3 ms·
From the spec: • External interface is multiple 10-15 Gbps SerDes interface, each with 16 full duplex lanes. (The 320GB number comes with 8 10Gbps links, the 4
by jws 14y ago
From the spec:
• External interface is multiple 10-15 Gbps SerDes interface, each with 16 full duplex lanes. (The 320GB number comes with 8 10Gbps links, the 4 link device is 240GB/s (higher clock rate))
• Internal ECC for memory, packet based interface with CRC and retry.
• Built in self test, there can be spare resources which allow it to replace failed sections.
Envision a city on a grid filled with sky scrapers. The ground floor of each skyscraper is the logic, called a "vault controller", each floor above is DRAM storage. The city is constructed by laminating chips, one for each layer, and the sky scrapers form their connections vertically through the chips.
There is a switching fabric that connects N serial links to M vault controllers.
• 16 vaults in the 4 link version, 4GB. 32 vaults in the 8 link version, 8GB.
• A single vault controller can be servicing many serial links simultaneously. It can prioritize. Within a single link, requests will always happen in order.
• There is a router system which allows up to 8 cubes to be on the same host link to increase storage per host link. Link length is limited and power demands are higher for longer links. I think the router will allow shorter links to be used, especially in multiple cube modules.
• Atomic bit write and atomic add transactions. New options for the lock free algorithm folk.
• 31mm^2 BGA. 4mm tall. For the 4 link device. About 900 pins. About half are grounds, 1/4 of the remainder are powers, the rest signals.
• 7 different power supplies at 4 different voltages required. Get to work board designers!
• READs and WRITEs are from 16 to 128 bytes wide.
• 4 link device can have up to 4GB, 8 link can have up to 8GB. (This seems small to me, but I suppose it comes down to storage/bandwidth balancing, and you can have 8 devices on the same link.) Oh, they see the problem too. They are considering using the currently ignored lower order bits of blocks to expand the addressing, and there are two bits reserved just above the address. Quick, someone get the time machine, take them to visit the IDE disk block addressing planners.
• The refresh logic checks ECC and rewrites if a soft error is found. Take that cosmic rays!