3 ms·
GAHHH. They messed up the units! The stated numbers (4 MPa for imperfect graphene) are wrong! They are meant to be fracture toughness (which is measured in Pa/m
by icegreentea 12y ago
GAHHH. They messed up the units! The stated numbers (4 MPa for imperfect graphene) are wrong! They are meant to be fracture toughness (which is measured in Pa/m^0.5), not just Pa. The paper is at [0]
Table 1 is where you want to look at. It places the fracture stress of pre-cracked graphene in the 1-10 GPa range(which should be compard to the stated 100 GPa for perfect graphene).
I don't have the full materials properties of graphene with me, and I'm not a materials guy, so I may have done something wrong above (so please correct me), but I'm fairly certain that at a minimum, the article messed up the units.
[0] http://www-old.me.gatech.edu/zhugroup/paper/NC14.pdf http://www-old.me.gatech.edu/zhugroup/paper/NC14.pdf
EDIT: replaced the link to a copy of the paper hosted by the author from the original nature (paywalled) link.
EDIT2: some changes after actually reading the paper instead of going off the abstract and supplied figures.