That’s largely correct but misses the point that the battery+pv system is legally only allowed to feed in 800W [1]. On our circuits you can draw ~3.5kW without
by hnaccount_rng 2mo ago
That’s largely correct but misses the point that the battery+pv system is legally only allowed to feed in 800W [1]. On our circuits you can draw ~3.5kW without tripping the breaker. This brings you to 4.3kW max load, which - as far as I understand - is still what all the circuitry must be rated for anyways.
The downside is that we have three phase power supply anywhere halfway recent. And that only gives you a single phase. In _most_ cases that’s fine, because you get a net-sum of all three phases at the meter, but technically you are only drawing/supplementing one out of three phases. In practice this likely doesn’t matter since different house put theirs on different phases and it all washes out.
[1] the DC side can have up to 2kW of panels. But that’s not visible to the grid
- Animats 2mo agoHome electrical load safety is based on distribution being a tree, with a breaker for each branch. The branch breaker will trip if there's an overload on that branch. Outlet strips with their own circuit breakers are sub-branches. This is all worked out in the US under the National Electrical Code, so that you can't overload a branch circuit without tripping a breaker. The UK uses BS 7671, which has the same goals but different topology. Residential users don't have to do load calculations or make measurements. This thing breaks the simplified rules that make home electrical safety work. The obvious way to get into trouble with this is to plug in two of them on a circuit with heavy loads. Now you have a big source and a big load without a breaker between them. Germany gets this, and requires that a licensed electrician add up the loads, check the topology, and do the install. One way to make this work safely would be to require a special symmetrical connector, with both sides protected against touch. That has to be on its own branch circuit, with a breaker between it and any loads. That becomes a legit place to plug in source devices. This is essentially the same as having a dryer or A/C outlet installed.
- hnaccount_rng 2mo agoYou are aware, that the normal Balkonkraftwerk is plugged in with a standard Schuko plug? This _only_ works because there is no licensed electrician involved. The personal cost would add at least 50% of the total expenditure and it is made safe by reducing the safety margin by the up to 800W that the Balkonkraftwerk supplies on that circuit