4 ms·
I have no external heat recovery system, so yes it's exactly zero while I'm cooking - but a reasonable way to maintain air quality in an open plan, one of my go
by mrspuratic 3y ago
I have no external heat recovery system, so yes it's exactly zero while I'm cooking - but a reasonable way to maintain air quality in an open plan, one of my goals.
The house also has new external wall insulation and other upgrades, so it's rather more airtight than before (though not formally tested just yet). Otherwise they run in synchronised cycle mode for heat recovery and air movement.
I'm not well versed in all the subtleties of theory and current technology, but I don't think regenerative and true ERV go together. If condensation forms in the unit on the exhaust cycle I'd guess does contribute a little to the recovered heat?
These units are BSK Zephyrs, with one heat mass component (ceramic honeycomb) and one fan inline in a telescopic duct. To prevent condensation issues they are fitted with a 2° slope outwards, and a humidity sensor with settable thresholds to purge high humidity internal air at full rate (equivalent to about 1.2 air changes/h for me).