Ideally yes. For me I found following the code difficult. Then compound that with needing to know the NECA <https://www.necanet.org/topics/codesandstandards/nei
by krn1p4n1c 1mo ago
Ideally yes. For me I found following the code difficult. Then compound that with needing to know the NECA <https://www.necanet.org/topics/codesandstandards/neis/the-standards https://www.necanet.org/topics/codesandstandards/neis/the-st...> + the state codes. It's non-contiguous in the way it's written so you need to know the relevant sections and how to apply them together. Simple things add up; proper color coding of wiring, knowing how much sleeve to leave in at the edge of a box, what cable nuts are appropriate size for the number of wires bonded, size of box needed based on number of wires, how/where boxes can be mounted, space between EMT in bends, what size bus-bar is appropriate and what can share it.
- lstodd 1mo agoTo the first approximation you have to control thermal output of your wiring. Since it's I^2*R, you have to size your wires according to max sustained current, take into account thermal conductivity of where your wires are placed and keep all contacts tight. Also size circuit breakers according to that max current so they trip before the whole thing catastrophically overheats. Which is a trivial exersize in itself. Short-to-case and leak current protection (the reason for three-wire systems/PE conductors and differential protection) takes second place. In larger installations there are also considerations about grounding / ground loops, but that usually does not matter for residential. This is what the most of the code should be about (I never read US ones, but was doing apartments/small homes for like 20 years already). The rest, as in colors, sleeves and exact connectors used is helpful, but not critical, and if you think that a typical contractor would not botch it up in a most horrible way, well..