There have been discussions about this chip here in the past. Maybe not that particular one but previous versions of it. The whole server if I remember correctl
by elorant 8mo ago
There have been discussions about this chip here in the past. Maybe not that particular one but previous versions of it. The whole server if I remember correctly eats some 20KWs of power.
- neya 8mo ago20KW? Wow. That's a lot of power. Is that figure per hour?
- ipython 8mo agoIt’s 20kW for as long as you can afford the power bill
- deleted 8mo ago[deleted]
- deleted 8mo ago[deleted]
- deleted 8mo ago[deleted]
- deleted 8mo ago[deleted]
- ai-christianson 8mo agoIf you run it for an hour, yes.
- neya 8mo agoI asked because that's the average power consumption of an average household in the US per day. So, if that figure is per hour, that's equivalent to one household worth of power consumption per hour...which is a lot.
- jodrellblank 8mo agoConsumption of a house per day is measured in kiloWatt-hours (an amount of power like litres of water), not kiloWatts (a flow of power like 1 litre per second of water). 1 Watt = 1 Joule per second.
- neya 8mo agoThanks!
- cortesoft 8mo agoI think you are confusing KW (kilowatt) with KWH (kilowatt hour). A KW is a unit of power while a KWH is a unit of energy. Power is a measure of energy transferred in an amount of time, which is why you rate an electronic device’s energy usage using power; it consumes energy over time. In terms of paying for electricity, you care about the total energy consumed, which is why your electric bill is denominated in KWH, which is the amount of energy used if you use one kilowatt of power for one hour.
- mediaman 8mo agoOthers clarified the kW versus kWh, but to re-visit the comparison to a household: One household uses about 30 kWh per day. 20 kW * 24 = 480 kWh per day for the server. So you're looking at one server (if parent's 20kW number is accurate - I see other sources saying even 25kW) consuming 16 households worth of energy. For comparison, a hair dryer uses around 1.5 kW of energy, which is just below the rating for most US home electrical circuits. This is something like 13 hair dryers going on full blast.
- taneq 8mo agoAh yes, like those EV chargers that are rated at X kWh/hour.
- t0mas88 8mo agoYou would hope that an EV reporting x kWh/hour considers the charge curve when charging for an hour. Then it makes sense to report that instead of the peak kW rating. But reality is that they just report the peak kW rating as the "kWh/hour" :-(
- deleted 8mo ago[deleted]
- fodkodrasz 8mo agoWhat do you mean by "per hour"? Watt is a measure of power, that is a rate: Joule/second, [energy/time] > The watt (symbol: W) is the unit of power or radiant flux in the International System of Units (SI), equal to 1 joule per second or 1 kg⋅m2⋅s−3.[1][2][3] It is used to quantify the rate of energy transfer. https://en.wikipedia.org/wiki/Watt https://en.wikipedia.org/wiki/Watt
- ddalex 8mo ago20 kWh per hour
- dyauspitr 8mo agoThat’s wild. That’s like running 15 indoor heaters at the same time.
- zozbot234 8mo agoA first-gen Oxide Computer rack puts out max 15 kW of power, and they manage to do that with air cooling. The liquid-cooled AI racks being used today for training and inference workloads almost certainly have far higher power output than that. (Bringing liquid cooling to the racks likely has to be one of the biggest challenges with this whole new HPC/AI datacenter infrastructure, so the fact that an aircooled rack can just sit in mostly any ordinary facility is a non-trivial advantage.)
- elcritch 8mo agoWell for some. Google has been using liquid cooling to racks for decades.
- c0balt 8mo ago> Bringing liquid cooling to the racks likely has to be one of the biggest challenges with this whole new HPC/AI Are you sure about that? HPC has had full rack liquid cooling for a long time now. The primary challenge with the current generation is the unusual increase of power density in racks. This necessitates upgrades in capacity, notably getting 10-20 kWh of heat away from few Us is generally though but if done can increase density.
- jmalicki 8mo agoHPC is also not a normal data center but also usually doesn't have the scale of hyperscaler AI data centers either.
- mlyle 8mo ago> The liquid-cooled AI racks being used today for training and inference workloads almost certainly have far higher power output than that. 75kW is a sane "default baseline" and you can find plenty of deployments at 130kW. There's talk of pushing to 240kW and beyond...