If I read it right, the movement is absorbed by shock absorbers that need to be installed for earthquake protection anyways. You just need to make sure that the
by mpyne 13y ago
If I read it right, the movement is absorbed by shock absorbers that need to be installed for earthquake protection anyways. You just need to make sure that the segment between the lateral movement/shock absorbers are sized such that the differential thermal expansion doesn't violate the deflection requirements.
- nickff 13y agoThe paper describes having a telescoping section on each end to accommodate thermal expansion, but the previous commenter is stating that it is likely this telescoping method will not be sufficient, as the variation in length of the structure will cause significant bending of the pylons themselves. Between the ends, there is no mechanism to allow for thermal expansion, which will either cause massive axial stress on the steel tube, bending of the pylons, or both. The shock absobers will not have sufficient travel to address this, (100s of meters); axial bearings on the tube may be required.
- tlb 13y agoEach 30M long tube expands 15mm over 40C of temperature change. You could imagine a 15mm expansion joint at each connection, which is roughly what oil/gas pipelines do, but the paper explicitly says tubes will be welded together for straightness.