3 ms·
Total GCR dose is 3-5x in transit to Mars compared to what you get on ISS; on the Martian surface it's from 1.5-2x the ISS dose. (see https://www.swsc-journal.o
by idlewords 2y ago
Total GCR dose is 3-5x in transit to Mars compared to what you get on ISS; on the Martian surface it's from 1.5-2x the ISS dose. (see https://www.swsc-journal.org/articles/swsc/pdf/2020/01/swsc200013.pdf https://www.swsc-journal.org/articles/swsc/pdf/2020/01/swsc2...).
On a long-stay Mars mission, that adds up to 12-18 times the accumulated GCR exposure compared to a six-month ISS increment.
- Robotbeat 2y agoAh, you’re being tricky. You’re ignoring the substantial trapped radiation dose on ISS (it is, after all, the total dose that causes the defects). That, combined with GCR, gives an equivalent dose the same at Curiosity altitude as on ISS. In fact, look at Table 2. It shows that at ISS, the dose from the SAA is about the same as the GCR dose, so by ignoring trapped radiation, you’re manipulating the result by a factor of 2.