential units can be installed for only $2k-$4K. Seems like a worthwhile investment (for when it’s not convenient or possible to open a window).
- ip26 7y agoThe other upside to sealing plus mechanical ventilation (instead of leaky-building ventilation) is that your building is always fresh. Leak-driven ventilation leads to a building that is drafty on windy days and stuffy on calm days.
- fyfy18 7y agoPlus if the leaks involve air circulating though insulation in the cavity or attic, whatever is in there will end up in your house air. That could be dust from construction, parts of the insulation material, or decomposing rodents.
- lstodd 7y agoUnless the system is of exceptionally poor design, air is never moved at enough speed to pick up dust. If it is, the whatever dust that gets picked up ends up in filters in the first week of operation.
- tekstar 7y agoExcept these heat exchangers have two filters that need cleaning very 3 months and most people never do it, so they don't really function properly.
- rypskar 7y agoIs the 3 months interval a regional thing, or based on the heat exchanger? Mine have 1 year intervals, and with a subscription for filters it is easy to remember to change the filters
- cylinder 7y agoBeen meaning to do this; do you have a link or recommended model?[EDIT: I see you already responded with the model below - https://www.amazon.com/gp/product/B001PDGFR8/ https://www.amazon.com/gp/product/B001PDGFR8/ ] I'm very sensitive to lack of oxygen in a room. Our office is old and some days they don't run the A/C if it's not hot enough outside, and I feel like I'm suffocating and my productivity suffers.
- gwern 7y agoPrevious discussions on HN debating the Allen result among others: https://news.ycombinator.com/item?id=14738010 https://news.ycombinator.com/item?id=14738010 https://news.ycombinator.com/item?id=21237875 https://news.ycombinator.com/item?id=21237875 https://news.ycombinator.com/item?id=18959796 https://news.ycombinator.com/item?id=18959796 https://news.ycombinator.com/item?id=19845029 https://news.ycombinator.com/item?id=19845029 https://news.ycombinator.com/item?id=14738010 https://news.ycombinator.com/item?id=14738010 http://lesswrong.com/r/discussion/lw/nk0/what_is_up_with_carbon_dioxide_and_cognition_an/ http://lesswrong.com/r/discussion/lw/nk0/what_is_up_with_car...
- ralphstodomingo 7y agoThanks for these links Gwern, down the rabbit hole I go. But how would you summarize the situation? Is it that there's not a definite study that proves the whole thing?
- UnbugMe 7y agoThose links, one per line: https://news.ycombinator.com/item?id=14738010 https://news.ycombinator.com/item?id=14738010 https://news.ycombinator.com/item?id=21237875 https://news.ycombinator.com/item?id=21237875 https://news.ycombinator.com/item?id=18959796 https://news.ycombinator.com/item?id=18959796 https://news.ycombinator.com/item?id=19845029 https://news.ycombinator.com/item?id=19845029 https://news.ycombinator.com/item?id=14738010 https://news.ycombinator.com/item?id=14738010 http://lesswrong.com/r/discussion/lw/nk0/what_is_up_with_carbon_dioxide_and_cognition_an/ http://lesswrong.com/r/discussion/lw/nk0/what_is_up_with_car...
- JohnBooty 7y agoIn the comments on that lesswrong post from a few years back, you raised a good question that is perhaps easily answered: it has the same issue as Kurzban's blood-glucose/willpower criticism: if the brain needs more oxygen than it's getting why doesn't one simply breath a little more? While sedentary during these sorts of tasks, you have far more breathing capacity than you should need Seems quite likely (or at least very possible) that we've outpaced evolution here, right? Prior to the industrial revolution, seems our bodies would never have needed to adapt to a rapid spike in environmental CO2 levels. Our brains are necessarily good at signaling the body when they need more oxygen; they're not necessarily good at realizing when they're dealing with other issues they're not adapted to react to. I believe there may be a common misunderstanding the relationship between CO2 levels and oxygen in one's body, at least as it was explained to me by doctors during my mom's struggles with COPD. Blood oxygen saturation levels and CO2 levels are not inversely correlated. One of the problems with late-stage COPD and reduced lung function is that while it's relatively easy to get a person's oxygen levels up (just administer oxygen!) they still suffer the effects of excess CO2 in the blood. A late stage COPD sufferer can have > 95% O2 saturation in their bloodstream and still suffer the other effects (including cognitive issues) that result from the excess CO2. (Apologies for responding you wrote four years ago)
- techiferous 7y agoAfter watching this Tom Scott video https://www.youtube.com/watch?v=1Nh_vxpycEA https://www.youtube.com/watch?v=1Nh_vxpycEA I bought this CO2 monitor: https://amazon.com/gp/product/B00MB93CK8 https://amazon.com/gp/product/B00MB93CK8 It worked quite well and showed that I don't have anything to worry about. Now I'm trying to pass it on to someone else. I'll be willing to sell it for half price if anyone is interested.
- deleted 7y ago[deleted]
- essem 7y agosent you an email!
- darkmighty 7y agoIf anyone is interested it seems you can find (more or less reliable) sensor modules for about $20, such as the MH-Z19, and read it from to an arduino or esp.
- initself 7y agoWhich meter did you buy?
- saberdancer 7y agoDoes anyone know of a cheap IoT type sensor for CO2? It can be any type, even RasberryPi or Arduino based. I'm not interested in sensors without connectivity options. About the levels, I'm working on an IoT project and I've seen data from a public school that has heating with radiators (so no real ventilation). One classroom with the sensor would routinely rise above 1000 ppm, with peaks over 3000ppm. Then you'd observe a sudden drop in CO2 level and temperature as they would open up a window. It's insane how high it can get especially if the building lacks proper ventilation.
- benjaminRRR 7y agoI bought this guy for the office - works well https://www.amazon.de/gp/product/B00TH3OW4Q https://www.amazon.de/gp/product/B00TH3OW4Q
- Youden 7y agoThere are a bunch of raw sensor components that you can connect to an Arduino or Pi. I ended up going with the Sensirion SCD30 but also tested options from Amphenol's Telaire line. Both are pretty easy to communicate with using an Arduino. I haven't tested an MH-Z19 but that's a popular cheap option.
- vixen99 7y agoOn the other hand, a paper on 'Effects of Exposure to Carbon Dioxide and Human Bioeffluents on Cognitive Performance' (2015) concludes that 'only exposures to bioeffluents when CO2 reached 3,000 ppm significantly affected performance of some cognitive tasks. Increased arousal level at this exposure can be used to explain the observed results.'. https://backend.orbit.dtu.dk/ws/portalfiles/portal/125818556/1_s2.0_S187770581502768X_main.pdf https://backend.orbit.dtu.dk/ws/portalfiles/portal/125818556...