Look at ISO 7730, a lot of comfort comes from non-cold walls and their radiant heat and small difference of wall temperatures to air temperatures. So having a t
by looofooo0 1y ago
Look at ISO 7730, a lot of comfort comes from non-cold walls and their radiant heat and small difference of wall temperatures to air temperatures. So having a thoroughly heated home allows you to lower your air temperature. Apart from that modern gas and even more heat pumps greatly gain efficiency by lowering flow water temperatures.
- Retric 1y agoIt’s a deep rabbit hole as condensation, humidity, etc also enter the picture. Efficiently lowering temperatures for sleeping further complicates things. That said, heat loss is through exterior surfaces so you really want to avoid spot heating of poorly insulated exterior walls. Thus the design of baseboard heaters can make a larger impact than you’d think.
- looofooo0 1y agoBaseboard heaters need very high temperatures. I would not recommend installing this anywhere. Having big Typ 33 heaters for temperatures below 45°C will greatly increase efficiency of your heating system. Otherwise, a split air con is also an efficient way of heating.
- sokoloff 1y agoBaseboard heaters are often sized such that very high temps are needed (because that's what cheapest/lowest labor/least space used), but they don't have to be sized that way. In the attic bedroom, we have baseboards around the entire perimeter on two walls and same in the bath. I run the attic zone on the same water temp (outdoor reset controlled to be quite low) as the rest of the house (mostly large cast iron rads, one cast iron convector). Good insulation and air sealing in the attic means that the attic zone calls way less than the downstairs.
- looofooo0 1y agoWhich is not exactly efficient. 40C or less is desirable.
- sokoloff 1y agoMy return water temps are 115F (46C) on a P98 design heating day, and obviously cooler on warmer than design days. Cooler is always better, but "baseboards require 180F [82C] water because that's what's on the spec sheet" is a commonly-held but mistaken belief.
- looofooo0 1y agoThis is bad. Return water should be less 35 degree max. Actually 30 degree after the heat pump would be ideal: https://www.flow30.de/ https://www.flow30.de/
- jillyboel 1y ago[citation needed]
- looofooo0 1y agoAh this is school knowledge of thermodynamics: the smaller the delta the more efficient the heat pump. For human comfort look at the iso7730. Also the system is self regulatory with such low temps.
- Retric 1y agoHeat pumps and furnaces behave very differently here. For a furnace you’re talking fractions of a percent difference in efficiency across a wide temperature range so by far the most critical issue is total heat losses to the outside. A heat pump’s efficiency is far more variable making total losses to the outside less important.
- 1y ago
- aesh2Xa1 1y agoHaving read that document, the ISO 7730 model itself depends on stable temperatures. However, I think the key is simply to understand thermal mass; people can be in hotter air, but feel cold due to cold surfaces (e.g., floors or furniture), which heat more slowly (or lose heat more slowly) than the air itself. Therefore, 1st: Heating/cooling cycles from your HVAC are fighting these objects because they don't mix at the same speed as other objects (e.g., the air itself), so you end up with gradients across objects; people rate this feels unpleasant. 2nd: Mechanical equipment tends to operate more efficiently under constant load compared to constant start and stop cycles. With #1 and #2, you can just heat constantly to increase both the uniformity of heating across objects and also the efficiency of the mechanical equipment's energy conversion. There's a 3rd point, which, really, is just a sneaky way of reframing #1 and #2, and that is that you can also lower your setpoint and still have a subjectively superior comfort perception compared to a cyclic system. It drives home the point to say "constant 68F feels more comfortable than intermittent 72F." But it also invites the complaint about constant versus intermittent energy use, right? So I think just detailing #1 and #2 is better.
- looofooo0 1y agohttps://www.krantz.de/wp-content/uploads/2024/04/layout-specifications-for-thermal-comfort-.pdf https://www.krantz.de/wp-content/uploads/2024/04/layout-spec...
- aesh2Xa1 1y agoThat spec aligns with my understanding, including the model's dependence on comfort perception. I was, initially, in disbelief about it, but changed my mind after reading thru. The texty reply was to make it more palatable for someone like me to accept. I think we agree. One thing I missed in summary is the concept of general radiant temperature gradient. It's not only about the gradient for conduction, but for radiation (and convection). So you could probably improve my summary by talking about any gradient between different objects in the environment and their EM, which feels unpleasant (but I think it had value in its reduction of the problem, too).