Check the actual papers.[1][2] For single-phase meters, which covers most residential uses, this is a non-problem: "No deviation beyond the specification
by Animats 10y ago
Check the actual papers.[1][2] For single-phase meters, which covers most residential uses, this is a non-problem: "No deviation beyond the specification could be observed; no influence of interference due to interfering or distorted voltage, and no influence caused by interfering currents were observed." All the problems were seen with 3-phase meters, usually found only in industrial and commercial environments.
Figure 3 of [1] is puzzling. They claim to be testing a 3-phase meter, but the circuit shown is single-phase. Are they testing 3-phase meters with only one phase connected? That's way out of balance; 3-phase systems normally have at least roughly equal loads on each phase. While a 3-phase meter with an wildly asymmetrical load ought to measure accurately, that's not a normal condition.
[1] http://doc.utwente.nl/102016/1/Runaway_energy_Meters.pdf http://doc.utwente.nl/102016/1/Runaway_energy_Meters.pdf
[2] http://ieeexplore.ieee.org/document/7866234/ http://ieeexplore.ieee.org/document/7866234/
- Toomas 10y agoI'm no electrician but I'm sure 3-phase meters are a norm in Estonia. You would usually have devices with high power requirement like electric water heaters and ovens connected to separate phases. And they are often sitting idle as well.
- snom380 10y agoSame in Norway. Almost all new installations have 3-phase.
- semi-extrinsic 10y agoNorway is a different case from most of the rest of the world, we run what's called an IT network earthing system where there is no neutral lead. Everything is connected between two phases getting 240v, and the earth wire is tapped from an actual metal rod dug into the earth. This setup is pretty much a mess, and can wreak havoc on laboratory setups, so e.g. at universities all the lab rooms are laid out with TN (the standard everyone else uses). This means you can mess stuff up in the lab by running an extension cord from the adjacent non-lab room (e.g. get large ground voltage differences, all sorts of wanky stuff).
- sathackr 10y agoIn the US, devices with high power requirements are generally connected "between" phases -- the phase-to-neutral voltage is(depending on your transformer configuration) generally 120v, with some configurations generating 208v from 1 of the 3 phases to neutral. Phase-to-phase voltage is generally 220-240v. Loads that span all 3 phases are generally motor loads that will benefit from the rotating magnetic field that 3-phase service provides -- such as pumps and compressors. 3 phase power to residential is rare in the US.
- sbierwagen 10y agoYou're confusing two subtly different things. Residential power in North America is usually delivered as "split phase", +120V, neutral, and -120V. (180 degrees out of phase: https://www.youtube.com/watch?v=vOh2OSJ44eE https://www.youtube.com/watch?v=vOh2OSJ44eE) The voltage across the two hot conductors is 240V, which is used for big stuff. You get it by tapping a transformer in the middle of a coil: https://en.wikipedia.org/wiki/Split-phase_electric_power https://en.wikipedia.org/wiki/Split-phase_electric_power Three phase power has three hot conductors, 120 degrees out of phase to each other. In the US it can be delivered at a bunch of different voltages, depending on what transformer the customer installs, but generally I worked with 277/480. (277V hot to neutral, 480V hot to hot. Generally all commercial lighting runs on 277V.) And to be specific, three phase is primarily useful because motors that use it are self-starting, you don't need to capacitor-and-switch arrangement single phase motors use, which frequently break. Less important now that most big motors use VFDs. Also, supposedly due to some frequency voodoo you don't need to use as much cable when running three phrase transmission cable.
- sathackr 10y agoThanks for the clarification and much more detailed explanation. I was aware of the split-phase nuance and have been hit by 277 a couple of not-so-fun times. As to the benefit to motors, it was my understanding that using split-phase or a single phase and a capacitor creates a less-than-optimal magnetic field which results in more noise/vibration and wear on the motor as opposed to 3 phase.
- 10y ago
- grk 10y agoMost new apartment buildings in Poland have 3 phases connected to all apartments. Since there's municipal central heating, there's no point in connecting natural gas to those buildings, so you're forced to use induction stovetops. And those are much more efficient with 3 phases.
- Dylan16807 10y agoInduction stovetop spots are usually one big coil fed at a high frequency, right? How do the phases of the power supply matter?
- swinglock 10y agoIn Europe 3-phase is the most common.
- baha_man 10y agoSource?
- bjelkeman-again 10y agohttp://electrical-engineering-portal.com/north-american-versus-european-distribution-systems http://electrical-engineering-portal.com/north-american-vers... > Most European transformers are three-phase and on the order of 300 to 1000 kVA, much larger than typical North American 25- or 50-kVA single-phase units.
- bonzini 10y agoThat's the network transformers. Homes usually get single-phase 230V, while larger users get three-phase 400V.
- the_mitsuhiko 10y agoThat is absolutely not the case where I live (Austria). You get multiple phases into your home, at the very least to garage and kitchen.
- MrBuddyCasino 10y agoElectric stoves in Germany are usually hooked up to a special 3 phase wire in the kitchen, but thats the only exception in can think of, at least for apartments.
- bonzini 10y agoOh, here in Italy we have only 3 kW power to each apartment, so gas stoves are prevalent.
- 10y ago
- speleding 10y agoThis is a Dutch study. 3-phase is the norm here.
- davedx 10y agoHas this been covered before in the Dutch news, or is this new? (I think I have seen concerns about privacy and smartmeters here...)
- throwawayish 10y agoIn most parts of Europe 3-phase is the standard. Neither high-leg delta nor split phase have significant deployment outside North America. That being said, in household use the per-household balancing between the phases is usually very poor (e.g. all lightning on one phase). Overall the balancing turns out ok across the grid, but the meter doesn't see that. So this is a very relevant condition for household meters.
- Animats 10y agoAh. That's helpful. US utility residential practice, for those outside the US, is that pole transformers take in 3 phase at a few KV, at 60Hz, and output 120/240 VAC single phase with a shared neutral. That's what most houses get, supplied over 3 wires, with a 3-wire single phase meter. Pole-mounted transformers usually serve about 7 houses or so. Even in apartment buildings, each apartment has its own meter, almost always single phase.
- redrainbows 10y agoI'm interested in what area the overhead lines are only 1.1 kV. From what I have seen the high-side voltages are much higher, in the range of 7 kV or 14.4 kV line to ground. Also, most overhead transformers I have seen are entirely single phase. Often you will see a bank of 3 single-phase transformers if a customer requires 3 phase service. Larger customers are connected to a pad-mounted 3-phase transformer connected to the primary overhead service through an underground dip from the pole.
- hydrogen18 10y agoYou can't "take in 3 phase and output single phase". That's not how a transformer works. It'd be amazing if it did, as in Nobel Prize winning. In the US most homes are just tapped to 1 phase, if there are 3 on the pole.
- gfisher 10y agoYeah, you are right. I think what they were trying to say is that the transformers are fed on the high side by one of three phases (as is typical), and that the residential step-down is a split phase 120/240.