2 ms·
Not anymore. All new receptacles in the US have a protection that will not allow you to insert anything into just one side. You have to insert prongs into both
by ars 14y ago
Not anymore. All new receptacles in the US have a protection that will not allow you to insert anything into just one side.
You have to insert prongs into both sides of the outlet at the same time in order for it to release.
http://en.wikipedia.org/wiki/NEMA_5-15#Tamper-resistant_receptacles http://en.wikipedia.org/wiki/NEMA_5-15#Tamper-resistant_rece...
- marshray 14y agoI've never seen one of these things, not even at Home Depot.
- ars 14y agoLook again - I had a hard time finding anything else last time I went. They are labeled with "TR". (There is also WR for water resistant, and of course TR and WR together, sigh. Prices are going up since now stores need to stock 4 times as many types.)
- btgeekboy 14y agoThey exist, but they sell them alongside the normal ones at an additional cost.
- icarus_drowning 14y agoI live in an older home (1955), but when we bought it in 2010 we had the original owner do electric work that had failed inspection-- as a result (and due to the local laws here), this is the only kind of socket we have.
- brudgers 14y agoThe change is in NFPA 70 - 2008, also known as "The National Electrical Code." The requirement only applies to dwellings (houses and apartments, not hotels or other commercial buildings), and only in jurisdictions which have adopted the 2008 NEC - the United States, unlike Canada does not have a national building code. In addition, many jurisdictions have adopted the International Residential Code for One and Two Family Dwellings (aka, "IRC) which contains its own electrical requirements. While their is provision for tamper resistant receptacles in the 2009 IRC, many jurisdictions have remained on older versions of that code because the 2009 edition requires fire sprinklers in single family homes and therefore its adoption creates substantial political tension between building departments and the homebuilders whose fees fund those departments. To put it another way, in the US, tamper resistant receptacles are not required in any non-residential structure, and because codes are adopted at the local or state level on an ad hoc basis, many dwellings are not required to conform with NEC 2008 or later versions. Think of new editions of building codes like Windows, lots of people still use XP.