I'm not a big fan of KV stores either, but I accept that they exist because there's an origin story for these things that makes a lot of sense. External storage
by hinkley 7y ago
I'm not a big fan of KV stores either, but I accept that they exist because there's an origin story for these things that makes a lot of sense. External storage of shared state fixes problems for shared-nothing and shared-everything programming environments.
In Java it gives teeth to the "write once, read many" pattern. By avoiding side effects you can scale your team larger. But it's a constant drain on resources to police this convention. There's always someone who thinks their reason to violate the rules is valid. Pushing the data out of process increases the cost of modifying data that should be read-only, and violations advertise loudly. You can't achieve it by obfuscation, intentional or otherwise.
Practically though, at the time KV stores were coming into existence, you could buy hardware with so much memory that Java couldn't keep up. They hit a GC wall that was causing serious problems. And running multiprocess was just anathema. If you push all of the long-lived objects out to the KV store not only does memory drop like a rock but what's left over is 'young' objects, and GC often optimizes for short-lived objects. In a way it becomes a self-fulfilling prophecy. By making in-process caching expensive they made it unwelcome.
In this same timeframe, latency on network cards became lower than latency to your drive controller. Reading something out of memory on another machine in the same data center was faster than getting it off of your own disk.
Meanwhile in an environment where all tasks are pretty isolated from each other, in-process caching is ungainly. Either you suffer with a low hit ratio, you do some sort of bizarre traffic shaping, or you do caching at the ingress point so you don't make the requests at all. But that informs your engineering priorities to such an extent most people don't like. But I see it as one of those "uncomfortable" things that Continuous Delivery advises you to face head-on. Cache invalidation is hard, yes. Wear a helmet.
So the shared-nothing people also liked these tools, which means you have two groups that probably normally wouldn't talk to each other pulling for the same team.
- dev_dull 7y ago> In this same timeframe, latency on network cards became lower than latency to your drive controller. Reading something out of memory on another machine in the same data center was faster than getting it off of your own disk. Was this before SSDs?
- wtallis 7y agoThat era started before SSDs went mainstream, and it's not over. RDMA has much lower latency than NAND flash, which is why NVMe over Fabrics is getting so popular. Fetching data from a locally attached SSD isn't much faster than fetching it from a different server in the same rack.
- Dylan16807 7y agoTo put some numbers on that, typical TLC flash is around 50 microseconds to access, optane and specialized SLC flash are under 10, and an infiniband connection between machines is around 1 to 1.5 microseconds.