In the UK, where almost everyone has an electric kettle, almost all are 3kW. Our electric circuits aren't rated for 13A continuous draw (e.g. plug-in EV charge
by gmac 2y ago
In the UK, where almost everyone has an electric kettle, almost all are 3kW.
Our electric circuits aren't rated for 13A continuous draw (e.g. plug-in EV chargers should be set to 8A or 10A), but they are fine at 13A for the few minutes it takes to boil a kettle. 2.2kW kettles would be a major drain on productivity: millions of extra minutes spent every day waiting for a cup of tea!
- Symbiote 2y agoI think 13A continuous draw is OK, as 3kW electric heaters are widely available: https://www.dimplex.co.uk/products/portable-heating/convector-heaters/ml3tstie7-3kw-convector-heater https://www.dimplex.co.uk/products/portable-heating/convecto... Perhaps electric cars limit their draw below 13A as they're much more likely to be connected using extension leads.
- gmac 2y agoYou would certainly hope that selling 3kW heaters was an indication of that, and that's what I used to think, but what I've read about EV charging makes me think that it isn't.
- chipsa 2y agoMost electric circuits are not rated for continuous load at rated power. The US nominal 15A circuit can only supply 12A continuous. Thus heaters of all types and EV charging being limited to about 1.5kW.