Diesel generators at Hospitals and diesel motors running pumps for fire suppression systems are normally set up to keep running closer to the line of risking damage to the generator and engine.
212.
▲
by
generatorguy
7y ago
Not every substation but definitely the system is protected against over and under frequency and voltage so that loads can’t be fed 45 Hz for a minute.
213.
▲
by
generatorguy
7y ago
It is a perfectly good signal to increase production.
214.
▲
by
generatorguy
7y ago
If 200 MW of generation trips instantly, which is typical when electrical equipment fails, you need 200 MW to replace it in the next few seconds, and then additional generation to bring the frequency back to Nominal. So far the largest batt
215.
▲
by
generatorguy
7y ago
It could well be true, This has happened many times
216.
▲
by
generatorguy
7y ago
When the frequency is nosediving and below some threshold it is a good sign that you want to switch to your back up power immediately. Even if there isn’t ultimately a cut, it is bad quality power and a sign of system instability
217.
▲
by
generatorguy
7y ago
the generator in the wind turbine is not generating at 66 kV. There is a transformer in the base of the turbine to step the voltage up to 66 kV. A 10 MW generator is typically at 6.9 kV, although could be up to 13.8 kV.
218.
▲
by
generatorguy
7y ago
Qiqqa? Although that’s not a CRM but it does metadata, tagging, and PDFs. Maybe it will work for you.
219.
▲
by
generatorguy
7y ago
i'm a former nortel employee. so sad to see people lose their houses and pensions due to chinese theft. The hacking wasn't even publicized as a warning that other companies could heed - get your security in order, be careful with
220.
▲
by
generatorguy
7y ago
luxury vehicle tax, empty property tax, the governments are starting to catch on
221.
▲
by
generatorguy
7y ago
I am a huge fan of knobs I can feel without looking to see if I got the right part of the smooth glass surface. “The elevated center console stretches down from the horizontal central screen to two air vents that are not the mechanically op
222.
▲
by
generatorguy
7y ago
The grid was built and operated on n minus 1 redundancy. Any single transmission line or substation transformer can fail and there should not be an outage. But if the other transformer in the same substation fails then you are in the dark.