As far as I know, there's no advantages between 50 and 60 hz. I suspect the difference was political, but maybe someone else knows more about it than me? As fa
by gwbas1c 7y ago
As far as I know, there's no advantages between 50 and 60 hz. I suspect the difference was political, but maybe someone else knows more about it than me?
As far as voltage is concerned, there's a very good reason why most of the world uses about 240 volts for "normal" outlets. The American 120 volt system is fine for things like TVs, clocks, computers, ect, but it's horrible for things like space heaters and electric cars. When I see videos from countries with higher voltages, I see much larger space heaters than we can handle on our outlets. Also, electric cars charge twice as fast from an ordinary European outlet than a normal American outlet.
The cost of copper even starts to make high voltages look better. In my house I have extremely thick (expensive) wires running to my heat pump, but if I had higher voltages these wires could be smaller (and cheaper.)
- klodolph 7y agoTransformers for 60 Hz are smaller and cheaper than transformers for 50 Hz. In general this continues to be true as you increase the frequency, although there are some effects that you need to compensate for as the frequency increases. Your phone charger might have a transformer operating at something like 1 MHz. As a result, it can be made very, very small.
- alex_young 7y agoThere's also a very nice property of 60 hz: Your clocks don't lose their time very often since they have a very predictable source of truth built right in.
- AstralStorm 7y agoRelying on network frequency as being accurate to any degree is madness. It's not even useful for any correction. Even the most basic RC oscillator outperforms it by orders of magnitude.
- garaetjjte 7y agoAt least for Europe, it is accurate. Frequency is actively changed to maintain 50Hz in long term: https://www.mainsfrequency.com/gridtime.php https://www.mainsfrequency.com/gridtime.php
- sp332 7y ago> madness Yeah but that doesn't mean people don't do it. https://arstechnica.com/tech-policy/2018/04/european-grid-dispute-resolved-lost-6-minutes-returned-to-oven-clocks/ https://arstechnica.com/tech-policy/2018/04/european-grid-di...
- namibj 7y agoIn Europe the grid phase is supposed to be pegged to UTC. In recent times (1~2y) we have some fluctuations because some south east european countries have some disputes about paying vs. being cut-off, which creates an energy imbalance in the network that's not trivially corrected for like normal small leakage or rounding errors. It is usually very stable over long time periods, considering the rarity of power outages lasting more than a few seconds. Most are just factions of a second, when the 10/30kV network (underground in cities) needs to be switched to a different upstream transformer. It's basically a circuit breaker with automatic failover. (Multi-second outages are explained by emergency load shedding, followed by re-connecting residential consumers and not the industrial ones. Necessary after long-distance transmission lines fail their redundancy and cause regions to be partially cut-off and then it's load-shedding vs. cascading failures.)
- klodolph 7y agoIn the US the grid used to guarantee 5184000 per day with only short-term fluctuations (standard WEQ-006, the exact deviation allowed depends on which grid you are talking about). This was used by e.g. cheap clocks in coffee makers, but also by synchronous motors used by telescopes to align the telescope with the stars. More recently, with our larger power grid, it is more efficient to deviate from 60 Hz. I do not understand the exact reasons, but for some reason the 5184000 cycle/day guarantee turns out to come with some cost when you have a hundred gigawatts of power spread across a thousand miles. There have been two petitions in North America to remove TEC and allow synchronous clocks to accumulate error, I believe this is going forward but not yet implemented. See the section "Time Error Correction": https://en.wikipedia.org/wiki/Utility_frequency https://en.wikipedia.org/wiki/Utility_frequency See the section "Accuracy": https://en.wikipedia.org/wiki/Electric_clock https://en.wikipedia.org/wiki/Electric_clock
- sp332 7y agoI don't see a difference there between 60 Hz and 50 Hz. One has 1/60 of a second between cycles and the other has 1/50 so as long as you can count to 50 instead of 60 it's the same, right?
- mikestew 7y agoWhich one can you use to make the second hand tick accurately without having to count at all?
- sp332 7y agoYour second hand ticks 60 times every second?
- alex_young 7y agoBase 12. Think gears turning gears turning gears.
- Dylan16807 7y agoA gear reduction of 2x5x5 is just as easy as a gear reduction of 3x4x5.
- zokier 7y agoHow is that a property of 60Hz?
- blattimwind 7y agoIt isn't.
- jdietrich 7y agoAircraft use 400Hz AC for exactly this reason.
- throw0101a 7y ago> As far as voltage is concerned, there's a very good reason why most of the world uses about 240 volts for "normal" outlets. If North America would ever decide to start using 240V for appliances (through a transition period), what style of plug should be used? UK-style (Type G)? Europlug? Other? * https://www.worldstandards.eu/electricity/plugs-and-sockets/ https://www.worldstandards.eu/electricity/plugs-and-sockets/
- zokier 7y agoSchuko is pretty solid choice, and conveniently already being used by large part of Europe. If polarization is must for some reason and schuko feels too bulky then I guess IEC 60906-1 is as good choice as any.
- throw0101a 7y agoWhy not have polarization if you can get it?
- zokier 7y agoHaving non-polarized sockets forces devices to be polarization agnostic, which could be safer... Not that I actually know anything about electric safety engineering. And of course there is the ergonomic aspect that allows you to insert the plug in any orientation, compare to usb-c
- gwbas1c 7y agoSchuko is unnecessarily large. I've always wanted an international standard with notches that indicate the voltage and frequency. A device that accepts all voltages and frequencies will accept any notch, a more selective device would block a notch for the frequency / voltage it can't handle. (And the plug would need to fully cover the pins once they have current. That's the big problem with the NEMA and Europlugs, the pins are still exposed when they're live.)
- zokier 7y ago