3 ms·
> admit I don't fully understand what the advantage of this project is against other work Replying to myself here; seems that the combination of being ex vivo
by gorkish 2y ago
> admit I don't fully understand what the advantage of this project is against other work
Replying to myself here; seems that the combination of being ex vivo and 7T means that the resolution increase over a typical in vivo patient scan is really really tremendous since your dead brain is happy to remain completely still through multi-hour sequences. The resolution you can get is primarily dependent on field strength but like many things in signal processing, you can trade integration time for higher resolution to a point. So this dataset is at about 100micron while 7T in vivo can only get down to maybe 300-1000micron (best case depending on patient movement)