4 ms·
The advantage of far UVC over other UV air cleaning solutions is that it doesn't need to be ducted. This means that you can kill microbes right when they leave
by elil17 9mo ago
The advantage of far UVC over other UV air cleaning solutions is that it doesn't need to be ducted. This means that you can kill microbes right when they leave someone's mouth - you don't need to wait for them to be sucked through an air handler.
- toomuchtodo 9mo agoI'm curious if plastics embrittlement is a problem with Far-UVC. I recently was putting a large evaporative humidifier [1] through its paces for someone to get my opinion, and a challenge was that you had to clean the water tank that was the foundation of the unit fairly frequently (every few days). I provided feedback to the manufacturer that a far UVC bulb in the tank might be useful for reducing cleaning intervals. For use cases where the emissions are contained (HVAC, water tanks, etc), I think it's a slam dunk from an electronic antiseptic perspective. UV is somewhat common in water filtration today, but perhaps an improvement is possible if these bulbs last longer than existing UV solutions. [1] https://levoit.com/collections/humidifiers-diffusers/products/superior-6000s-smart-evaporative-humidifier-2026 https://levoit.com/collections/humidifiers-diffusers/product... (I do not recommend the humidifier by the way, simply too much work to keep the water tank and the evaporation panels clean, I recommend an ultrasonic version instead)
- elil17 9mo agoI do not believe that there is a good understanding of the impact of far-uvc on plastic embrittlement.
- toomuchtodo 9mo agoDelightful, an experiment to be run!
- TeMPOraL 9mo agoThere's research to be done On the people who are Still alive. ♫♪
- vbelenky 9mo agoTwo studies that I'm aware of, but yeah, data is thin on the ground: https://www.mdpi.com/2076-3417/13/7/4141 https://www.mdpi.com/2076-3417/13/7/4141 https://www.boeing.cn/cti/downloads/Boeing-Compatibility-of-Aircraft-Interior-Surfaces-with-222-nm-Far-UV-Light-Exposure.pdf https://www.boeing.cn/cti/downloads/Boeing-Compatibility-of-... Summarized here, along with other materials considerations: https://blueprintbiosecurity.org/u/2025/06/Blueprint-for-Far-UVC-V1.0-9.22.25.pdf#page=134 https://blueprintbiosecurity.org/u/2025/06/Blueprint-for-Far...
- SV_BubbleTime 9mo agoAlong the same lines… where is the proof that as the unit ages it doesn’t leave the magic 220nm range? It is complete nonsense to point this at people.
- vbelenky 9mo agoHere's a paper: https://www.jstage.jst.go.jp/article/lsj/50/7/50_394/_pdf https://www.jstage.jst.go.jp/article/lsj/50/7/50_394/_pdf This is a study of the Ushio Care222 unit, but its underlying physics is the same as any other KrCl excimer lamp, so its pretty implausible for other KrCl lamps to exhibit spectral drift when this one doesn't. The spectrum does change a bit over time--it actually gets less dangerous. But it's a very slight difference.
- SV_BubbleTime 9mo agoSo different hardware, a clinical unit designed for thousands of hours. Vs a very likely Shenzen unit that a teeny tiny group is selling on a basic website. And, you can make zero claims on whether a light spectrum of a led will go up or down over time despite one example. Amplifiers/voltages, coatings wearing down, oxide layers in diodes breaking down, etc.
- vbelenky 9mo agoI'm not sure what you mean by clinical unit--the ushio care222 is the longest lasting KrCl emitter I'm aware of, but as all bulbs age, they tend to degrade just by losing output, not by spectral shifting. Basically everyone in far-UVC is a teeny tiny group selling lamps on basic websites, even those who source care222 emitters from USHIO. It's not a big industry! We don't source our KrCl bulbs from Shenzen, but not for this reason. Yes, that's true about LEDs, but the physics of LEDs and excimer bulbs are different. Excimer spectra don't smoothly shift the way LED spectra do. Excimer spectra have characteristic peaks based on the energy levels of the possible gas molecule species present in the filler gas. The main change over time is the gradual reduction of the 259nm Cl2* peak, which is the main peak of concern--so it fails gracefully. Another possibility is the degradation of the dichroic filter coating under thermal stress--but I've only ever observed this in diffused units, none where the filtered glass is open to the air, and that will happen even on an Ushio bulb. Nukit is our competitor but I doubt very much that any concerning spectral shift will take place over the course of the lifetime of their lamp.
- JoshTriplett 9mo agoIt doesn't have to be, but you can avoid any concerns about looking into it or affecting the light quality in the room by doing so.
- elil17 9mo agoIf you were going to duct it then why wouldn't you just use regular UVC? Much cheaper.
- JoshTriplett 9mo agoFair point.