3 ms·
A better example would be the ceramic bearing fiasco that NetApp experienced with Seagate. Seagate had switched to a floating ceramic bearing on one family of t
by ChuckMcM 8y ago
A better example would be the ceramic bearing fiasco that NetApp experienced with Seagate. Seagate had switched to a floating ceramic bearing on one family of their fiber channel drives. In those drives one or more of the bearings would shatter and start spreading ceramic dust across the disk surface. This happened between 3 and 4 years of run time and the disk would rapidly fail after that happened. People that bought a filer with several hundred drives started seeing large numbers fail suddenly. Up to the point they failed, not any indication. But it was run time hours related and thus correlated to all drives that started running at the same time. If you had put those drives in different data centers on different racks on different servers it wouldn't have mattered if you started 20 at the same time to be your 'tome', when they started failing it was possible to lose them all in a week.
- tlb 8y agoThere was also a failure mode in Seagate drives where the bearing increased in stiction. As long as it was spinning, there was no problem. But if you spun it down, it might not spin up again. If you had a group of disks powered up for a long time, many could fail together at the next power cycle. A chaos monkey that randomly powers down disks one at a time can prevent this.
- deleted 8y ago[deleted]
- Dylan16807 8y agoThough that sounds like a fixable failure mode, so it's more annoyance than tragedy.
- tinus_hn 8y agoYou can tell from the reports they put out that Backblaze doesn’t put all their eggs in one basket, they use different brands and drive types.