Stirling (and other thermal-cycle engines) are about 30-35% in converting heat energy to useful work. In this case electricity. So dividing 10 kW by 30% will
by dredmorbius 12y ago
Stirling (and other thermal-cycle engines) are about 30-35% in converting heat energy to useful work. In this case electricity. So dividing 10 kW by 30% will give you the rough energy input. Casting that in therms/hr. (usual natural gas billing unit in the US is therms), it's about 1.14. Residential price is on the order of around $0.80 - $1.50/therm, so you're looking at about $25/day for 10 kW of continuous power. Which isn't far from what you'd be paying for electricity: $21 - 29 at $0.09 - $0.12 per kWh.
In terms of volume, 1 ft^3 is about 1025 btu, a therm is 10,000 btu, so you're looking at 97.5, let's call it 100 ft^3 of natural gas consumption per day.
As for running a Stirling engine on solar energy, or another heat source, yes, you could do that. Again, you need 33 kW of input power, which means a 33m^3 collecter surface -- that's 5.8m on a side, or 19 feet.
Because the Stirling's hot end is a point, you'd need tracking systems or a working fluid to deliver heat to it from your mirrors.
Incidentally, you can answer a lot of these questions using GNU units, written by Adrian Mariano. The great thing about it is conversion between different units and relationships, e.g., energy per hour per unit area. I find it invaluable in looking at energy, renewable, and related issues.