And all these huge new data centers are gonna make things worse: https://www.eesi.org/articles/view/data-centers-and-water-consumption https://www.eesi.org/arti
by MeteorMarc 8mo ago
And all these huge new data centers are gonna make things worse: https://www.eesi.org/articles/view/data-centers-and-water-consumption https://www.eesi.org/articles/view/data-centers-and-water-co...
- pfdietz 8mo agoThe idea that data centers are huge water hogs is nonsense.
- margalabargala 8mo agoData centers consume enormous amounts of water for evaporative cooling. What part is nonsense? If the data center is built somewhere with ample water supplies this isn't an issue. If it's pulling from groundwater this can be a huge issue. Groundwater isn't infinite and is being depleted in many areas.
- estearum 8mo agoI was under the impression they capture the evaporation, let it cool, and recycle it?
- sidewndr46 8mo agoI guess it's possible to have a condensing station, but generally speaking you'd need to supply input energy to allow it to cool down and condense somehow. The bigger question here is if a datacenter using evaporative cooling where does the moisture go? If it just feeds a cloud system that rains on nearby fields, it's not much different than irrigating crops. If it feeds clouds that go offshore and rain into the ocean, it's similar to just diverting drinking water into the ocean
- 306bobby 8mo agoI must be missing something, why can't it be entirely closed loop like a water radiator in an old car? A simple fan running through large radiator cores would certainly condense within the system, keeping the water in the system
- quickthrowman 8mo agoA closed loop system has a COP of 4, adding in cooling towers almost doubles that to 7. You can reject 1.75x more heat for the same amount of electricity by adding evaporative cooling towers. COP is coefficient of performance.
- pfdietz 8mo agoOne thing to remember is that much of the waste heat from your car's engine goes out the exhaust, not out the radiator. I think the two are often about equal.
- pfdietz 8mo agoA 1 GW heat source evaporates about 9 million gallons per day. In 2024, US data centers consumed power at an average rate of about 21 GW. So, that would be about 70 billion gallons per year evaporated.
- deleted 8mo ago[deleted]
- pfdietz 8mo ago> I was under the impression they capture the evaporation, let it cool, and recycle it? So, how do they get rid of the latent heat of evaporation that's released when the water recondenses? The whole point of evaporative cooling is to soak up that latent heat and release it later, out in the environment, when the water recondenses somewhere else. It's kind of like why Dune's stillsuits don't work.
- moomoo11 8mo agoThey’ll be built and deployed in space soon. Elon said so.
- PaulKeeble 8mo agoThe reason they consume water is the same reason space is a bad place to put data centres, getting rid of the heat is a challenge. Having only radiative heat dissipation is going to severely limit space based manufacture and computing, it puts significant constraints on the space station already.
- moomoo11 8mo agoyeah but Elon said so and thus it must be true
- michaelt 8mo agoIn the USA, data centres consume about 164 billion gallons of water annually [1] Irrigation consumes 118 billion gallons per day [1] and thermoelectric power plants a further 133 billion gallons per day. There's enormous amounts, and there's enormous amounts. If you really want to get mad about water being wasted, look up what californian alfalfa growers pay for their water. [1] https://www.eesi.org/articles/view/data-centers-and-water-consumption https://www.eesi.org/articles/view/data-centers-and-water-co... [2] https://pubs.usgs.gov/fs/2018/3035/fs20183035.pdf https://pubs.usgs.gov/fs/2018/3035/fs20183035.pdf
- rapatel0 8mo agoNew datacenter projects are usually closed loop now. From your first citation: > Closed-loop cooling systems enable the reuse of both recycled wastewater and freshwater, allowing water supplies to be used multiple times. A cooling tower can use external air to cool the heated water, allowing it to return to its original temperature. These systems can reduce freshwater use by up to 70%.
- quickthrowman 8mo agoCitation please, I don’t buy it. Evaporative cooling towers almost double the efficiency of heat rejection vs a closed loop system. I don’t see any data center operator giving up those operating cost efficiency gains just to save some water, but I could be wrong.
- rapatel0 8mo agoAs i stated, It's literally in the first link from the OP.
- quickthrowman 8mo agoYeah, I still don’t buy it. No data center operator is going to use almost twice as much electricity to operate their cooling system if they could install evaporative cooling towers and almost double the efficiency of heat rejection. You can remove 7W of heat for 1W of electricity with a cooling tower, it’s 4W for 1W with a closed loop system. I could see them doing it in a humid area where you can barely get any cooling from evaporation due to the air being satured, but that only covers the Deep South and Florida in the US. I don’t care if some company operating data centers claim that they’re aiming for closed loop cooling systems when the economics favor open loop cooling. Show me the incentive and I’ll show you the outcome, the incentive to increase profit by using cooling towers will beat out the abstract good feeling you get from not using evaporative cooling towers and paying almost twice as much to reject heat from your data center which you only operate to make a profit.
- rapatel0 8mo agoMost new datacenters use closed loop systems now. the water just circulates.
- ktm5j 8mo agoThe water used by data centers are either closed loop, meaning that they recirculate a set amount of water.. or the water evaporates, and my understandingis they don't use potable water for those systems. I might be wrong, but I don't think data centers aren't destroying potable water.
- nunobrito 8mo agoThe water is reutilized, a big reason is the difficuty to filter new incoming water because of impurities and uncertainty about quality (e.g. winter times make the river water very muddy and difficult to filter). Second because is because adding water is a cost, whereas reuse existing water is simpler and saves money. There are always losses of water, however these are neglectible. Not mentioned here but for more extreme cases of devices cooling is done with distilled water (zero minerals) and the whole device works submerged under this water, the hot water isn't thrown away because it distilled water takes a lot of effort to remove the minerals and effort to keep them out, so the closed loop is very efficient.
- stevenwoo 8mo agoHere's one in Oregon from today's San Francisco newspaper. If they recycle, it's still loses enough equivalent to 4000 people a year. Maybe that's worth it, but it reads like it's not enough for their future plans. It's not like the city population in question has changed that much historically so there's some future expansion of something planned. That water sounds very pristine since they are going to have to take over national park land. https://www.sfgate.com/national-parks/article/mount-hood-water-google-21307223.php https://www.sfgate.com/national-parks/article/mount-hood-wat...
- garg 8mo agoMicrosoft is piloting new zero water cooled datacenters in some locations https://www.axios.com/local/des-moines/2026/01/16/microsoft-west-des-moines-data-center-water-zero https://www.axios.com/local/des-moines/2026/01/16/microsoft-...? Hopefully this can be the new standard.
- b65e8bee43c2ed0 8mo agoyes, yes, AI bad. https://substackcdn.com/image/fetch/$s_!Dy-x!,w_1272,c_limit,f_webp,q_auto:good,fl_progressive:steep/https%3A%2F%2Fsubstack-post-media.s3.amazonaws.com%2Fpublic%2Fimages%2F6e4896d1-bd3d-416e-8ae3-46c8f8809cb9_2486x536.png https://substackcdn.com/image/fetch/$s_!Dy-x!,w_1272,c_limit...