Handheld detector for all types of ionizing radiation improves radiation safety
- goda90 2y agoIt claims it detects all ionizing radiation but doesn't list high energy UV among the things detected.
- blueflow 2y agoLike UV light, alpha radiation is easily shielded by most kinds of material. Even after skimming the linked publication, it does not seem clear to me how the alpha radiation (and UV) would reach the devices sensor. Probably something behind "... and measure alpha and beta radiation from contaminated surfaces".
- thyristan 2y ago"Shielding" is a relatively crude term. Alpha radiation is "shielded" by a sheet of paper in the sense that the attenuation is so high, and the attenuation length is so short when compared to the thickness of that paper, that less than 1/1000th of the original particles arrive on the other side of the paper. However, this means that there are still very few but not zero alpha particles arriving on the other side. Plus, the energy of those alpha particles doesn't just go away, it will be either transformed into highly energetic photons (in the hard UV to gamma range) or it will ionize the attenuating medium, leading to photons from line emissions (infrared to visible to UV) or other ionization-related effects (e.g. an ionisation current in semiconductor diodes). All those things can be detected, and you can calibrate your detector for the relative sizes of those effects you are seeing when compared to the incident alpha rays.
- mppm 2y agoThis is somewhat inaccurate from a physical perspective. What you say would be applicable to the attenuation of gamma rays, which is governed by low-probability interactions and is therefore exponential. But alpha particles, being charged an heavy, lose energy continuously through electron interactions and have a relatively fixed range in matter, beyond which the incidence is practically zero.
- thyristan 2y agoNo, that is just plain wrong. All attenuation is exponential (except very special stuff like energy resonances at certain particle energies). You just get very different exponents for rarely vs. frequently interacting particles. The charge of an alpha particle is also only twice the charge of a beta particle with a far higher (orders of magnitude, not just a factor of 2) penetration depth. The relevant difference is actually the mass and size (i.e. cross-section) of an alpha particle that makes it far more frequently interacting. There are some more differences that govern the cross-section like conservation of momentum and angular momentum in certain interactions where there are differences between gamma and alpha particles. Or magic number nuclei that are relevant for neutron absorption. But in general, for a given material and particle, attenuation is always always always exponential over the penetration depth vs number of particles, until you hit a low enough energy that some other mechanism for energy transfer can come into play or become unavailable, where the exponent will change and you will see a change in slope.
- mppm 2y agoPlease take a look at slide 11 of this presentation [1]. Stopping power and Bragg peak (slide 30) are also relevant concepts. What you are describing applies to photons and neutrons, but not to charged particles. 1. https://indico.cern.ch/event/975141/contributions/4137563/attachments/2156087/3646193/2020-Lecture-3-Interactions%20of%20Particles%20with%20Matter.pdf https://indico.cern.ch/event/975141/contributions/4137563/at...
- thyristan 2y agoWell then, please read what those slides say. Then read what I wrote. The Bragg peak is about energy deposition, not the number of particles arriving at some point. When the energy of a particle changes going through the medium, the absorption changes. Still an exponential curve, just piece-wise exponential. Look at slide 11, that cutoff. Look at the logistic formula for it and its limit going right: still an exponential.
- theglocksaint 2y agoShielding is not a crude term, it is indeed used as technical language in the world of radiation safety. You are also using the term attenuation incorrectly, as sibling comment points out.
- thyristan 2y agoShielding in radiation safety means attenuation to a safe level. But for detection, that is irrelevant because radiation detectors can be very sensitive, such that even very minute quantities making it through a "shielding" are still sufficient. When in doubt, you just increase integration time to almost forever and you will still get a sufficient number of particles to get a measurement.
- tzs 2y ago> Plus, the energy of those alpha particles doesn't just go away, it will be either transformed into highly energetic photons (in the hard UV to gamma range) or it will ionize the attenuating medium, leading to photons from line emissions (infrared to visible to UV) or other ionization-related effects (e.g. an ionisation current in semiconductor diodes). Why can't it end up as thermal energy in the attenuating medium instead?
- thyristan 2y agoBecause thermal energies are far lower than what those particles are depositing. The thermal movement at those energies would still be ionizing because it would some nucleus away leaving a few stray electrons in the lattice. But of course, sooner or later the secondary, tertiary, ... particles will end up as thermal energy. And of course any ionization always has a thermal component, the lattice will always get a transfer of momentum.
- jjtheblunt 2y agomaybe it infers alpha radiation from detection of decay chain particles / photons at energies indicative of alpha presence.
- momoschili 2y agoUV-C radiation is so rare in our lives and even in specific work environments that unless you have a very special need for it, you don't need to detect it. As far as I know, it's mostly just germicidal lamps and arc lamps that generate enough UV-C to be of any real concern, and in that case the operator knows about it.
- weinzierl 2y agoAgreed that a detector would not help but some UV-C lamps are sold freely with arguably insufficient warnings. Is das folgende Geraet sicher? https://www.doctor-san.eu/luftreinigung-desinfektion/uvc-desinfektionslampen/tragbarer-led-uv-c-desinfektionsstab-mit-akku.html https://www.doctor-san.eu/luftreinigung-desinfektion/uvc-des... https://www.doctor-san.eu/luftreinigung-desinfektion/uvc-desinfektionslampen/kleiner-reise-led-uv-c-desinfektionsstab.html https://www.doctor-san.eu/luftreinigung-desinfektion/uvc-des... https://www.amazon.de/Doctor-San-Sanierungstechnik-Desinfektionslampe-UVC-Desinfektionsstab/dp/B08ZSKC1YR/ref=mp_s_a_1_3?crid=2DPH5HW20X7KF&dib=eyJ2IjoiMSJ9.ePHJbu3UTpDRVjXt8SgKtGS6fjkngca7y2_LB242ENkRa4LIyBsCMtCe6EVSQJGKj6sEL15jbVe6Ccn4gCVXCrSkl-0DO6ooU-TEdUhrQbiOKigDrOJOI_s6gfZ0qK4zrDgdDgxgsdx-MNuB2HRQR9M688GjHdiZMfNt9nD3vyHQzWH6YOujixfHtYkqKKkV4PSzj5k0OFD3BX0Mrw4BAQ.0Lr-4oqg7ajcR7353tHarOIm7MepXqOsimGyaifJhyM&dib_tag=se&keywords=dr+san+uv-c+lampe&qid=1745338920&sprefix=dr+san+uv-c+lamps%2Caps%2C104&sr=8-3 https://www.amazon.de/Doctor-San-Sanierungstechnik-Desinfekt...
- momoschili 2y agointeresting, you're right they are devoid of warnings. I thought maybe it was an EU/Germany thing, but looking at American listings it's similar. This may be due to the level of UV-C exposure you're getting. EG weak laser pointers won't have the same caution signs as a Class IV laser. Edit: Looking into it a bit more, seems that "far-UVC" light is a bit higher energy than the typical "UVC". It seems that far-UVC penetrates less deeply and critically is apparently much better absorbed by the dead layers of the skin than UVC, so it is currently recognized as safe... All I could find on it was a Columbia research artcle.
- frozencooler 2y ago>The device can be used by industrial and medical radiation users, regulatory authorities, the nuclear energy industry, first responders and military users It cannot be used by TSA employees. They are not allowed to even wear dosimeters.
- KMnO4 2y agoTSA employees can use them, they are just not permitted to (for some reason).
- toomuchtodo 2y agoFederal liability around future health concerns. Edit: https://www.cdc.gov/niosh/hhe/reports/pdfs/2003-0206-3067.pdf https://www.cdc.gov/niosh/hhe/reports/pdfs/2003-0206-3067.pd...
- PaulHoule 2y agoThose big backscatter X-ray machines [1] have a powerful X-Ray tube. Not that I'd be worried if I flew once a month, but if I was a member of the aircrew and going through more than once a day I'd be concerned. Think about when you get a medical or dental X-Ray and the operator puts on a lead apron and goes around a corner -- they don't get anywhere near the dose that you get, but they are around the machine all the time time. TSA staff did none of that. Those machines were killed off because it was easy to demonstrate walking right through them and not getting detected if you wear a gun in a holster the way you would normally wear a gun if you weren't trying to hide it. The trouble is it depends on the gun being between you and the scanner because the gun appears black against the white radiation bouncing back from all the hydrogen atoms in you. With no background the gun is black-on-black and invisible. When people realized you could put a cop in front of the scanner and demo that the scanner couldn't see his gun it got around quickly that the scanner was worthless. [2] [1] https://en.wikipedia.org/wiki/Backscatter_X-ray https://en.wikipedia.org/wiki/Backscatter_X-ray [2] Ok, instead of getting scanned twice on your front and back they could scan you four times but this is getting ridiculous.
- 2y ago
- weinzierl 2y agoThe problem with regular Geiger counters is that the sensitive ones saturate and you risk missing being in a high radiation environment. The models built for civil protection are not sensitive enough for daily use. Luckily scintillation counters, like the one from the article seems to be, became really cheap in the past few years. I have a RadiaCode and it is a device one could only dream of a decade ago.
- thadt 2y agoKinda neat that they were able to marry all those different scintillators together in one package, but their paper makes it sound like you're still going to want an He3 tube along if you really care about finding neutrons.
- manmal 2y agoTangentially related: If you haven’t already, I‘d suggest to look at Radon. It‘s the #2 reason for lung cancer, and is very easy to measure and mitigate (automatic ventilation). Many countries have Radon hazard maps.
- perching_aix 2y agoIn the meantime I was recommended a spa day at a place with Radon gas because it's so good for me health wise supposedly. Irony through the roof.
- yababa_y 2y agoWell, if the exposure isn’t chronic, there might be a hormetic effect? Radiation dosage is the “classical” example of hormesis
- alnwlsn 2y agoLet's just hope they are lying. Where do you even get radon gas? The most stable isotope has a half life of just 3.8 days. Unless they mean they built on a place with unfortunate geology or have a large stockpile of radium around.
- jerlam 2y agoThere are caves and mines that have radon from natural sources. Why are people hanging out in Montana's radon-filled mines? https://www.mtpr.org/montana-news/2023-01-18/why-are-people-hanging-out-in-montanas-radon-filled-mines https://www.mtpr.org/montana-news/2023-01-18/why-are-people-...
- defrost 2y agoGranite sided valleys fill every day with radon until wind clears it out. Certainly not as dense as basements and caves but worth pointing out that radon is a constant ongoing decay product of natural uranium in rock.
- 2y ago
- 1970-01-01 2y agoYes, we're all still waiting for the medical tricorder.