3 ms·
Is it really required to actually read currents to achieve the power measurement? do meters in individual buildings not have interval-flashing LED's for power c
by alkonaut 9y ago
Is it really required to actually read currents to achieve the power measurement? do meters in individual buildings not have interval-flashing LED's for power consumption in the US (I'm assuming the target market is the US)?
A flashing LED is neat because you can then use a very simple-to-install adhesive photodiode to count the flashes and radio the results back to some reader (e.g. 1000 impulses per kWh). Doesn't require an electrician because you never actually tamper with the meter, unless you want to leech a tiny bit of power to your transmitter.
The normal connection here is a big outdoor box for the incoming line, with 3 main fuses, one for each phase. Typically 3x25A @ 230V for a detached home (Max ~17kW). This is where you want to read the power consumption. Inside the house there is a box with 3 DIN rails (1 per phase) with switch type fuses. With 3 phases it's a lot harder to read the power consumption there than it is at the outside main fuse box (which is unfortunate, because it's a lot more convenient to mount a meter indoors and near a wall socket, than outside inside a thick steel box without easily accessible power for your power meter+radio).
- emilburzo 9y agoWould nobody bat an eye if you had an electronic device attached to the meter? (especially the guy that comes and does the meter reading)
- alkonaut 9y agoNo, the meter is sealed, which is the benefit of this type of arrangement. The meter just sits attached to the meter on the outside, so it's obvious that nothing is tampered with. Many power companies even sell their own (branded) kits that does this. It's also very rare to have someone come read the meter. Like all other parts of society anything that can be automated at almost any cost has been already. I have had no one read water or power meters for many years.
- emilburzo 9y ago> I have had no one read water or power meters for many years. Ah, that makes more sense now :) Over here we still have people that come to read the meters every 3 months.
- pbhjpbhj 9y agoIn the UK they use estimated readings, primarily it seems as a way to borrow a pretty large amount from their customers - they appear to "estimate" at 20% above actual rates. Evil, but pretty clever.