Alright, I have a dumb question... How come with a LAG group on ethernet, I can get "more total bandwidth", but any single TCP flow is limited to the max speed
by exabrial 1y ago
Alright, I have a dumb question...
How come with a LAG group on ethernet, I can get "more total bandwidth", but any single TCP flow is limited to the max speed of one of the LAG Components (gigabit lets say), but then these guys are somehow combining multiple fibers into an overall faster stream? What gives? Even round robin mode on LAG groups doesn't do that.
What are they doing differently and why can't we do that?
- bradfitz 1y agoBecause your switch is mapping a 4 tuple to a certain link and these people aren't, is my guess.
- eqvinox 1y ago> What are they doing differently and why can't we do that? You're (incorrectly) assuming they're doing Ethernet/IP in that test setup. They aren't (this is implied by the results section discussing various FEC, which is below even Ethernet framing), so it's just a petabit of raw layer 1 bandwidth.
- cycomanic 1y agoIt's also important to note that many optical links don't use ethernet as a protocol either (SDH/SONET are the common ones), although this is changing more and more.
- wmf 1y agoLooks like SDH/SONET topped out at 40 Gbps which means it died 10 years ago.
- meepmorp 1y agoSONET is widely used in the US.
- eqvinox 1y agoUsed, maybe, but [citation needed]. Built, no, definitely not voluntarily¹, Ethernet is the only non-legacy thing surviving for new installations for anything more than short range (few kilometer) runs. InfiniBand, CPRI and SDI are dying too and getting replaced with various over-Ethernet things, even for low-layer line aggregation there's FlexE these days. ¹ some installations are the exception confirming the rules; but as a telco sinking more money into keeping an old SONET installation alive is totally the choice of last resort. You'll have problems getting hardware too. Disclaimer: I don't know what military installations do.
- ryao 1y agoInfiniband is alive and well in HPC. 327 out of the top 500 machines use it according to this: https://www.top500.org/statistics/sublist/ https://www.top500.org/statistics/sublist/ It is a nice interconnect. It is a shame that the industry does not revisit the idea of connecting all components of a computer over infiniband. Nvlink fusion is a spiritual successor in that regard.
- eqvinox 1y agoYes, IB hasn't died… yet. But the writing's probably on the wall with Ultra Ethernet; the corporate development of Mellanox (now nVidia) is not a great sign either. (Also you don't use IB for 1800km WAN links.) FWIW I actually run IB and think it's a nice interconnect too :)
- ryao 1y agoThis seems oddly appropriate: https://xkcd.com/927/ https://xkcd.com/927/ There is one difference, however. As far as I know, they did not make Ultra Ethernet because the existing Infiniband standard did not cover everyone’s use cases. They made Ultra Ethernet because Intel killed QLogic’s Infiniband business in an attempt to replace an open standard (Infiniband) with a proprietary one (Omni-Path) that they made out of QLogic’s infiniband business’ corpse in an attempt to have a monopoly (which failed spectacularly in true Intel fashion), NVIDIA purchased Mellanox becoming the dominant Infiniband vendor, this move turned out to be advantageous for AI training and everyone else wanted an industry association in which NVIDIA would not be the dominant vendor. The main reason people outside of HPC care about Infiniband level performance is AI training and Nvidia’s dominance is not going anywhere. Now that NVIDIA has joined the UEC, it is unclear to me what the point was. NVIDIA will be dominant in Ultra Ethernet as soon as it ships Ultra Ethernet hardware. Are Nvidia’s competitors going to make a third industry association once they realize that Nvidia is effectively in control of the UEC because nobody can sell anything if it is not compatible with Nvidia’s hardware? Had they just used Infiniband, which they had spent billions of dollars developing just a few decades prior, they would have been further along in developing competing solutions. Reinventing the wheel with Ultra Ethernet was a huge gift to Nvidia. If they somehow succeed in switching people to Ultra Ethernet, what guarantee do we have that they will not repeat this cycle in a few decades after they have left the technology to become a single vendor solution due to myopic decisions and they decide to reinvent the wheel again? We already have been through this with Infiniband and I do not see much reason that anyone should follow them down this road again.
- wmf 1y agoI assume this is just a PHY-level test and no real switches or traffic was involved.
- toast0 1y agoYou don't really want to, but if you configure all of the LAG participants on the path to do round-robin or similar balancing rather than hashing based on addresses, you can have data in one flow that exceeds an individual connection. You'll also be pretty likely to get out of order data, and tcp receivers will exercise their reassembly buffer, which will kill performance and you'll rapidly wish you hadn't done all that configuration work. If you do need more than one link's worth of throughput, you'll almost always do better by running multiple flows, but you may need still need to configure your network so it hashes in a way that you can get diverse paths between two hosts, defaults might not give you diversity even on different flows.
- exabrial 1y agothe data out of order is the key bit. How do these guys get the data in order and we dont?
- aaronax 1y agoConsider that a QSFP28 module uses four 25gbps lanes to support sending one single 100gbps flow. So electronics do exist that can easily do what you are asking. I think it is just the economics of doing it for the various ports on a switch, lack of a standard, etc.
- Polizeiposaune 1y agoSFP/QSFP/PCIe etc., are combining multiple lanes originating from a physical bundle of limited size; transmitters could easily share a single clock source. The wire protocol includes additional signalling that lets the receiver know how to recombine the bits coming over each lane in the correct order. In contrast, Ethernet link aggregation lets you combine ports that can be arbitrarily far apart -- maybe not even within the same rack (see MC-LAG). Ethernet link aggregation doesn't add any encapsulation or sequencing information to the data flows it manages. You can imagine an alternate mechanism which added a small header to each packet with sequence numbers; the other end of the aggregation would then have to remove that header after sorting the packets in order..
- ryao 1y agoI do not know exactly what is being done here, but I can say that I am aware of two techniques for sending bit streams over parallel wires while keeping the bits in order: 1. The lengths of all wires are meticulously matched so that signals arrive at the same time. Then the hardware simply assumes that the bits coming off each wire are in sequence by wire order. This is done in computers for high speed interfaces such as memory or graphics. If you have ever seen squiggly traces on a PCB going to a high speed device, they were done to get the lengths to be exactly the same so the signals arrive at the same time across each. This is how data transfers from dual channel DDR4 RAM where 64 bits are received simultaneously occur without reordering bits. 2. The lengths of wires are not matched and may be of different lengths up to some tolerance. Deskew buffers then are used to emulate matched lengths. In the case of twisted pair Ethernet, the wire pairs are not equal length because the twist rates vary to avoid interference from having the same twist rates. The result is the Ethernet PHY must implement a deskew buffer to compensate for the mismatched lengths and present the illusion of the wire lengths being matched. This is part of the Ethernet standard and likely applies to Ethernet over fiber too. The IEEE has a pdf talking about this on 800 Gb/sec Ethernet: https://www.ieee802.org/3/df/public/23_01/0130/ran_3df_03_230130.pdf https://www.ieee802.org/3/df/public/23_01/0130/ran_3df_03_23... LAG was never intended to have the sequence in which data is sent be preserved, so no effort was made to enable that in the standard. That said, you would get a better answer from an electrical engineer, especially one that builds networking components.
- ryao 1y agoI just noticed a typo in this. I should have written 128 bits, not 64 bits. Data transfers in dual channel DDR4 are 128-bits at a time.
- myself248 1y agoThey're not combining anything, they're sending 19 copies of one signal down 19 strands (with some offsets so they interfere in awkward ways), applying some signal processing to correct the interference which they say makes it realistic, and declaring that they've calculated the total capacity of the medium. What you do with it at the higher layers is entirely up to you. But, ethernet could totally do that, by essentially demuxing the parts of an individual packet and sending them in parallel across a bunch of links, and remuxing them at the other end. I'm not aware of anyone having bothered to implement it.
- RationPhantoms 1y agoFlex Ethernet will allow for that but it's been a long time coming.