No, you have to connect to an existing ground after checking its resistance or dig a new one. When digging the holes for new telco FTTC boxes replacing passive
by mschuster91 12y ago
No, you have to connect to an existing ground after checking its resistance or dig a new one.
When digging the holes for new telco FTTC boxes replacing passive-only boxes, we have to measure the quality of the existing ground, usually done with either 5-10m of 2cm wide, 3mm thick flat steel about 30cm belowground, or with a steel pole rammed ~3m into the earth directly next to the old box.
Usually the flat-steel is corroded and not usable any more (because the earth simply dries out), while the 3m poles are still good enough to use them.
In case the "old ground" is unusable, we tear it out (shit, that can involve LOTS of digging) and place a 1x0.5m steel plate at 50cm belowground, so that the bottom border is at 1.00m.
In the case of building a new grounder in an urban environment, I'd choose ramming a pole. It's easier, especially in areas with loads of wires and pipework - the downside is you have to rely on sometimes decades-old plans which can be off as much as two meters, and ramming a steel pole is enough to rupture a water or, worse, a gas pipe.