1. High-level, the post is all wrong. The point should be that you always need to make sure you can pull new cable. The poster illustrates this: single mode, mu
by timzaman 2y ago
1. High-level, the post is all wrong. The point should be that you always need to make sure you can pull new cable. The poster illustrates this: single mode, multi mode, non-fiber, etc, etc. And if one "goes bad", you still can't run a new one, unless you have a pullstring.
2. The post cannot apply to fast/large networks - will be prohibitively expensive.
3. If running a few at home, I suggest to run MTP/MPO. It's basically a structured cable that can have around 12 fibers in them, plenty of future expansion.
Though I'll always run a large awg >>cat6 everywhere so it supports PoE++
- bananapub 2y agowhat a bizarre reply. the author is a sysadmin, who can definitely change what is plugged in to the switches their employer has chosen to buy, but doesn't have the power to make physical changes between multiple buildings, easily authorise opex spending on cable pullers or retrain as a cable puller. please actually consider what you're replying to before pushing the REPLY button.
- hinkley 2y agoPull strings don’t give you a way to pull new cables. They give you a backup way to pull new cables. Every cable in a conduit can be used to pull its own replacement or 2. But if anything goes wrong, you have a second chance before you have to go find the fishing rod.
- dsr_ 2y ago> 2. The post cannot apply to fast/large networks - will be prohibitively expensive. The expensive parts of fast/large networks are not the fiber strands. * right of use / lease * trenching and laying and covering * amplifiers on long lines * repair/maintenance * endpoints ... which is why the first thing you upgrade are the endpoints, and the last you do is lay more fiber. Get the most you can afford (often physically) at the beginning.
- stronglikedan 2y ago> And if one "goes bad", you still can't run a new one, unless you have a pullstring. The one that went bad is the pullstring.
- avidiax 2y ago> The one that went bad is the pullstring. That works for short runs, but for long runs, the only way to pull the cable without breaking it is to use wire pulling lubricant. And there's no guarantee that the cable you are pulling is undamaged. Rats don't improve pull strength, and even an electrically good cable can have the tensile strength cord severed. If you are in that situation, pulling the old cable with dried lube on it may snap it in two, especially if it's pulling the new strand. That's why leaving a pulling tape in each conduit is a good idea.
- sponaugle 2y agoThis is correct - I have pull strings in my conduits at my house for that reason. Pulling fiber down my 1000ft driveway would be difficult to do if the pull string was another fiber. You can pull a new pull string in empty conduit pretty easily with a shop vac and a ziploc bag.
- deleted 2y ago[deleted]
- liotier 2y ago> 2. The post cannot apply to fast/large networks - will be prohibitively expensive. Yes, it is obviously about small-scale sysadmin cabling. Telco networks have wildly different economics.
- throwaway2037 2y ago> If running a few at home, I suggest to run ... that can have around 12 fibers in them, plenty of future expansion. What kind of home network needs 12 fibers on a single run!?
- WorkerBee28474 2y agoTautologically, a high-bandwidth one.
- sponaugle 2y agoI ran fiber when I built my house a few years ago. I have MANY 12 fiber runs going to my IDF/MDFs, Server room, the gate, the dmarc, etc. I also ran SM fiber to every AP location. Out of 20 miles of pulls about 1 mile was fiber.
- mschuster91 2y ago> 3. If running a few at home, I suggest to run MTP/MPO. It's basically a structured cable that can have around 12 fibers in them, plenty of future expansion. For a homelab honestly just pull pre-terminated cable with LC connectors, a 20 or 25mm hollow pipe is enough. That way you don't need a splicer machine, experience on how to operate it, or measuring equipment.