I'm genuinely curious whether new homes will start wiring lighting for DC to accommodate all these new LED bulbs? I just don't have a good sense whether its mor
by seanalltogether 12y ago
I'm genuinely curious whether new homes will start wiring lighting for DC to accommodate all these new LED bulbs? I just don't have a good sense whether its more efficient to transform AC to DC at a central hub in the home to distribute to all rooms, or more efficient to do it at the bulb itself.
- stephen_g 12y agoLine losses through the cables are usually a killer with really low voltage DC (like 5V or 12V), so I think that AC would be more efficient there. But some datacentres are using 48V DC now and then just piping that through a switching regulators in the servers instead of going from AC to DC. That could be workable.
- teh_klev 12y ago48V DC has been in multi-client data centres (Telehouse, TeleCity etc) for years. It's a standard voltage in telecoms kit. The data centre I was involved in building out back in 1999 got this as standard.
- ghostly_s 12y agoThe Emerge Alliance[1] is an industry group that has been working on this issue, though they've started with a spec for datacenters (as stephen_g alludes to). I think the consensus is that it is definitely more efficient to convert to DC at a single point, but one located as physically close to the loads as is practical, because of the line losses mentioned. Definitely something that will make sense for commercial buildings/campuses and multi-unit residential, and single family homes are not too far behind, I think. I can picture homes sometime soon just being wired for AC in the kitchen/garage/utility rooms with a LV DC grid elsewhere. The lower safety requirements for low-voltage really open up possibilities for system design and integration in the built environment. http://www.emergealliance.org/About/Vision.aspx http://www.emergealliance.org/About/Vision.aspx
- webignition 12y agoInterestingly, I'm looking to do exactly this in a new home (new to me, not newly constructed). I'll soon be moving to a park home (a relatively-permanent mobile home) that is in need of a fair amount of renovation. I'll be running all lighting, computers and the TV off 12v DV circuits powered by bank of vehicle batteries and where the batteries are charged from 12v solar panels.
- crististm 12y agoHave you considered cabling loses? There is a reason power lines use very high voltages.
- webignition 12y agoI've considered voltage drop over cable length only in as far as I'm aware that it occurs. I haven't tested the level of voltage drop. I currently use 12v circuits in my camper van and haven't experienced any significant drop over cables about 3m in length. LED-based lighting and a 12v fridge operate as expected and the voltage at the point the power reaches these devices is very close to the voltage over the battery supplying the current. I previously used 12v circuits in a narrowboat I used to own and didn't experience any drop over cables about 20m in length. This used halogen-based lighting and again the voltage at a lamp was very close to the voltage over the battery.
- zAy0LfpBZLC8mAC 12y agoJust to be sure: You are aware that you have to measure the voltage drop under load? Even with rather thick wires, 20m should give you some noticable voltage drop with any non-minimal load.
- ZoFreX 12y agoConverting voltages is trivial with AC, how do you handle devices that require something other than 12v (lots of phones want 5, lots of laptops want 18) with a DC system?