For most of the buildings from communism era - all the utilities run through the apartments anyway and there is absolutely no place or way to retrofit these uti
by margor 1mo ago
For most of the buildings from communism era - all the utilities run through the apartments anyway and there is absolutely no place or way to retrofit these utilities without extensively either re-doing it from scratch, or trying to somehow retrofit it on the outside.
All of these options are a non-starter considering basic AC starts from $500. Why should anyone invest more than that?
- xattt 1mo agoMany communist-era buildings had a service shaft the width of the back wall of the toilet closet (yes, bathroom and toilet are separate rooms). This was hidden from everyday view with large cabinet doors. A national-scale project can likely package cooling for these shafts, possibly emanating from rooftop units.
- deleted 1mo ago[deleted]
- numpad0 1mo agoPermissions and structural concerns aside, you only need one 65mm/2.5" hole in the wall to run the high/low pressure gas lines, a drain hose, and a power cable, plus couple more non-penetrating drill holes on the wall to mount the inside and outside units. You'll need a hole saw attachment on a drill, a vacuum pump to thoroughly dry out the system, and bits of plastic putty to fill the hole against intrusion. It's a less than 5 man-hour job.
- Markoff 1mo agoyou don't really need drain hose for outside multisplit unit, my AC drain hoses from all indoor units are connected to my WC tank, I used previously pumps to push the water to the roof, but they were not reliable and once after thunderstorm they died when I finally went for passive solution, should have done it from the beginning)