3 ms·
A significant advantage of a higher temperature reactor would be if it could use the same steam turbines used in combined cycle plants. These are "dry" turbin
by pfdietz 3y ago
A significant advantage of a higher temperature reactor would be if it could use the same steam turbines used in combined cycle plants. These are "dry" turbines that operate with high temperature (550 C) steam. In contrast, LWRs use "wet" turbines with saturated steam at temperature a couple of hundred degrees lower. They're about the only ones still doing so, I think, so the turbines are bespoke and do not benefit from the economies of scale of the CC steam turbines.
(550 C is the upper temperature limit for cheap steel against creep, so I think that choice of temperature is not a coincidence. It also makes me dubious of reactor concepts operating at higher temperature.)