I used to be a server monkey long long ago, and played with the mockups of these servers that were set up at FB HQ. One thing to realize is they are heavy. Load
by aristus 12y ago
I used to be a server monkey long long ago, and played with the mockups of these servers that were set up at FB HQ. One thing to realize is they are heavy. Loaded with hard drives, one of these servers is roughly the size, shape and weight of a long 120mm mortar shell.
Easier to rack than the Dells of yesteryear, sure. But there can be up to 120 of these bad boys in a single standard rack, which means 60 of them have to be lifted above waist height during rack and stack. That is pretty strenuous, and technically you should use a moving lift and / or a lifting partner. Especially when you're talking about hundreds or thousands of racks.
Thinking outside the box and keeping the poor floor staff in mind, I've always wondered why we don't build little catwalks or half-height rack units, or even moving racks, like a dry cleaner's.
- wmf 12y agoDo they rack it with the drives or do they rack it empty and then install the drives?
- aristus 12y agoWith the drives. They really are little torpedoes.
- ControlledBurn 12y agoFor the server nodes that have storage in the sled, that's true, but with the JBODs they generally rack the the sled first and then add each drive.
- ianamartin 12y agoI don't see anything in this article that sounds like throwing out the rulebook. It sounds a lot like throwing out a few stupid rules. But not the whole book.
- forgottenpass 12y agoOf course it sucks, It's techcrunch, they can't actually write about tech. A bunch of vaguely clued in non-techies writing about tech companies for AOL don't target an audience that wants to hear about server hardware. They want to hear about how great (innovative, rule-breaking, etc...) facebook is. If server hardware is the vehicle for that story, so be it. This article is "company finds business value in customizing critical component instead of using COTS." And that's only interesting to people who understand the components. So they represent it poorly, but only a little bit, not badly enough to merit the weight we typically associate with the word "misrepresentation".
- hawkice 12y ago[Of course, but here is a little story] I recently heard of a legal principle having to do with what they termed "overbroad" interpretation. The idea is, if there is a law in the United States that could be used to violate the constitution, the whole law gets struck down -- this is often limited to e.g. a subsection. But notably, it doesn't change the law to be the same except in cases where it violates the constitution, it just implodes the law. There's something to be said about the principle of throwing away any system or subsystem that doesn't get the job done, and not just forking and patching it.
- jedberg 12y agoI used to do rack and stack in the eBay datacenter. We actually had double height racks (84U). I always wondered the same -- wouldn't it be easier to build a catwalk instead of having a bunch of ladders and lifts around that required two people?
- delluminatus 12y agoThis comment reminds me of my time as a sysadmin in college. I had to rack a lot of 1U and 2U servers (the Dells of yesteryear referred to) and they are EXTREMELY heavy. Racking them was tricky because you had to put together the rack mount yourself and then get it all lined up while you're holding this 100+ lb thing (which is awkwardly too long and wide to handle easily) at chest height and sliding it into the rails in the cabinet. One day they let me take a decommissioned PowerEdge server back to my dorm room. It was old, but it still had something like 16 cores, 64 GB RAM, and 2 hard drives. As a college student with no money I thought this was pretty cool. Carrying that thing five blocks to my dorm room was one of the hardest damn things I've ever done, and in the end it was too loud to use. Moral of the story: Rack-mount servers are not designed to coexist with humans.
- judgardner 12y agoServer lifts are pretty common kit in most colocations. http://www.material-lifts.com/client_images/catalog19960/pages/images/ServerLIFT-SL-1000X.jpg http://www.material-lifts.com/client_images/catalog19960/pag...
- peterwwillis 12y agoBarring those (and the space to fit it between the racks), you could attach tracks on the ceiling and use a moving chain & pulley to move them around with just one person. Granted, with double racks you'd still need a ladder to attach the chain.
- papercruncher 12y ago[unrelated] As someone who used to rack a lot of 120mm mortar shells, I empathize