3 ms·
Another point, not mentioned in the article, is that you can't approach an MRI unit, unless you want to see the magnet rip out of your finger and ballistically
by pygy_ 14y ago
Another point, not mentioned in the article, is that you can't approach an MRI unit, unless you want to see the magnet rip out of your finger and ballistically destroy stuff on its way to the 1.5+ Tesla superconductive monster bathing in liquid helium.
/dramatic exaggeration.
Seriously, it can be very problematic, though. See http://www.simplyphysics.com/flying_objects.html http://www.simplyphysics.com/flying_objects.html
- iamdann 14y agoYup, just like people with cheap "prison" tattoos.
- Nogwater 14y agoNot according to Mythbusters: http://dsc.discovery.com/tv-shows/mythbusters/mythbusters-database/mri-machines-and-tattoos.htm http://dsc.discovery.com/tv-shows/mythbusters/mythbusters-da...
- iamdann 14y agoAdditionally, people with magnet implants have successfully had MRIs, too. http://stevehaworth.com/main/?page_id=871 http://stevehaworth.com/main/?page_id=871
- rtkwe 14y agoDidn't know they were always or mostly energized. I thought they were only powered during an actual MRI scan.
- fossuser 14y agoThey're super conductors so shutting them off involves draining all the liquid helium and nitrogen which is very expensive.
- sp332 14y agoWell you can have a superconductor with no current running through it. Just charge the electromagnet with current during the scan, then bleed it off gradually when you're done. No need to turn off the superconductivity to power down the magnetism.
- refurb 14y agoMRI magnets are a pain to setup. It's not an easy task. I can remember when the NMR (superconducting magnet as well) in our school "quenched". It's a hell of a lot of current to dissipate. Need to get some tech from Germany to come out and power it back up.
- lostlogin 14y agoAnd $75k ish of helium - which is getting pricier by the day, and can at times be impossible to source. And the riskiest time in terms of quenches, is during ramping. Our last quench re-occurred just as they finished ramping it. We were down for 3 weeks ish and the cost excluding helium was huge.
- lostlogin 14y agoRamping takes days (maybe even over a week). The RF is obviously off most the time though, and the gradient magnets are off too - these tend to be the evil bastards. The slew rate messes with your balance and after a few you come to dislike certain sequences - gradient echoes, diffusion and a few other - loud with high slew rates. You feel like your spinning and this causes slight nausea (in me) and 10 minutes or so of vertigo. Edit for spelling
- skue 14y ago> ballistically destroy stuff Not just "stuff," people have been killed this way. http://www.mrisafety.com/safety_article.asp?subject=39
- iamdann 14y agoPeople with magnet implants have had MRIs, though. http://stevehaworth.com/main/?page_id=871 http://stevehaworth.com/main/?page_id=871
- lostlogin 14y agoJust hope that the area to be scanned isn't near the implant. The susceptibility artifact will ruin the images and mask nearby problems.
- lostlogin 14y agoMR tech here. I once had a minor accident with an angle grinder (well, I've had a few, but this one had side effects) and got several minuscule steel fragments in a finger. I didn't know this had happened, except that once at work (edit: I work on 3T scanners) I could feel them in my finger. They were slightly sore, and very annoying. A few x-rays later I managed to localise them and with the help of a colleague, dug them out with a needle. I never did find them, but we got them out. I have scanned quite a few people with various sorts of shrapnel in them. Only once was it a problem for the patient (moderate pain) but we don't take the scary ones in - intraocular metallic fragments, one deep in a neck etc.